The DOI matches its Crossref record.
Swept-Source OCT Angiography of the Retinal Vasculature Using Intensity Differentiation-based Optical Microangiography Algorithms
Open accessAbstract
BACKGROUND AND OBJECTIVE: To demonstrate the feasibility of using a 1,050-nm swept-source optical coherence tomography (SS-OCT) system to achieve noninvasive retinal vasculature imaging in human eyes. MATERIALS AND METHODS: Volumetric data sets were acquired using a 1-µm SS-OCT prototype that operated at a 100-kHz A-line rate. A scanning protocol designed to allow for motion contrast processing, referred to as OCT angiography or optical microangiography (OMAG), was used to scan an approximately 3 × 3–mm area in the central macular region of the retina within approximately 4.5 seconds. An intensity differentiation-based OMAG algorithm was used to extract three-dimensional retinal functional microvasculature information. RESULTS: Intensity signal differentiation generated capillary-level resolution en face OMAG images of the retina. The parafoveal capillaries were clearly visible, thereby allowing visualization of the foveal avascular zone in healthy subjects. CONCLUSION: The capability of OMAG to produce retinal vascular images was demonstrated using the 1-µm SS-OCT prototype. This technique has potential clinical value for studying retinal vasculature abnormalities. [ Ophthalmic Surg Lasers Imaging Retina. 2014;45:382–389.]
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kashani, A. H., Chen, C.-L., Gahm, J. K., Zheng, F., Richter, G. M., Rosenfeld, P. J., Shi, Y., & Wang, R. K. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.07.002 · Cited by 1,006
Self-citationOptical Coherence Tomography Angiography in Diabetic Retinopathy: A Prospective Pilot Study
Ishibazawa, A., Nagaoka, T., Takahashi, A., Omae, T., Tani, T., Sogawa, K., Yokota, H., & Yoshida, A. (2015) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2015.04.021 · Cited by 617
Optical coherence tomography based angiography [Invited]
Chen, C.-L., & Wang, R. K. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.001056 · Cited by 415
Self-citationMethods and algorithms for optical coherence tomography-based angiography: a review and comparison
Zhang, A., Zhang, Q., Chen, C.-L., & Wang, R. K. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.10.100901 · Cited by 371
Self-citationRoisman, L., Zhang, Q., Wang, R. K., Gregori, G., Zhang, A., Chen, C.-L., Durbin, M. K., An, L., Stetson, P. F., Robbins, G., et al. (2016) · Ophthalmology · doi:10.1016/j.ophtha.2016.01.044 · Cited by 261
Self-citation
Metadata
- Authors
- Huang, Y., Zhang, Q., Thorell, M. R., An, L., Durbin, M. K., Laron, M., Sharma, U., Gregori, G., Rosenfeld, P. J., & Wang, R. K.
- Venue
- Ophthalmic Surgery, Lasers and Imaging Retina
- Publisher
- SLACK, Inc.
- Published
- 2014-09
- Volume
- 45
- Issue
- 5
- Pages
- 382-389
- ISSN
- 1542-8877 (ISSN-L)
- 2325-8160
- 2325-8179
- OpenAlex
- W2109192379
- Cited by
- 210
- References
- 0
- FWCI
- 14.90
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Swept-Source OCT Angiography of the Retinal Vasculature Using Intensity Differentiation-based Optical Microangiography Algorithms. https://app.cochat.ai/papers/10.3928/23258160-20140909-08
- The paper
- Huang, Y., Zhang, Q., Thorell, M. R., An, L., Durbin, M. K., Laron, M., Sharma, U., Gregori, G., Rosenfeld, P. J., & Wang, R. K. (2014). Swept-Source OCT Angiography of the Retinal Vasculature Using Intensity Differentiation-based Optical Microangiography Algorithms. Ophthalmic Surgery, Lasers and Imaging Retina. https://doi.org/10.3928/23258160-20140909-08
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.