CoChat

Smart Medical Information Technology for Healthcare (SMITH): Data Integration based on Interoperability Standards

Open access
Winter, Alfred, Stäubert, Sebastian, Ammon, Danny, Aiche, Stephan, Beyan, Oya, Bischoff, Verena, Daumke, Philipp, Decker, Stefan, Funkat, Gert, Gewehr, Jan, de Greiff, Armin, Haferkamp, Silke, Hahn, Udo, Henkel, Andreas, Kirsten, Toralf, Klöss, Thomas, Lippert, Jörg, Löbe, Matthias, Lowitsch, Volker, Maassen, Oliver, Maschmann, Jens, Meister, Sven, Mikolajczyk, Rafael, Nüchter, Matthias, Pletz, Mathias, Rahm, Erhard, Riedel, Morris, Saleh, Kutaiba, Schuppert, Andreas, Smers, Stefan, Stollenwerk, André, Uhlig, Stefan, Wendt, Thomas, Zenker, Sven, Fleig, Wolfgang, Marx, Gernot, Scherag, André, Löffler, Markus · 2018 · Methods of Information in Medicine
Cited by 130

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Summary: Introduction: This article is part of the Focus Theme of Methods of Information in Medicine on the German Medical Informatics Initiative. “Smart Medical Information Technology for Healthcare (SMITH)” is one of four consortia funded by the German Medical Informatics Initiative (MI-I) to create an alliance of universities, university hospitals, research institutions and IT companies. SMITH’s goals are to establish Data Integration Centers (DICs) at each SMITH partner hospital and to implement use cases which demonstrate the usefulness of the approach. Objectives: To give insight into architectural design issues underlying SMITH data integration and to introduce the use cases to be implemented. Governance and Policies: SMITH implements a federated approach as well for its governance structure as for its information system architecture. SMITH has designed a generic concept for its data integration centers. They share identical services and functionalities to take best advantage of the interoperability architectures and of the data use and access process planned. The DICs provide access to the local hospitals’ Electronic Medical Records (EMR). This is based on data trustee and privacy management services. DIC staff will curate and amend EMR data in the Health Data Storage. Methodology and Architectural Framework: To share medical and research data, SMITH’s information system is based on communication and storage standards. We use the Reference Model of the Open Archival Information System and will consistently implement profiles of Integrating the Health Care Enterprise (IHE) and Health Level Seven (HL7) standards. Standard terminologies will be applied. The SMITH Market Place will be used for devising agreements on data access and distribution. 3LGM2 for enterprise architecture modeling supports a consistent development process. The DIC reference architecture determines the services, applications and the standards-based communication links needed for efficiently supporting the ingesting, data nourishing, trustee, privacy management and data transfer tasks of the SMITH DICs. The reference architecture is adopted at the local sites. Data sharing services and the market place enable interoperability. Use Cases: The methodological use case “Phenotype Pipeline” (PheP) constructs algorithms for annotations and analyses of patient-related phenotypes according to classification rules or statistical models based on structured data. Unstructured textual data will be subject to natural language processing to permit integration into the phenotyping algorithms. The clinical use case “Algorithmic Surveillance of ICU Patients” (ASIC) focusses on patients in Intensive Care Units (ICU) with the acute respiratory distress syndrome (ARDS). A model-based decision-support system will give advice for mechanical ventilation. The clinical use case HELP develops a “hospital-wide electronic medical record-based computerized decision support system to improve outcomes of patients with blood-stream infections” (HELP). ASIC and HELP use the PheP. The clinical benefit of the use cases ASIC and HELP will be demonstrated in a change of care clinical trial based on a step wedge design. Discussion: SMITH’s strength is the modular, reusable IT architecture based on interoperability standards, the integration of the hospitals’ information management departments and the public-private partnership. The project aims at sustainability beyond the first 4-year funding period.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3414/me18-02-0004

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 130

Metadata

Authors
Winter, A., Stäubert, S., Ammon, D., Aiche, S., Beyan, O., Bischoff, V., Daumke, P., Decker, S., Funkat, G., Gewehr, J., de Greiff, A., Haferkamp, S., Hahn, U., Henkel, A., Kirsten, T., Klöss, T., Lippert, J., Löbe, M., Lowitsch, V., Maassen, O., Maschmann, J., Meister, S., Mikolajczyk, R., Nüchter, M., Pletz, M., Rahm, E., Riedel, M., Saleh, K., Schuppert, A., Smers, S., Stollenwerk, A., Uhlig, S., Wendt, T., Zenker, S., Fleig, W., Marx, G., Scherag, A., & Löffler, M.
Venue
Methods of Information in Medicine
Published
2018-07
Volume
57
Issue
S 01
Pages
e92-e105
ISSN
  • 0026-1270 (ISSN-L)
  • 2511-705X
OpenAlex
W2894794416
Cited by
130
References
4
FWCI
15.10
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Smart Medical Information Technology for Healthcare (SMITH): Data Integration based on Interoperability Standards. https://app.cochat.ai/papers/10.3414/me18-02-0004
The paper
Winter, A., Stäubert, S., Ammon, D., Aiche, S., Beyan, O., Bischoff, V., Daumke, P., Decker, S., Funkat, G., Gewehr, J., de Greiff, A., Haferkamp, S., Hahn, U., Henkel, A., Kirsten, T., Klöss, T., Lippert, J., Löbe, M., Lowitsch, V., . . . Löffler, M. (2018). Smart Medical Information Technology for Healthcare (SMITH): Data Integration based on Interoperability Standards. Methods of Information in Medicine. https://doi.org/10.3414/me18-02-0004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.