Smart Medical Information Technology for Healthcare (SMITH): Data Integration based on Interoperability Standards
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Summary: Introduction: This article is part of the Focus Theme of Methods of Information in Medicine on the German Medical Informatics Initiative. “Smart Medical Information Technology for Healthcare (SMITH)” is one of four consortia funded by the German Medical Informatics Initiative (MI-I) to create an alliance of universities, university hospitals, research institutions and IT companies. SMITH’s goals are to establish Data Integration Centers (DICs) at each SMITH partner hospital and to implement use cases which demonstrate the usefulness of the approach. Objectives: To give insight into architectural design issues underlying SMITH data integration and to introduce the use cases to be implemented. Governance and Policies: SMITH implements a federated approach as well for its governance structure as for its information system architecture. SMITH has designed a generic concept for its data integration centers. They share identical services and functionalities to take best advantage of the interoperability architectures and of the data use and access process planned. The DICs provide access to the local hospitals’ Electronic Medical Records (EMR). This is based on data trustee and privacy management services. DIC staff will curate and amend EMR data in the Health Data Storage. Methodology and Architectural Framework: To share medical and research data, SMITH’s information system is based on communication and storage standards. We use the Reference Model of the Open Archival Information System and will consistently implement profiles of Integrating the Health Care Enterprise (IHE) and Health Level Seven (HL7) standards. Standard terminologies will be applied. The SMITH Market Place will be used for devising agreements on data access and distribution. 3LGM2 for enterprise architecture modeling supports a consistent development process. The DIC reference architecture determines the services, applications and the standards-based communication links needed for efficiently supporting the ingesting, data nourishing, trustee, privacy management and data transfer tasks of the SMITH DICs. The reference architecture is adopted at the local sites. Data sharing services and the market place enable interoperability. Use Cases: The methodological use case “Phenotype Pipeline” (PheP) constructs algorithms for annotations and analyses of patient-related phenotypes according to classification rules or statistical models based on structured data. Unstructured textual data will be subject to natural language processing to permit integration into the phenotyping algorithms. The clinical use case “Algorithmic Surveillance of ICU Patients” (ASIC) focusses on patients in Intensive Care Units (ICU) with the acute respiratory distress syndrome (ARDS). A model-based decision-support system will give advice for mechanical ventilation. The clinical use case HELP develops a “hospital-wide electronic medical record-based computerized decision support system to improve outcomes of patients with blood-stream infections” (HELP). ASIC and HELP use the PheP. The clinical benefit of the use cases ASIC and HELP will be demonstrated in a change of care clinical trial based on a step wedge design. Discussion: SMITH’s strength is the modular, reusable IT architecture based on interoperability standards, the integration of the hospitals’ information management departments and the public-private partnership. The project aims at sustainability beyond the first 4-year funding period.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The FAIR Guiding Principles for scientific data management and stewardship
Wilkinson, M. D., Dumontier, M., Aalbersberg, I. J., Appleton, G., Axton, M., Baak, A., Blomberg, N., Boiten, J.-W., da Silva Santos, L. B., Bourne, P. E., et al. (2016) · Scientific Data · doi:10.1038/sdata.2016.18 · Cited by 18,423
George, H., Duke Jon, D., Shah Nigam, H., Reich Christian, G., Vojtech, H., Schuemie Martijn, J., Suchard Marc, A., Woong, P. R., Kei, W. I. C., Rijnbeek Peter, R., et al. (2015) · Studies in Health Technology and Informatics · doi:10.3233/978-1-61499-564-7-574 · Cited by 1,542
A targeted real-time early warning score (TREWScore) for septic shock.
Henry, K. E., Hager, D. N., Pronovost, P. J., & Saria, S. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aab3719 · Cited by 598 · cited 1×
“4% of all patients requiring mechanical ventilation [35].”
Gruendner, J., Schwachhofer, T., Sippl, P., Wolf, N., Erpenbeck, M., Gulden, C., Kapsner, L. A., Zierk, J., Mate, S., Stürzl, M., et al. (2019) · PLOS ONE · doi:10.1371/journal.pone.0223010 · Cited by 54
Cited by
Medical 4.0 technologies for healthcare: Features, capabilities, and applications
Haleem, A., Javaid, M., Pratap Singh, R., & Suman, R. (2022) · Internet of Things and Cyber-Physical Systems · doi:10.1016/j.iotcps.2022.04.001 · Cited by 468
Interoperability of heterogeneous health information systems: a systematic literature review
Torab-Miandoab, A., Samad-Soltani, T., Jodati, A., & Rezaei-Hachesu, P. (2023) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-023-02115-5 · Cited by 393
Maassen, O., Fritsch, S., Palm, J., Deffge, S., Kunze, J., Marx, G., Riedel, M., Schuppert, A., & Bickenbach, J. (2021) · Journal of Medical Internet Research · doi:10.2196/26646 · Cited by 125
“Four consortia (Smart Medical Information Technology for Healthcare [SMITH] [76], Medical Informatics in Research and Care in University Medicine [MIRACUM] [77], HiGHmed [78], and Data Integration for Future Medicine [DIFUTURE] [79]) that include all German university hospitals are conceptualizing, developing, and ope…”
BackgroundSelf-citationGruendner, J., Schwachhofer, T., Sippl, P., Wolf, N., Erpenbeck, M., Gulden, C., Kapsner, L. A., Zierk, J., Mate, S., Stürzl, M., et al. (2019) · PLOS ONE · doi:10.1371/journal.pone.0223010 · Cited by 54
Metadata
- Authors
- Winter, A., Stäubert, S., Ammon, D., Aiche, S., Beyan, O., Bischoff, V., Daumke, P., Decker, S., Funkat, G., Gewehr, J., de Greiff, A., Haferkamp, S., Hahn, U., Henkel, A., Kirsten, T., Klöss, T., Lippert, J., Löbe, M., Lowitsch, V., Maassen, O., Maschmann, J., Meister, S., Mikolajczyk, R., Nüchter, M., Pletz, M., Rahm, E., Riedel, M., Saleh, K., Schuppert, A., Smers, S., Stollenwerk, A., Uhlig, S., Wendt, T., Zenker, S., Fleig, W., Marx, G., Scherag, A., & Löffler, M.
- Venue
- Methods of Information in Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 2018-07
- Volume
- 57
- Issue
- S 01
- Pages
- e92-e105
- ISSN
- 0026-1270 (ISSN-L)
- 2511-705X
- OpenAlex
- W2894794416
- Cited by
- 130
- References
- 4
- FWCI
- 15.10
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Smart Medical Information Technology for Healthcare (SMITH): Data Integration based on Interoperability Standards. https://app.cochat.ai/papers/10.3414/me18-02-0004
- The paper
- Winter, A., Stäubert, S., Ammon, D., Aiche, S., Beyan, O., Bischoff, V., Daumke, P., Decker, S., Funkat, G., Gewehr, J., de Greiff, A., Haferkamp, S., Hahn, U., Henkel, A., Kirsten, T., Klöss, T., Lippert, J., Löbe, M., Lowitsch, V., . . . Löffler, M. (2018). Smart Medical Information Technology for Healthcare (SMITH): Data Integration based on Interoperability Standards. Methods of Information in Medicine. https://doi.org/10.3414/me18-02-0004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.