CoChat

The urgency to regulate validation of automated blood pressure measuring devices: a policy statement and call to action from the world hypertension league

Open access

The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.

Abstract

This policy statement is intended to be used as a resource for all health professionals and civil society, including regulatory agencies, Ministries of Health and healthcare organizations, to accelerate the availability, affordability, and exclusive use of automated blood pressure measuring devices (BPMDs) that have passed adequate clinical validation testing. In line with guidance from the World Health Organization (WHO) medical device technical series [ 1 ], the term clinical validation is the process by which devices are tested for accuracy in healthy people and patients with hypertension, and a clinically validated BPMD is one that has “undergone rigorous, standardized testing against a gold standard [properly calibrated manual auscultatory measurement] to ensure that the device produces accurate measurements” [ 1 ] to an internationally accepted standard.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41371-022-00747-0

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 42 references

Cited by

See all 36

Metadata

Authors
Sharman, J. E., Ordunez, P., Brady, T., Parati, G., Stergiou, G., Whelton, P. K., Padwal, R., Olsen, M. H., Delles, C., Schutte, A. E., Tomaszewski, M., Lackland, D. T., Khan, N., McManus, R. J., Tsuyuki, R. T., Zhang, X.-H., Murphy, L. D., Moran, A. E., Schlaich, M. P., & Campbell, N. R. C.
Affiliations
  • University of Tasmania (AU)
  • Johns Hopkins University (US)
  • IRCCS Istituto Auxologico Italiano (IT)
  • National and Kapodistrian University of Athens (GR)
  • Tulane University (US)
  • University of Alberta (CA)
  • University of Southern Denmark (DK)
  • University of Glasgow (GB)
  • UNSW Sydney (AU)
  • Manchester Academic Health Science Centre (GB)
  • Medical University of South Carolina (US)
  • University of British Columbia (CA)
  • University of Oxford (GB)
  • Hypertension Canada (CA)
  • National Stroke Foundation (AU)
  • Resolve to Save Lives (US)
  • The University of Western Australia (AU)
  • University of Calgary (CA)
Corresponding author
Sharman, James E.
Venue
Journal of Human Hypertension
Published
2022-12-07
Volume
37
Issue
2
Pages
155-159
ISSN
  • 0950-9240 (ISSN-L)
  • 1476-5527
OpenAlex
W4310942115
Cited by
31
References
42
Citations by year
2026: 6 · 2025: 8 · 2024: 11 · 2023: 5 · 2022: 1
FWCI
1.27
Type
journal article
Language
en
Open access
Licence
Locations
  • Journal of Human Hypertension (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • ENLIGHTEN (Jurnal Bimbingan dan Konseling Islam) (submittedVersion, cc-by-nc-sa)
  • University of Southern Denmark Research Portal (University of Southern Denmark) (submittedVersion, cc-by-nc-sa)
  • Figshare (submittedVersion, cc-by)
  • UWA Profiles and Research Repository (UWA) (submittedVersion, cc-by)
  • Research Explorer (The University of Manchester) (submittedVersion, cc-by)
Funders
  • International Society of Hypertension
  • National Institute for Health and Care Research (NIHR200201, NIHR205071)
  • High Blood Pressure Research Council of Australia
  • Hypertension Canada
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Healthcare Regulation
Keywords
clinical validation, medical device regulation, hypertension, blood pressure measurement accuracy
MeSH terms
Blood Pressure, Blood Pressure Determination, Humans, Hypertension, Policy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The urgency to regulate validation of automated blood pressure measuring devices: a policy statement and call to action from the world hypertension league. https://app.cochat.ai/papers/10.1038/s41371-022-00747-0
The paper
Sharman, J. E., Ordunez, P., Brady, T., Parati, G., Stergiou, G., Whelton, P. K., Padwal, R., Olsen, M. H., Delles, C., Schutte, A. E., Tomaszewski, M., Lackland, D. T., Khan, N., McManus, R. J., Tsuyuki, R. T., Zhang, X.-H., Murphy, L. D., Moran, A. E., Schlaich, M. P., & Campbell, N. R. C. (2022). The urgency to regulate validation of automated blood pressure measuring devices: a policy statement and call to action from the world hypertension league. Journal of Human Hypertension. https://doi.org/10.1038/s41371-022-00747-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.