Type and accuracy of sphygmomanometers in primary care: a cross-sectional observational study

Open access
A'Court, Christine, Stevens, Richard, Sanders, Sarah, Ward, Alison, McManus, Richard, Heneghan, Carl · 2011 · British Journal of General Practice
Cited by 59

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Previous studies identified worrying levels of sphygmomanometer inaccuracy and have not been repeated in the era of digital measurement of blood pressure. AIM: To establish the type and accuracy of sphygmomanometers in current use. DESIGN AND SETTING: Cross-sectional, observational study in 38 Oxfordshire primary care practices. METHOD: Sphygmomanometers were evaluated between 50 and 250 mmHg, using Omron PA350 or Scandmed 950831-2 pressure meters. RESULTS: Six hundred and four sphygmomanometers were identified: 323 digital (53%), 192 aneroid (32%), 79 mercury (13%), and 10 hybrid (2%) devices. Of these, 584 (97%) could be fully tested. Overall, 503/584 (86%) were within 3 mmHg of the reference, 77/584 (13%) had one or more error of 4-9 mmHg, and 4/584 (<1%) had one or more error of more than 10 mmHg. Mercury (71/75, 95%) and digital (272/308, 88%) devices were more likely to be within 3 mmHg of the reference standard than aneroid models (150/191, 78%) (Fisher's exact test P = 0.001). Donated aneroid devices from the pharmaceutical industry performed significantly worse: 10/23 (43%) within 3 mmHg of standard compared to 140/168 (83%) aneroid models from recognised manufacturers (Fisher's exact test P<0.001). No significant difference was found in performance between manufacturers within each device type, for either aneroid (Fisher's exact test P = 0.96) or digital (Fisher's exact test P = 0.7) devices. CONCLUSION: Digital sphygmomanometers have largely replaced mercury models in primary care and have equivalent accuracy. Aneroid devices have higher failure rates than other device types; this appears to be largely accounted for by models from indiscernible manufacturers. Given the availability of inexpensive and accurate digital models, GPs could consider replacing aneroid devices with digital equivalents, especially for home visiting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3399/bjgp11x593884

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 59

Metadata

Authors
A'Court, C., Stevens, R., Sanders, S., Ward, A., McManus, R., & Heneghan, C.
Venue
British Journal of General Practice
Published
2011-09
Volume
61
Issue
590
Pages
e598-e603
ISSN
  • 0960-1643 (ISSN-L)
  • 1478-5242
OpenAlex
W2047236409
Cited by
59
References
1
FWCI
2.05
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Type and accuracy of sphygmomanometers in primary care: a cross-sectional observational study. https://app.cochat.ai/papers/10.3399/bjgp11x593884
The paper
A'Court, C., Stevens, R., Sanders, S., Ward, A., McManus, R., & Heneghan, C. (2011). Type and accuracy of sphygmomanometers in primary care: a cross-sectional observational study. British Journal of General Practice. https://doi.org/10.3399/bjgp11x593884

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.