The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Methods and algorithms for optical coherence tomography-based angiography: a review and comparison
Open accessAbstract
Optical coherence tomography (OCT)-based angiography is increasingly becoming a clinically useful and important imaging technique due to its ability to provide volumetric microvascular networks innervating tissue beds in vivo without a need for exogenous contrast agent. Numerous OCT angiography algorithms have recently been proposed for the purpose of contrasting microvascular networks. A general literature review is provided on the recent progress of OCT angiography methods and algorithms. The basic physics and mathematics behind each method together with its contrast mechanism are described. Potential directions for future technical development of OCT based angiography is then briefly discussed. Finally, by the use of clinical data captured from normal and pathological subjects, the imaging performance of vascular networks delivered by the most recently reported algorithms is evaluated and compared, including optical microangiography, speckle variance,phase variance, split-spectrum amplitude decorrelation angiography, and correlation mapping. It is found that the method that utilizes complex OCT signal to contrast retinal blood flow delivers the best performance among all the algorithms in terms of image contrast and vessel connectivity. The purpose of this review is to help readers understand and select appropriate OCT angiography algorithm for use in specific applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Global prevalence and major risk factors of diabetic retinopathy
Yau, J. W. Y., Rogers, S. L., Kawasaki, R., Lamoureux, E. L., Kowalski, J. W., Bek, T., Chen, S.-J., Dekker, J. M., Fletcher, A., Grauslund, J., et al. (2012) · Diabetes Care · doi:10.2337/dc11-1909 · Cited by 4,985
Digital Spectral Analysis with Applications
Marple, S. L., & Carey, W. M. (1989) · The Journal of the Acoustical Society of America · doi:10.1121/1.398548 · Cited by 1,984
Split-spectrum amplitude-decorrelation angiography with optical coherence tomography
Jia, Y., Tan, O., Tokayer, J., Potsaid, B., Wang, Y., Liu, J. J., Kraus, M. F., Subhash, H., Fujimoto, J. G., Hornegger, J., et al. (2012) · Optics Express · doi:10.1364/oe.20.004710 · Cited by 1,841
Digital spectral analysis : with applications
Marple, S. L. (1987) · International Linear Collider · Cited by 1,732
The impact of ocular blood flow in glaucoma
Flammer, J., Orgül, S., Costa, V. P., Orzalesi, N., Krieglstein, G. K., Serra, L. M., Renard, J.-P., & Stefánsson, E. (2002) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(02)00008-3 · Cited by 1,709
Measurement of intraocular distances by backscattering spectral interferometry
Fercher, A. F., Hitzenberger, C. K., Kamp, G., & El-Zaiat, S. Y. (1995) · Optics Communications · doi:10.1016/0030-4018(95)00119-s · Cited by 1,212
Laser speckle contrast imaging in biomedical optics
Boas, D. A., & Dunn, A. K. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3285504 · Cited by 1,122
Speckle in Optical Coherence Tomography
Schmitt, J. M., Xiang, S. H., & Yung, K. M. (1999) · Journal of Biomedical Optics · doi:10.1117/1.429925 · Cited by 837
Vakoc, B. J., Lanning, R. M., Tyrrell, J. A., Padera, T. P., Bartlett, L. A., Stylianopoulos, T., Munn, L. L., Tearney, G. J., Fukumura, D., Jain, R. K., et al. (2009) · Nature Medicine · doi:10.1038/nm.1971 · Cited by 719
Cited by
Kashani, A. H., Chen, C.-L., Gahm, J. K., Zheng, F., Richter, G. M., Rosenfeld, P. J., Shi, Y., & Wang, R. K. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.07.002 · Cited by 1,006
Self-citationAge-related macular degeneration
Guymer, R. H., & Campbell, T. G. (2023) · The Lancet · doi:10.1016/s0140-6736(22)02609-5 · Cited by 502
Optical coherence tomography based angiography [Invited]
Chen, C.-L., & Wang, R. K. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.001056 · Cited by 415
Self-citation
Metadata
- Authors
- Zhang, A., Zhang, Q., Chen, C.-L., & Wang, R. K.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2015-10-16
- Volume
- 20
- Issue
- 10
- Pages
- 100901
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W1932853004
- Cited by
- 371
- References
- 40
- FWCI
- 19.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Methods and algorithms for optical coherence tomography-based angiography: a review and comparison. https://app.cochat.ai/papers/10.1117/1.jbo.20.10.100901
- The paper
- Zhang, A., Zhang, Q., Chen, C.-L., & Wang, R. K. (2015). Methods and algorithms for optical coherence tomography-based angiography: a review and comparison. Journal of Biomedical Optics. https://doi.org/10.1117/1.jbo.20.10.100901
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.