CoChat

Effect of GLP-1 on D-glucose transport, lipolysis and lipogenesis in adipocytes of obese subjects

Open access
Sancho, Verónica, Trigo, María, Martín-Duce, Antonio, González, Nieves, Acitores, Alicia, Arnés, Luis, Valverde, Isabel, Malaisse, Willy, Villanueva-Peñacarrillo, María · 2006 · International Journal of Molecular Medicine
Cited by 53

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

GLP-1 has anorectic properties and regulates fuel homeostasis through both its insulinotropic and insulinotrophic actions and effects in extrapancreatic tissue. This study is aimed at characterizing the response to GLP-1 of adipocytes from obese patients, in terms of D-glucose transport and lipid metabolism, in comparison with data from normal subjects. Adipocytes were obtained by enzymatic digestion from the abdominal fat tissue of 25 morbidly obese patients and 8 normal subjects undergoing bariatric or inguinal hernia surgery, respectively. Basal GLUT4 expression, D-glucose transport, glycerol release and lipogenesis were measured in cells treated, when required, with 10(-12)-10(-9) M GLP-1, insulin, glucagon and the GLP-1 structurally related peptides, exendin-4 and exendin-9. In obese patients, versus normal subjects, a trend towards lower values was found in GLUT4 protein or mRNA, although the differences were not statistically significant; insulin-stimulated glucose uptake was higher and cells did not respond to GLP-1, while both exendins (10(-10) and 10(-9) M) exerted an inhibitory action; basal lipolysis was higher and so was the effect of GLP-1 and glucagon, whereas insulin abolished the lipolytic action of all peptides; both basal lipogenesis and the response to insulin were higher while GLP-1 and exendin-4 were ineffective. These results document the analogies and dissimilarities between the response to GLP-1, exendin-4 and exendin-9, as well as to insulin and glucagon, relative to glucose transport and lipid metabolism of fat tissue from obese patients versus normal subjects, the reduced lipogenic effect and enhanced lipolytic action of GLP-1 being, perhaps, adequate for its therapeutic use in obesity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3892/ijmm.17.6.1133

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 53

Metadata

Authors
Sancho, V., Trigo, M., Martín-Duce, A., González, N., Acitores, A., Arnés, L., Valverde, I., Malaisse, W., & Villanueva-Peñacarrillo, M.
Venue
International Journal of Molecular Medicine
Published
2006-06-01
Volume
17
Issue
6
Pages
1133-7
ISSN
  • 1107-3756 (ISSN-L)
  • 1791-244X
OpenAlex
W1985262015
Cited by
53
References
5
FWCI
1.01
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.