Videokeratographic Indices to Aid in Screening for Keratoconus
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
PURPOSE: To design a computer software program with quantitative indices to aid in videokeratographic screening for keratoconus. METHODS: A computer software program was designed to calculate three indices quantifying the keratoconus phenotype from videokeratographics generated by the Topographic Modeling System: Central K (central steepening); I-S values (reflecting inferior-superior dioptric asymmetry); and SRAX (relative skewing of the steepest radial axes above and below the horizontal meridian). One hundred ninety-five normal and 40 keratoconus patients who had not previously worn contact lenses were analyzed with the software. These 235 patients were then studied with combinations of indices to determine how best to distinguish keratoconus from normals by videokeratographic. RESULTS: Central K greater than 47.20 diopters (D) and I-S value greater than 1.20 D detected 39 of 40 (98%) keratoconus patients, with 10 of 195 (5%) normals identified as keratoconus. By adding the SRAX index of greater than 21° to these indices, 39 of 40 (98%) keratoconus patients were identified, but only 1 of 195 (0.5%) normals was identified as keratoconus. CONCLUSIONS: This new index, which quantifies irregular astigmatism in keratoconus, increases the specificity of previously reported quantitative descriptors of keratoconus without decreasing their sensitivity. True sensitivity and specificity of these indices for identifying keratoconus must be verified on a separate patient population. [J Refract Surg. 1995;11:371-379.]
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Automated keratoconus screening with corneal topography analysis.
Maeda, N., Klyce, S. D., Smolek, M. K., & Thompson, H. W. (1994) · PubMed · Cited by 503
Computer-Assisted Corneal Topography in Keratoconus
Rabinowitz, Y. S., & McDonnell, P. J. (1989) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19891101-10 · Cited by 395
Self-citationQuantitative Descriptors of Corneal Topography: A Clinical Study
Wilson, S. E. (1991) · Archives of Ophthalmology · doi:10.1001/archopht.1991.01080030051037 · Cited by 272
[Corneal topography of keratoconus].
Żarnowski, T., Haszcz, D., & Zagorski, Z. (1997) · PubMed · Cited by 171
Cited by
Rabinowitz, Y. S. (1998) · Survey of Ophthalmology · doi:10.1016/s0039-6257(97)00119-7 · Cited by 2,744
Self-citationRisk Assessment for Ectasia after Corneal Refractive Surgery
Randleman, J. B., Woodward, M., Lynn, M. J., & Stulting, R. D. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2007.03.073 · Cited by 739
Risk factors and prognosis for corneal ectasia after LASIK
Randleman, J. B., Russell, B., Ward, M. A., Thompson, K. P., & Stulting, R. D. (2003) · Ophthalmology · doi:10.1016/s0161-6420(02)01727-x · Cited by 690
Rabinowitz, Y. S., & Rasheed, K. (1999) · Journal of Cataract & Refractive Surgery · doi:10.1016/s0886-3350(99)00195-9 · Cited by 475
Self-citationde Sanctis, U., Loiacono, C., Richiardi, L., Turco, D., Mutani, B., & Grignolo, F. M. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2008.02.020 · Cited by 389
Metadata
- Authors
- Rabinowitz, Y. S.
- Venue
- Journal of Refractive Surgery
- Publisher
- SLACK, Inc.
- Published
- 1995-09
- Volume
- 11
- Issue
- 5
- Pages
- 371-406
- ISSN
- 1042-962X (ISSN-L)
- 1081-597X
- OpenAlex
- W92324959
- Cited by
- 309
- References
- 4
- FWCI
- 2.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.