Microvolume Protein Concentration Determination Using the NanoDrop 2000c Spectrophotometer
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Traditional spectrophotometry requires placing samples into cuvettes or capillaries. This is often impractical due to the limited sample volumes often used for protein analysis. The Thermo Scientific NanoDrop 2000c Spectrophotometer solves this issue with an innovative sample retention system that holds microvolume samples between two measurement surfaces using the surface tension properties of liquids, enabling the quantification of samples in volumes as low as 0.5-2 microL. The elimination of cuvettes or capillaries allows real time changes in path length, which reduces the measurement time while greatly increasing the dynamic range of protein concentrations that can be measured. The need for dilutions is also eliminated, and preparations for sample quantification are relatively easy as the measurement surfaces can be simply wiped with laboratory wipe. This video article presents modifications to traditional protein concentration determination methods for quantification of microvolume amounts of protein using A280 absorbance readings or the BCA colorimetric assay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stoscheck, C. M. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)82008-p · Cited by 1,438
Cited by
An overview of technical considerations for Western blotting applications to physiological research
Bass, J. J., Wilkinson, D. J., Rankin, D., Phillips, B. E., Szewczyk, N. J., Smith, K., & Atherton, P. J. (2017) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.12702 · Cited by 404
Saadeldin, I. M., Kim, S. J., Choi, Y. B., & Lee, B. C. (2014) · Cellular Reprogramming · doi:10.1089/cell.2014.0003 · Cited by 171
Accurate and Rapid Protein Concentration Measurement of in‐Process, High Concentration Protein Pools
McKechnie, W. S., Tugcu, N., & Kandula, S. (2018) · Biotechnology Progress · doi:10.1002/btpr.2695 · Cited by 12
“High concentration protein samples often have absorbance values at 280 nm (A280) outside the linear dynamic range of most traditional spectrophotometers.(1) Traditional UV/vis spectrophotometers utilizing a 1-cm path length could not accurately measure protein concentrations of samples with absorbances >1.”
Al-Rahahleh, R. Q., Roos, W. P., Saville, K. M., Andrews, J. F., Wu, Z., Koczor, C. A., Prakash, A., & Sobol, R. W. (2025) · DNA Repair · doi:10.1016/j.dnarep.2025.103845 · Cited by 9
Ardila-Leal, L. D., Poutou-Piñales, R. A., Morales-Álvarez, E. D., Rivera-Hoyos, C. M., Pedroza-Rodríguez, A. M., Quevedo-Hidalgo, B. E., & Pérez-Flórez, A. (2021) · SN Applied Sciences · doi:10.1007/s42452-020-04093-z · Cited by 4
Metadata
- Authors
- Desjardins, P., Hansen, J. B., & Allen, M.
- Venue
- Journal of Visualized Experiments
- Publisher
- MyJove Corporation
- Published
- 2009-11-04
- Issue
- 33
- ISSN
- 1940-087X (ISSN-L)
- DOI
- 10.3791/1610
- OpenAlex
- W1978568546
- Cited by
- 130
- References
- 1
- FWCI
- 0.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.