Behavioral and Locomotor Measurements Using an Open Field Activity Monitoring System for Skeletal Muscle Diseases
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The open field activity monitoring system comprehensively assesses locomotor and behavioral activity levels of mice. It is a useful tool for assessing locomotive impairment in animal models of neuromuscular disease and efficacy of therapeutic drugs that may improve locomotion and/or muscle function. The open field activity measurement provides a different measure than muscle strength, which is commonly assessed by grip strength measurements. It can also show how drugs may affect other body systems as well when used with additional outcome measures. In addition, measures such as total distance traveled mirror the 6 min walk test, a clinical trial outcome measure. However, open field activity monitoring is also associated with significant challenges: Open field activity measurements vary according to animal strain, age, sex, and circadian rhythm. In addition, room temperature, humidity, lighting, noise, and even odor can affect assessment outcomes. Overall, this manuscript provides a well-tested and standardized open field activity SOP for preclinical trials in animal models of neuromuscular diseases. We provide a discussion of important considerations, typical results, data analysis, and detail the strengths and weaknesses of open field testing. In addition, we provide recommendations for optimal study design when using open field activity in a preclinical trial.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Raise standards for preclinical cancer research
Begley, C. G., & Ellis, L. M. (2012) · Nature · doi:10.1038/483531a · Cited by 2,979
Can Animal Models of Disease Reliably Inform Human Studies?
van der Worp, H. B., Howells, D. W., Sena, E. S., Porritt, M. J., Rewell, S., O'Collins, V., & Macleod, M. R. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000245 · Cited by 1,354
A call for transparent reporting to optimize the predictive value of preclinical research
Landis, S. C., Amara, S. G., Asadullah, K., Austin, C. P., Blumenstein, R., Bradley, E. W., Crystal, R. G., Darnell, R. B., Ferrante, R. J., Fillit, H., et al. (2012) · Nature · doi:10.1038/nature11556 · Cited by 1,196
Measuring normal and pathological anxiety-like behaviour in mice: a review
Belzung, C., & Griebel, G. (2001) · Behavioural Brain Research · doi:10.1016/s0166-4328(01)00291-1 · Cited by 912
Cited by
A tissue-like neurotransmitter sensor for the brain and gut
Li, J., Liu, Y., Yuan, L., Zhang, B., Bishop, E. S., Wang, K., Tang, J., Zheng, Y.-Q., Xu, W., Niu, S., et al. (2022) · Nature · doi:10.1038/s41586-022-04615-2 · Cited by 443
Freitas, M. A., Vasconcelos, A., Gonçalves, E. C. D., Ferrarini, E. G., Vieira, G. B., Cicia, D., Cola, M., Capasso, R., & Dutra, R. C. (2021) · Biomolecules · doi:10.3390/biom11040592 · Cited by 79
“It is a commonly used test to assess mice’s locomotor and behavioral activity levels, allowing for evaluating drug-related effects on different aspects of animal behavior [82,83].”
BackgroundCorrigan, F., Arulsamy, A., Collins-Praino, L. E., Holmes, J. L., & Vink, R. (2017) · Brain, Behavior, and Immunity · doi:10.1016/j.bbi.2017.04.006 · Cited by 46
Maldonado‐Devincci, A. M., Makdisi, J. G., Hill, A. M., Waters, R. C., Hall, N. I., Shobande, M. J., & Kumari, A. (2022) · Journal of Neuroscience Research · doi:10.1002/jnr.24814 · Cited by 21
Abbas, W., & Masip Rodo, D. (2019) · Sensors · doi:10.3390/s19153274 · Cited by 21
Metadata
- Authors
- Tatem, K. S., Quinn, J. L., Phadke, A., Yu, Q., Gordish-Dressman, H., & Nagaraju, K.
- Venue
- Journal of Visualized Experiments
- Publisher
- MyJove Corporation
- Published
- 2014-09-29
- Issue
- 91
- Pages
- 51785-51785
- ISSN
- 1940-087X (ISSN-L)
- OpenAlex
- W2080713443
- Cited by
- 219
- References
- 4
- FWCI
- 3.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.