Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 190

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Comparative analysis of EV isolation procedures for miRNAs detection in serum samples

Open access
Andreu, Zoraida, Rivas, Eva, Sanguino‐Pascual, Aitana, Lamana, Amalia, Marazuela, Mónica, González‐Alvaro, Isidoro, Sánchez‐Madrid, Francisco, de la Fuente, Hortensia, Yáñez‐Mó, María·2016·Journal of Extracellular Vesicles

Abstract

Extracellular vesicles (EVs) are emerging as potent non‐invasive biomarkers. However, current methodologies are time consuming and difficult to translate to clinical practice. To analyse EV‐encapsulated circulating miRNA, we searched for a quick, easy and economic method to enrich frozen human serum samples for EV. We compared the efficiency of several protocols and commercial kits to isolate EVs. Different methods based on precipitation, columns or filter systems were tested and compared with ultracentrifugation, which is the most classical protocol to isolate EVs. EV samples were assessed for purity and quantity by nanoparticle tracking analysis and western blot or cytometry against major EV protein markers. For biomarker validation, levels of a set of miRNAs were determined in EV fractions and compared with their levels in total serum. EVs isolated with precipitation‐based methods were enriched for a subgroup of miRNAs that corresponded to miRNAs described to be encapsulated into EVs (miR‐126, miR‐30c and miR‐143), while the detection of miR‐21, miR‐16‐5p and miR‐19a was very low compared with total serum. Our results point to precipitation using polyethylene glycol (PEG) as a suitable method for an easy and cheap enrichment of serum EVs for miRNA analyses. The overall performance of PEG was very similar, or better than other commercial precipitating reagents, in both protein and miRNA yield, but in comparison to them PEG is much cheaper. Other methods presented poorer results, mostly when assessing miRNA by qPCR analyses. Using PEG precipitation in a longitudinal study with human samples, we demonstrated that miRNA could be assessed in frozen samples up to 8 years of storage. We report a method based on a cut‐off value of mean of fold EV detection versus serum that provides an estimate of the degree of encapsulation of a given miRNA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3402/jev.v5.31655

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 190

Metadata

Authors
Andreu, Z., Rivas, E., Sanguino‐Pascual, A., Lamana, A., Marazuela, M., González‐Alvaro, I., Sánchez‐Madrid, F., de la Fuente, H., & Yáñez‐Mó, M.
Venue
Journal of Extracellular Vesicles
Publisher
Wiley
Published
2016-01
Volume
5
Issue
1
Pages
31655-31655
ISSN
2001-3078 (ISSN-L)
OpenAlex
W2464767991
Cited by
190
References
2
FWCI
7.37
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.