The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Arthrodesis by the Distraction-Compression Method Using a Stainless Steel Implant
Abstract
ABSTRACT: A new process for arthrodesis in humans is presented. The process has been used successfully in the cervical spine of horses and has potential for human use. The concept is encompassed in the process of an anterior cervical fusion and is an adaptation of that established practice but using an implant of stainless steel containing autogenous bone graft to encourage through-the-implant growth of bone. In the future, it may have use in the human spine and other joints.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Anterior Approach for Removal of Ruptured Cervical Disks
Cloward, R. B. (1958) · Journal of Neurosurgery · doi:10.3171/jns.1958.15.6.0602 · Cited by 1,778
Cited by
Kuslich, S. D., Ulstrom, C. L., Griffith, S. L., Ahern, J. W., & Dowdle, J. D. (1998) · Spine · doi:10.1097/00007632-199806010-00019 · Cited by 508
In vitro and in vivo degradation of bioabsorbable PLLA spinal fusion cages
van Dijk, M., Tunc, D. C., Smit, T. H., Higham, P., Burger, E. H., & Wuisman, P. I. J. M. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10466 · Cited by 78
Metadata
- Authors
- Bagby, G. W.
- Venue
- Orthopedics
- Publisher
- SLACK, Inc.
- Published
- 1988-06
- Volume
- 11
- Issue
- 6
- Pages
- 931-934
- ISSN
- 0147-7447 (ISSN-L)
- 1938-2367
- OpenAlex
- W2257646375
- Cited by
- 369
- References
- 1
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Arthrodesis by the Distraction-Compression Method Using a Stainless Steel Implant. https://app.cochat.ai/papers/10.3928/0147-7447-19880601-13
- The paper
- Bagby, G. W. (1988). Arthrodesis by the Distraction-Compression Method Using a Stainless Steel Implant. Orthopedics. https://doi.org/10.3928/0147-7447-19880601-13
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.