The area-of-interest problem in eyetracking research: A noise-robust solution for face and sparse stimuli
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
A problem in eyetracking research is choosing areas of interest (AOIs): Researchers in the same field often use widely varying AOIs for similar stimuli, making cross-study comparisons difficult or even impossible. Subjective choices while choosing AOIs cause differences in AOI shape, size, and location. On the other hand, not many guidelines for constructing AOIs, or comparisons between AOI-production methods, are available. In the present study, we addressed this gap by comparing AOI-production methods in face stimuli, using data collected with infants and adults (with autism spectrum disorder [ASD] and matched controls). Specifically, we report that the attention-attracting and attention-maintaining capacities of AOIs differ between AOI-production methods, and that this matters for statistical comparisons in one of three groups investigated (the ASD group). In addition, we investigated the relation between AOI size and an AOI's attention-attracting and attention-maintaining capacities, as well as the consequences for statistical analyses, and report that adopting large AOIs solves the problem of statistical differences between the AOI methods. Finally, we tested AOI-production methods for their robustness to noise, and report that large AOIs-using the Voronoi tessellation method or the limited-radius Voronoi tessellation method with large radii-are most robust to noise. We conclude that large AOIs are a noise-robust solution in face stimuli and, when implemented using the Voronoi method, are the most objective of the researcher-defined AOIs. Adopting Voronoi AOIs in face-scanning research should allow better between-group and cross-study comparisons.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Attention to eyes is present but in decline in 2–6-month-old infants later diagnosed with autism
Jones, W., & Klin, A. (2013) · Nature · doi:10.1038/nature12715 · Cited by 1,293
Jones, W., Carr, K., & Klin, A. (2008) · Archives of General Psychiatry · doi:10.1001/archpsyc.65.8.946 · Cited by 650
Speech Disturbs Face Scanning in 6-Month-Old Infants Who Develop Autism Spectrum Disorder
Shic, F., Macari, S., & Chawarska, K. (2014) · Biological Psychiatry · doi:10.1016/j.biopsych.2013.07.009 · Cited by 221
Wass, S. V., Forssman, L., & Leppänen, J. (2014) · Infancy · doi:10.1111/infa.12055 · Cited by 146 · cited 1×
“Wass, Forssman, and Leppänen (2014) added Gaussian noise to raw data samples from infant eyetracking data to faces and reported that the distribution of total dwell times across the eyes, nose, and mouth (hand-drawn rectangle shaped AOIs) and the non-AOI region changed.”
de JONG, M. C., van ENGELAND, H., & KEMNER, C. (2008) · Journal of the American Academy of Child & Adolescent Psychiatry · doi:10.1097/chi.0b013e31816429a6 · Cited by 76 · cited 1×
“The stimuli were provided by de Jong, van Engeland, and Kemner (2008).”
Self-citation
Cited by
Best practices in eye tracking research
Carter, B. T., & Luke, S. G. (2020) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2020.05.010 · Cited by 659
Eye Movement and Pupil Measures: A Review
Mahanama, B., Jayawardana, Y., Rengarajan, S., Jayawardena, G., Chukoskie, L., Snider, J., & Jayarathna, S. (2022) · Frontiers in Computer Science · doi:10.3389/fcomp.2021.733531 · Cited by 307
Noise-robust fixation detection in eye movement data: Identification by two-means clustering (I2MC)
Hessels, R. S., Niehorster, D. C., Kemner, C., & Hooge, I. T. C. (2017) · Behavior Research Methods · doi:10.3758/s13428-016-0822-1 · Cited by 202
Self-citationEye tracking in human interaction: Possibilities and limitations
Valtakari, N. V., Hooge, I. T. C., Viktorsson, C., Nyström, P., Falck-Ytter, T., & Hessels, R. S. (2021) · Behavior Research Methods · doi:10.3758/s13428-020-01517-x · Cited by 161
Self-citationThe impact of slippage on the data quality of head-worn eye trackers
Niehorster, D. C., Santini, T., Hessels, R. S., Hooge, I. T. C., Kasneci, E., & Nyström, M. (2020) · Behavior Research Methods · doi:10.3758/s13428-019-01307-0 · Cited by 159
“…if the eye-tracking setup records gaze positions with a systematic offset that is too large to reliably distinguish which of two nearby objects of interest an observer looks at (Orquin & Holmqvist 2018; Hessels, Kemner, van den Boomen, & Hooge 2016), such as for instance different facial features.”
BackgroundSelf-citation
Metadata
- Authors
- Hessels, R. S., Kemner, C., van den Boomen, C., & Hooge, I. T. C.
- Venue
- Behavior Research Methods
- Published
- 2015-11-12
- Volume
- 48
- Issue
- 4
- Pages
- 1694-1712
- ISSN
- 1554-351X (ISSN-L)
- 1554-3528
- OpenAlex
- W2177526340
- Cited by
- 231
- References
- 5
- FWCI
- 5.16
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.