Variation of system performance, quality control standards and adherence to international FDG-PET/CT imaging guidelines: A national survey of PET/CT operations in Austria
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Summary: Aim: To gather information on clinical operations, quality control (QC) standards and adoption of guidelines for FDG-PET/CT imaging in Austrian PET/CT centres. Methods: A written survey composed of 68 questions related to A) PET/CT centre and installation, B) standard protocol parameters for FDG-PET/CT imaging of oncology patients, and C) standard QC procedures was conducted between November and December 2013 among all Austrian PET/CT centres. In addition, a NEMA-NU2 2012 image quality phantom test was performed using standard whole-body imaging settings on all PET/CT systems with a lesion-to- background ratio of 4. Recovery coefficients (RC) were calculated for each lesion and PET/ CT system. Resu lts: A) 13 PET/CT systems were installed in 12 nuclear medicine departments at public hospitals. B) Average fasting prior to FDG-PET/CT was 7.6 (4-12) h. All sites measured blood glucose levels while using different cut-off levels (64%: 150 mg/dl). Weight- based activity injection was performed at 83% sites with a mean FDG activity of 4.1 MBq/kg. Average FDG uptake time was 55 (45-75) min. All sites employed CT contrast agents (variation from 1 %-95% of the patients). All sites reported SUV-max. C) Frequency of QC tests varied significantly and QC phantom measurements revealed significant differences in RCs. Conclusion: Significant variations in FDG-PET/CT protocol parameters among all Austrian PET/CT users were observed. subsequently, efforts need to be put in place to further standardize imaging protocols. At a minimum clinical PET/CT operations should ensure compliance with existing guidelines. Further, standardized QC procedures must be followed to improve quantitative accuracy across PET/CT centres.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stewart, F. A., Akleyev, A. V., Hauer-Jensen, M., Hendry, J. H., Kleiman, N. J., MacVittie, T. J., Aleman, B. M., Edgar, A. B., Mabuchi, K., Muirhead, C. R., et al. (2012) · Annals of the ICRP · doi:10.1016/j.icrp.2012.02.001 · Cited by 1,604
PET/CT with intravenous contrast can be used for PET attenuation correction in cancer patients
Berthelsen, A. K., Holm, S., Loft, A., Klausen, T. L., Andersen, F., & Højgaard, L. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-1784-1 · Cited by 151
Variations in Clinical PET/CT Operations: Results of an International Survey of Active PET/CT Users
Beyer, T., Czernin, J., & Freudenberg, L. S. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.079624 · Cited by 136
Self-citationAschoff, P., Plathow, C., Beyer, T., Lichy, M. P., Erb, G., Öksüz, M. Ö., Claussen, C. D., & Pfannenberg, C. (2012) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-1919-5 · Cited by 29
Self-citation
Cited by
Aide, N., Lasnon, C., Veit-Haibach, P., Sera, T., Sattler, B., & Boellaard, R. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3740-2 · Cited by 344
Performance Evaluation of the Vereos PET/CT System According to the NEMA NU2-2012 Standard
Rausch, I., Ruiz, A., Valverde-Pascual, I., Cal-González, J., Beyer, T., & Carrio, I. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.215541 · Cited by 168
Self-citationRausch, I., Cal-González, J., Dapra, D., Gallowitsch, H. J., Lind, P., Beyer, T., & Minear, G. (2015) · EJNMMI Physics · doi:10.1186/s40658-015-0132-1 · Cited by 133
“National Institutes of Health, Bethesda, Maryland, USA), which had been previously validated and used during two Austrian PET Inter-Laboratory comparison studies [26, 27].”
MethodSelf-citationQuak, E., Le Roux, P.-Y., Hofman, M. S., Robin, P., Bourhis, D., Callahan, J., Binns, D., Desmonts, C., Salaun, P.-Y., Hicks, R. J., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3128-0 · Cited by 107
Metadata
- Authors
- Bergmann, H., Geist, B., Schaffarich, M., Hirtl, A., Hacker, M., Beyer, T., & Rausch, I.
- Venue
- Nuklearmedizin
- Publisher
- Georg Thieme Verlag KG
- Published
- 2014
- Volume
- 53
- Issue
- 06
- Pages
- 242-248
- ISSN
- 0029-5566 (ISSN-L)
- 2567-6407
- OpenAlex
- W1743906782
- Cited by
- 33
- References
- 4
- FWCI
- 3.61
- Type
- journal article
- Language
- de
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Variation of system performance, quality control standards and adherence to international FDG-PET/CT imaging guidelines: A national survey of PET/CT operations in Austria. https://app.cochat.ai/papers/10.3413/nukmed-0665-14-05
- The paper
- Bergmann, H., Geist, B., Schaffarich, M., Hirtl, A., Hacker, M., Beyer, T., & Rausch, I. (2014). Variation of system performance, quality control standards and adherence to international FDG-PET/CT imaging guidelines: A national survey of PET/CT operations in Austria. Nuklearmedizin. https://doi.org/10.3413/nukmed-0665-14-05
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.