Unterluggauer, Tim, Hipolito, F., Klyapovskiy, Sergey, Andersen, Peter Bach · 2022 · World Electric Vehicle Journal

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index; 5 of the 24 sources its claims cite were checked for support.

Abstract

The uptake of electric vehicles (EVs) may pose a challenge to power distribution networks (PDNs). While smart charging can be deployed to relieve stress on the grid, user-centric smart charging strategies could also exacerbate peak power demand due to synchronization when optimizing charging with regard to different objectives, such as charging costs. In this paper, we assess the charging demand emerging from a large fleet of EVs, with models for the decision to charge and distribution of the steady-state state-of-charge (SoC). These are applied to the municipality of Frederiksberg, Denmark, using data from the Danish national travel survey. Home and workplace charging are mapped to the urban 10 kV medium voltage PDN of Frederiksberg considering different charging behaviors and degrees of synchronization. Results indicate that the likelihood of severe congestion in the power distribution network is low and that it can be attributed to rare scenarios in which high synchronization is observed, particularly when maintaining the normal steady-state demand. Despite the low likelihood, preventive measures should be devised to mitigate such scenarios, especially if additional high-power consumers are connected.

Overview

CoChat Summary

TL;DR

This paper assesses how synchronized EV charging could affect the urban 10 kV medium-voltage distribution network of Frederiksberg, Denmark, using travel-survey-based charging demand and five charging scenarios. It finds severe congestion is unlikely except in rare high-synchronization scenarios, especially daily or time-and-day-synchronized charging.

Key findings

  • Uncontrolled charging did not pose a major concern: the coincidence factor did not exceed 13% at home and 27% at work, and scenarios S1–S3 increased peak load by less than 32%.
  • High synchronization with non-daily charging also had low impact, with CF below 24% for both home and workplace charging.
  • Rare daily time-synchronized or time-and-day-synchronized scenarios produced CF up to 95% and peak-load increases of roughly 183%, 100%, 215%, and 157% in S4a, S4b, S5a, and S5b, respectively.
  • Transformer overloading was the primary concern; no voltage violations were detected, and the worst cases implied overloading risk of up to 63% of transformers and 11% of cables, with reinforcement costs up to 8103 ke in S5a.

Methods

  • The study modelled five charging scenarios: S1 uncontrolled non-daily, S2 uncontrolled daily, S3 time-synchronized non-daily, S4 time-synchronized daily, and S5 time-and-day-synchronized non-daily, with home sub-scenarios a (midnight) and b (18:00) and workplace synchronization at 10:00.
  • EV demand was derived from Danish national travel survey records for 2006–2019, assuming full electrification of Frederiksberg’s 24,252 private cars and 59,070 daily EVs including 34,818 visitors, with 11 kW AC charging and 40 peak-load weekdays simulated.
  • The 10 kV Frederiksberg PDN was modelled in Pandapower using DSO Radius topology and hourly baseload interpolated to 15 min; Newton-Raphson power flow assessed transformer/cable loading above 75% and 100%, voltage, and reinforcement costs using 133 ke/km for cable and 21.64 ke for transformer replacements.

Limitations

  • The paper states that assuming all EV owners with good parking install chargers likely overestimates home and workplace charging, so results are upper bounds; it also notes that all users are assumed to follow the same charging behaviour, public charging is excluded, only normal weekdays are analysed, present-day vehicle numbers and distances are used, EV spot-market effects are neglected, and low-voltage constraints may dampen medium-voltage impacts.
  • Evident from the methods: travel records come from conventional vehicles because EV records were scarce, battery capacity is assumed at a mean of 68 kWh with standard deviation 18 kWh, charging power is fixed at 11 kW regardless of SoC, reactive power of EV charging is neglected, and vehicles are forced to complete charging even when parking durations are insufficient.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.3390/wevj13100182

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Methodology of the paper to determine the impact of different charging strategies on the power distribution network of Frederiksberg (FRB). While dark-gray-shaded rhomboids depict the input data, gray-shaded shapes represent the external parameter. The light-gray-shaded hexagon represents the external models [35] used in this work. White-shaded rectangles illustrate results obtained in each step of the process.
Figure 1 Methodology of the paper to determine the impact of different charging strategies on the power distribution network of Frederiksberg (FRB). While dark-gray-shaded rhomboids depict the input data, gray-shaded shapes represent the external parameter. The light-gray-shaded hexagon represents the external models [35] used in this work. White-shaded rectangles illustrate results obtained in each step of the process.CC-BY · From the PDF
Figure 2 Visualization of the urban power distribution network of Frederiksberg. The grid topology is shown on the footprint of the municipality, with gray lines indicating roads and walking paths and buildings represented in light blue. The 10/0.4 kV transformers i = {1, 2, 3} are illustrated by red, blue, and black solid dots. Medium voltage underground cables for all PDNs are shown in green.
Figure 2 Visualization of the urban power distribution network of Frederiksberg. The grid topology is shown on the footprint of the municipality, with gray lines indicating roads and walking paths and buildings represented in light blue. The 10/0.4 kV transformers i = {1, 2, 3} are illustrated by red, blue, and black solid dots. Medium voltage underground cables for all PDNs are shown in green.CC-BY · From the PDF
Figure 3 Representation of the segmentation of travel records according to residency and workplace municipality, as well as the parking conditions at the respective locations.
Figure 3 Representation of the segmentation of travel records according to residency and workplace municipality, as well as the parking conditions at the respective locations.CC-BY · From the PDF
Figure 4 Visualization of the municipality of Frederiksberg, with gray lines indicating roads and walking paths, and buildings represented in light blue. The identified residential housing areas with predominantly single-family houses are highlighted with a yellow shade, and the primary workplace parking areas are represented in a purple shade.
Figure 4 Visualization of the municipality of Frederiksberg, with gray lines indicating roads and walking paths, and buildings represented in light blue. The identified residential housing areas with predominantly single-family houses are highlighted with a yellow shade, and the primary workplace parking areas are represented in a purple shade.CC-BY · From the PDF
Figure 5 Charging event allocation methodology. Dark-gray-shaded rhomboids indicate the input data, and white-shaded rectangles illustrate the results obtained in each step of the process.
Figure 5 Charging event allocation methodology. Dark-gray-shaded rhomboids indicate the input data, and white-shaded rectangles illustrate the results obtained in each step of the process.CC-BY · From the PDF
Image 6
CC-BY · From the PDF
Figure 7 Aggregated active power demand of all three power distribution networks in Frederiksberg, illustrated from 05:00 on 6 January 2020 to 04:45 on 7 January 2020. While the black plot indicates the aggregated baseload, the aggregated demand (comprising both baseload and EV load) is illustrated by different colors for each charging scenario.
Figure 7 Aggregated active power demand of all three power distribution networks in Frederiksberg, illustrated from 05:00 on 6 January 2020 to 04:45 on 7 January 2020. While the black plot indicates the aggregated baseload, the aggregated demand (comprising both baseload and EV load) is illustrated by different colors for each charging scenario.CC-BY · From the PDF
Image 8
CC-BY · From the PDF

Verification

Claims the paper makes

5 Valid · 1 Not valid · 11 Not checked · 67 Own results and interpretations

46 more claims

Create a free account to see all 84 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 25
  • It may state two separate claims as one. 11

Create a free account to see these claims.

Citations

Cites

Cited by

See all 20

Metadata

Authors
Unterluggauer, T., Hipolito, F., Klyapovskiy, S., & Andersen, P. B.
Affiliations
  • Technical University of Denmark (DK)
  • Department of Management Engineering, Technical University of Denmark, 2800 Kongens Lyngby, Denmark
Corresponding author
Unterluggauer, Tim
Venue
World Electric Vehicle Journal
Publisher
MDPI AG
Published
2022-09-30
Volume
13
Issue
10
Pages
182
ISSN
2032-6653 (ISSN-L)
OpenAlex
W4304690771
Cited by
20
References
27
Citations by year
2026: 4 · 2025: 8 · 2024: 4 · 2023: 3 · 2022: 1
FWCI
1.10
Type
journal article
Language
en
Open access
Locations
  • World Electric Vehicle Journal (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU) (submittedVersion, cc-by)
Funders
FUSE (64020-1092)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Vehicles and Infrastructure
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Smart Grid Energy Management
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
Keywords
electric vehicle charging, urban power grid, peak load, state of charge, charging behavior, grid congestion, Frederiksberg

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-02, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-02 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.