Use of Middle Ear Immittance Testing in the Evaluation of Patulous Eustachian Tube
The DOI matches its Crossref record.
Abstract
Background: Patulous Eustachian tube is the uncommon condition of a persistently open Eustachian tube, which causes the disturbing symptoms of autophony and respiratory-synchronous tinnitus. We review this condition and propose a specific evaluation protocol that can be performed quickly and easily using standard audiologic test equipment. We have used this protocol in the evaluation of a number of patients and will discuss our findings. Purpose: To establish a standardized protocol for the audiologic evaluation of patulous Eustachian tube using a standard clinical tympanometer and to establish norms with respect to tympanic membrane movement during breathing tasks. Research Design: Quantitative analysis of test results obtained during clinical evaluation of patients referred for suspected patulous Eustachian tube during 2008 and 2009. Study Sample: The cohort was 35 individuals including 25 patients referred for suspected patulous Eustachian tube and 10 control (normal) patients. Of the total group, 25 individuals were female, 10 were male, and the overall age range was 8 yr to 82 yr. Data Collection and Analysis: Patients underwent audiologic and otologic testing including quantitative measurement of middle ear compliance during breathing and nasal endoscopy. Two tympanometers were used to assess middle ear compliance: the Grason-Stadler Instruments Model 33 and Tympstar. Endoscopy was performed using either a Storz Endoskope Xenon Nova 175 or a Pentax EPM 1000. Results of middle ear immittance tests performed during breathing tasks were compared with results of endoscopy as well as the impressions of the examining physician. Magnitude of middle ear compliance was examined for mean and standard deviation, and the control/normal group results were compared with those of individuals complaining of symptoms suggestive of patulous Eustachian tube. Results: We found that slightly greater than 75% of individual ears with patulous Eustachian tube exhibited middle ear compliance greater than 0.07 ml during breathing tasks. All ears with patulous Eustachian tube exhibited a respiratory-synchronous compliance pattern during breathing tasks. Of individual ears without patulous Eustachian tube, 97% exhibited middle ear compliance during breathing of less than 0.07 ml with no respiratory-synchronous pattern. Conclusions: Measurement of middle ear compliance during breathing appears to be a sensitive and specific tool in the examination of patulous Eustachian tube, particularly when both the magnitude of compliance and the pattern of compliance are considered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While ipsilateral nostril breathing concentrates these pressure changes in the tested side and permits maximum increases in COT, nasal breathing will directly raise nasopharyngeal pressure [18]”
From Assessment of sensitivity of acoustic reflex decay test in diagnosis of patulous eustachian tube (2024) · cites this paper as [18]
In the citing paper
“The capacity of a tympanometer to graph the tympanic membrane's COT, sometimes referred to as long timebase tympanometry and often available on the reflex decay testing function in commercial tympanometers, is beneficial for the evaluation of ET function.”
From Assessment of sensitivity of acoustic reflex decay test in diagnosis of patulous eustachian tube (2024) · cites this paper as [18]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Assessment of sensitivity of acoustic reflex decay test in diagnosis of patulous eustachian tube
Attia, A. A. A., Abou-Setta, A. E. A., & Ashary, Y. M. (2024) · The Egyptian Journal of Otolaryngology · doi:10.1186/s43163-024-00579-4
Metadata
- Authors
- McGrath, A. P., & Michaelides, E. M.
- Venue
- Journal of the American Academy of Audiology
- Publisher
- American Academy of Audiology
- Published
- 2011-04-01
- Volume
- 22
- Issue
- 4
- Pages
- 201-207
- ISSN
- 1050-0545
- Cited by
- 18
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.