Pseudomonas aeruginosa and Saccharomyces cerevisiae Biofilm in Flow Cells
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Many microbial cells have the ability to form sessile microbial communities defined as biofilms that have altered physiological and pathological properties compared to free living microorganisms. Biofilms in nature are often difficult to investigate and reside under poorly defined conditions(1). Using a transparent substratum it is possible to device a system where simple biofilms can be examined in a non-destructive way in real-time: here we demonstrate the assembly and operation of a flow cell model system, for in vitro 3D studies of microbial biofilms generating high reproducibility under well-defined conditions(2,3). The system consists of a flow cell that serves as growth chamber for the biofilm. The flow cell is supplied with nutrients and oxygen from a medium flask via a peristaltic pump and spent medium is collected in a waste container. This construction of the flow system allows a continuous supply of nutrients and administration of e.g. antibiotics with minimal disturbance of the cells grown in the flow chamber. Moreover, the flow conditions within the flow cell allow studies of biofilm exposed to shear stress. A bubble trapping device confines air bubbles from the tubing which otherwise could disrupt the biofilm structure in the flow cell. The flow cell system is compatible with Confocal Laser Scanning Microscopy (CLSM) and can thereby provide highly detailed 3D information about developing microbial biofilms. Cells in the biofilm can be labeled with fluorescent probes or proteins compatible with CLSM analysis. This enables online visualization and allows investigation of niches in the developing biofilm. Microbial interrelationship, investigation of antimicrobial agents or the expression of specific genes, are of the many experimental setups that can be investigated in the flow cell system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Barken, K. B., Pamp, S. J., Yang, L., Gjermansen, M., Bertrand, J. J., Klausen, M., Givskov, M., Whitchurch, C. B., Engel, J. N., & Tolker‐Nielsen, T. (2008) · Environmental Microbiology · doi:10.1111/j.1462-2920.2008.01658.x · Cited by 418
Cited by
Antimicrobial susceptibility testing in biofilm-growing bacteria
Macia, M. D., Rojo-Molinero, E., & Oliver, A. (2014) · Clinical Microbiology and Infection · doi:10.1111/1469-0691.12651 · Cited by 537
Inactivation of staphylococcal phenol soluble modulins by serum lipoprotein particles
Surewaard, B. G. J., Nijland, R., Spaan, A. N., Kruijtzer, J. A. W., de Haas, C. J. C., & van Strijp, J. A. G. (2012) · PLoS Pathogens · doi:10.1371/journal.ppat.1002606 · Cited by 117
Arenas, J., Nijland, R., Rodriguez, F. J., Bosma, T. N. P., & Tommassen, J. (2013) · Molecular Microbiology · doi:10.1111/mmi.12097 · Cited by 70
“The flow cell system was assembled and sterilized as described (Weiss Nielsen et al., 2011).”
Ali Mohammed, M. M., Nerland, A. H., Al-Haroni, M., & Bakken, V. (2013) · Journal of Oral Microbiology · doi:10.3402/jom.v5i0.20015 · Cited by 59
Metadata
- Authors
- Weiss Nielsen, M., Sternberg, C., Molin, S., & Regenberg, B.
- Venue
- Journal of Visualized Experiments
- Publisher
- MyJove Corporation
- Published
- 2011-01-15
- Issue
- 47
- ISSN
- 1940-087X (ISSN-L)
- DOI
- 10.3791/2383
- OpenAlex
- W2088505995
- Cited by
- 49
- References
- 1
- FWCI
- 1.53
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.