The DOI matches its Crossref record.
Recent Advances in High-Efficiency Perovskite for Medical Sensors
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The working principle of perovskite electrochemical sensors is based on redox reactions between elements of the perovskite materials, which have variable oxidation states, and target substances, resulting in a response current.
“The working principle of perovskite electrochemical sensors is based on the redox reactions between the elements of the perovskite materials, which have variable oxidation states, and the target substances, resulting in a response current that completes the sensing process (Figure 3A) [20].”
From Design Strategies and Emerging Applications of Perovskite-Based Sensors (2025) · cites this paper as [20]
Perovskite sensors can detect target substances at extremely low concentrations, which is important for applications requiring high accuracy.
“This capability facilitates the precise detection of target substances at extremely low concentrations, which is pivotal for applications requiring high accuracy [20,21].”
From Design Strategies and Emerging Applications of Perovskite-Based Sensors (2025) · cites this paper as [20]
Integrating perovskite sensors into microchips using micro-nano fabrication techniques allows for long-term, real-time, and non-invasive monitoring of physiological parameters like heart rate, blood pressure, and respiratory.
“Integrating the perovskite sensors into microchips using micronano fabrication techniques allows for long-term, real-time, and non-invasive monitoring of physiological parameters like heart rate, blood pressure, and respiratory [20].”
From Design Strategies and Emerging Applications of Perovskite-Based Sensors (2025) · cites this paper as [20]
Citations
Cites
Still being checked.
Cited by
Sorted by citations
Design Strategies and Emerging Applications of Perovskite-Based Sensors
Li, Y., Ding, Y., Sun, J., Tan, S., Li, Y., Wang, X., Cai, J., Bai, J., Lv, X., Guo, W., et al. (2025) · SmartMat · doi:10.1002/smm2.70022 · Cited by 41
Wang, F., Murugan, P., Dong, S., Zheng, X., Man, J., Liu, Z., Zhang, W., Zhu, T., & Wang, H. (2023) · Photonics · doi:10.3390/photonics10030312 · Cited by 6
EDITORIAL: Unfolding the Mysterious Scroll of Novel Photoelectric Perovskite Step by Step
Zhao, J., & Zhang, W. (2023) · Journal of Inorganic Materials · doi:10.15541/jim20232000 · Cited by 5
Self-citationWang, W., Li, Y., Zhang, J., Chen, M., Liu, J., Kang, J., & Zhao, J. (2025) · Advanced Electronic Materials · doi:10.1002/aelm.202400947 · Cited by 3
Self-citation
Metadata
- Authors
- Yang, S., Xu, Y., Hao, Z., Qin, S., Zhang, R., Han, Y., Du, L., Zhu, Z., Du, A., Chen, X., Wu, H., Qiao, B., Li, J., Wang, Y., Sun, B., Yan, R., & Zhao, J.
- Affiliations
- Xingtai People's Hospital (CN)
- ORCID
- Venue
- Acta Physico Chimica Sinica
- Publisher
- Elsevier BV
- Published
- 2022
- Volume
- 0
- Issue
- 0
- Pages
- 2211025
- ISSN
- 1000-6818 (ISSN-L)
- OpenAlex
- W4313306819
- Cited by
- 4
- References
- 0
- Citations by year
- 2025: 2 · 2023: 2
- FWCI
- 0.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Acta Physico-Chimica Sinica (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Perovskite Materials and Applications
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Keywords
- biomedical sensors, photoelectric conversion, electrocatalytic sensor, surface plasmon resonance, band gap tuning, element substitution, photoluminescence, drug detection, cancer biomarker detection, metabolite detection, neurotransmitter detection, ultrasensitive detection, biocompatibility, phase transitions, colorimetric sensing, gas sensing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review