Integration of Scheimpflug-Based Corneal Tomography and Biomechanical Assessments for Enhancing Ectasia Detection
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
PURPOSE: To present the Tomographic and Biomechanical Index (TBI), which combines Scheimpflugbased corneal tomography and biomechanics for enhancing ectasia detection. METHODS: Patients from different continents were retrospectively studied. The normal group included 1 eye randomly selected from 480 patients with normal corneas and the keratoconus group included 1 eye randomly selected from 204 patients with keratoconus. There were two groups: 72 ectatic eyes with no surgery from 94 patients with very asymmetric ectasia (VAE-E group) and the fellow eyes of these patients with normal topography (VAE-NT group). Pentacam HR and Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany) parameters were analyzed and combined using different artificial intelligence methods. The accuracies for detecting ectasia of the Belin/Ambrósio Deviation (BAD-D) and Corvis Biomechanical Index (CBI) were compared to the TBI, considering the areas under receiver operating characteristic curves (AUROCs). RESULTS: The random forest method with leave-one-out cross-validation (RF/LOOCV) provided the best artificial intelligence model. The AUROC for detecting ectasia (keratoconus, VAE-E, and VAE-NT groups) of the TBI was 0.996, which was statistically higher (DeLong et al., P < .001) than the BAD-D (0.956) and CBI (0.936). The TBI cut-off value of 0.79 provided 100% sensitivity for detecting clinical ectasia (keratoconus and VAE-E groups) with 100% specificity. The AUROCs for the TBI, BAD-D, and CBI were 0.985, 0.839, and 0.822 in the VAE-NT group (DeLong et al., P < .001). An optimized TBI cut-off value of 0.29 provided 90.4% sensitivity with 96% specificity in the VAE-NT group. CONCLUSIONS: The TBI generated by the RF/LOOCV provided greater accuracy for detecting ectasia than other techniques. The TBI was sensitive for detecting subclinical (fruste) ectasia among eyes with normal topography in very asymmetric patients. The TBI may also confirm unilateral ectasia, potentially characterizing the inherent ectasia susceptibility of the cornea, which should be the subject of future studies. [ J Refract Surg. 2017;33(7):434–443.]
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
Rabinowitz, Y. S. (1998) · Survey of Ophthalmology · doi:10.1016/s0039-6257(97)00119-7 · Cited by 2,744
Global Consensus on Keratoconus and Ectatic Diseases
Gomes, J. A. P., Tan, D., Rapuano, C. J., Belin, M. W., Ambrósio, R., Guell, J. L., Malecaze, F., Nishida, K., & Sangwan, V. S. (2015) · Cornea · doi:10.1097/ico.0000000000000408 · Cited by 1,132
Self-citationDetection of Keratoconus With a New Biomechanical Index
Vinciguerra, R., Ambrósio, R., Elsheikh, A., Roberts, C. J., Lopes, B., Morenghi, E., Azzolini, C., & Vinciguerra, P. (2016) · Journal of Refractive Surgery · doi:10.3928/1081597x-20160629-01 · Cited by 502
Self-citationRabinowitz, Y. S., & Rasheed, K. (1999) · Journal of Cataract & Refractive Surgery · doi:10.1016/s0886-3350(99)00195-9 · Cited by 475
Arbelaez, M. C., Versaci, F., Vestri, G., Barboni, P., & Savini, G. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2012.06.005 · Cited by 256
Detection of Subclinical Keratoconus Using an Automated Decision Tree Classification
Smadja, D., Touboul, D., Cohen, A., Doveh, E., Santhiago, M. R., Mello, G. R., Krueger, R. R., & Colin, J. (2013) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2013.03.034 · Cited by 241
Dynamic ultra high speed Scheimpflug imaging for assessing corneal biomechanical properties
Ambrósio Jr, R., Ramos, I., Luz, A., Faria, F. C., Steinmueller, A., Krug, M., Belin, M. W., & Roberts, C. J. (2013) · Revista Brasileira de Oftalmologia · doi:10.1590/s0034-72802013000200005 · Cited by 205
Self-citationCorneal Ectasia after Photorefractive Keratectomy for Low Myopia
Malecaze, F., Coullet, J., Calvas, P., Fournié, P., Arné, J.-L., & Brodaty, C. (2006) · Ophthalmology · doi:10.1016/j.ophtha.2005.11.023 · Cited by 108
Horizontal pachymetric profile for the detection of keratoconus
Lopes, B. T., Ramos, I. C. D. O., Salomão, M. Q., Canedo, A. L., & Ambrósio, R. (2015) · Revista Brasileira de Oftalmologia · doi:10.5935/0034-7280.20150080 · Cited by 29
Self-citation
Cited by
Eliasy, A., Chen, K.-J., Vinciguerra, R., Lopes, B. T., Abass, A., Vinciguerra, P., Ambrósio Jr., R., Roberts, C. J., & Elsheikh, A. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00105 · Cited by 221
Self-citationEnhanced Tomographic Assessment to Detect Corneal Ectasia Based on Artificial Intelligence
Lopes, B. T., Ramos, I. C., Salomão, M. Q., Guerra, F. P., Schallhorn, S. C., Schallhorn, J. M., Vinciguerra, R., Vinciguerra, P., Price, F. W., Price, M. O., et al. (2018) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2018.08.005 · Cited by 205
Self-citationRefractive surgery beyond 2020
Ang, M., Gatinel, D., Reinstein, D. Z., Mertens, E., Alió del Barrio, J. L., & Alió, J. L. (2021) · Eye · doi:10.1038/s41433-020-1096-5 · Cited by 193
“subclinical keratoconus among eyes clinically deemed to have ‘normal topography’ [11].”
BackgroundMethodPromising Artificial Intelligence-Machine Learning-Deep Learning Algorithms in Ophthalmology
(2019) · Asia-Pacific Journal of Ophthalmology · doi:10.22608/apo.2018479 · Cited by 182
Current state and future prospects of artificial intelligence in ophthalmology: a review
Hogarty, D. T., Mackey, D. A., & Hewitt, A. W. (2019) · Clinical & Experimental Ophthalmology · doi:10.1111/ceo.13381 · Cited by 176
“suggested using a Tomographic and biomechanical index (TBI) that combined Scheimpflugbased corneal tomography (Pentacam HR) and biomechanical analysis (Corvis ST examinations).(29) They retrospectively studied 850 eyes with keratoconus (one random eye from 480 normal patients, one random eye from 204 patients; 72 eyes…”
BackgroundMethod
Metadata
- Authors
- Ambrósio, R., Lopes, B. T., Faria-Correia, F., Salomão, M. Q., Bühren, J., Roberts, C. J., Elsheikh, A., Vinciguerra, R., & Vinciguerra, P.
- Venue
- Journal of Refractive Surgery
- Publisher
- SLACK, Inc.
- Published
- 2017-07
- Volume
- 33
- Issue
- 7
- Pages
- 434-443
- ISSN
- 1042-962X (ISSN-L)
- 1081-597X
- OpenAlex
- W2728958029
- Cited by
- 477
- References
- 11
- FWCI
- 21.77
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.