The DOI matches its Crossref record.
Prospective Randomized Trial of an Anterior Surface Modified Prolate Intraocular Lens
Abstract
ABSTRACT PURPOSE: We compare the contrast sensitivity obtained with an anterior surface modified prolate intraocular lens with the contrast sensitivity obtained with a standard spherical intraocular lens. METHODS: Patients presenting for cataract surgery in one eye were randomized to receive either the Tecnis Z9000 intraocular lens (Pharmacia) or the AMO AR40e Opti-Edge intraocular lens (AMO). Sine wave grating contrast sensitivity testing under mesopic and photopic conditions served as the principal outcome measure. RESULTS: The Tecnis Z9000 intraocular lens provided statistically significantly better contrast sensitivity at 1.5 and 3 cycles per degreee under mesopic conditions and at 6, 12 and 18 cycles per degree under photopic conditions. CONCLUSION: The use of a modified prolate intraocular lens during cataract surgery has the potential to improve contrast sensitivity under both mesopic and photopic conditions. [J Refract Surg 2002;18:692-696]
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A New Intraocular Lens Design to Reduce Spherical Aberration of Pseudophakic Eyes
Holladay, J. T., Piers, P. A., Koranyi, G., van der Mooren, M., & Norrby, N. E. S. (2002) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20021101-04 · Cited by 560
Self-citationComparison of visual performance with an aspheric intraocular lens and a spherical intraocular lens
Thiagarajan, M., McClenaghan, R., & Anderson, D. F. (2011) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2011.05.046 · Cited by 19
Metadata
- Authors
- Packer, M., Fine, I. H., Hoffman, R. S., & Piers, P. A.
- Venue
- Journal of Refractive Surgery
- Publisher
- SLACK, Inc.
- Published
- 2002-11
- Volume
- 18
- Issue
- 6
- Pages
- 692-696
- ISSN
- 1042-962X (ISSN-L)
- 1081-597X
- OpenAlex
- W2329722056
- Cited by
- 172
- References
- 0
- FWCI
- 12.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prospective Randomized Trial of an Anterior Surface Modified Prolate Intraocular Lens. https://app.cochat.ai/papers/10.3928/1081-597x-20021101-05
- The paper
- Packer, M., Fine, I. H., Hoffman, R. S., & Piers, P. A. (2002). Prospective Randomized Trial of an Anterior Surface Modified Prolate Intraocular Lens. Journal of Refractive Surgery. https://doi.org/10.3928/1081-597x-20021101-05
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.