Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 560

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

A New Intraocular Lens Design to Reduce Spherical Aberration of Pseudophakic Eyes

Holladay, Jack T, Piers, Patricia A, Koranyi, Gabor, van der Mooren, Marrie, Norrby, N E Sverker·2002·Journal of Refractive Surgery

Abstract

ABSTRACT PURPOSE: The aim of this study was to design and evaluate in the laboratory a new intraocular lena (IOL) intended to provide superior octtlar optical quality by reducing spherical aberration. METHODS: Corneal topography measurements were performed on 71 cataract patients using an Orbscan I. The measured corneal surface shapes were used to determine the wavefront aberration of each cornea. A model cornea was then designed to reproduce the measured average spherical aberration. This model cornea was used to design IOLs having a fixed amount of negative spherical aberration that partially compensates for the average positive spherical aberration of the cornea. Theoretical and physical eye models were used to assess the expected improvement in optical quality of an eye implanted with this lens. RESULTS: Measurements of optical quality provided evidence that if this modified prolate IOL was centered within 0.4 mm and tilted less than 7 degrees, it would exceed the optical performance of a conventional spherical IOL. This improvement occurred without an apparent loss in depth of focus. CONCLUSION: A new IOL with a prolate anterior surface, designed to partially compensate for the average spherical aberration of the cornea, is intended to improve the ocular optical quality of Pseudophakie patients. [J Refract Surg 2002;18: 683-691]

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3928/1081-597x-20021101-04

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 560

Metadata

Authors
Holladay, J. T., Piers, P. A., Koranyi, G., van der Mooren, M., & Norrby, N. E. S.
Venue
Journal of Refractive Surgery
Publisher
SLACK, Inc.
Published
2002-11
Volume
18
Issue
6
Pages
683-691
ISSN
  • 1042-962X (ISSN-L)
  • 1081-597X
OpenAlex
W2161036079
Cited by
560
References
11
FWCI
13.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A New Intraocular Lens Design to Reduce Spherical Aberration of Pseudophakic Eyes. https://app.cochat.ai/papers/10.3928/1081-597x-20021101-04
The paper
Holladay, J. T., Piers, P. A., Koranyi, G., van der Mooren, M., & Norrby, N. E. S. (2002). A New Intraocular Lens Design to Reduce Spherical Aberration of Pseudophakic Eyes. Journal of Refractive Surgery. https://doi.org/10.3928/1081-597x-20021101-04

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.