Use of the sleep laboratory in suspected sleep apnea syndrome: Is one night enough?
The DOI matches its Crossref record.
Abstract
BACKGROUND: Sleep-disordered breathing appears to vary widely from night to night in the general population. OBJECTIVE: To determine the difference in accuracy of diagnosing sleep apnea when there are one vs two sleep recordings in a clinical population. METHODS: Fifty patients clinically suspected of having obstructive sleep apnea underwent polysomnography for two nights. RESULTS: The number of episodes of apnea or hypopnea per hour (the apnea-hypopnea index, AHI) on each night was highly correlated (r = .86), and there were no significant differences between the two nights in duration of episodes, mean minimal arterial oxygen desaturation, or absolute minimum desaturation. On the first night, 46 patients had an AHI of 5 or more; on the second night 49 did. Similarly, 42 patients had an AHI of 10 or more on the first night; on the second night 46 did. All patients with an AHI of 5 or more on the first night also had an AHI of 5 or more the second night, and only one patient who had an AHI of 10 or more on the first night did not on the second night. In contrast, some nonrespiratory variables improved on the second night. CONCLUSIONS: One night of testing should generally suffice. A second recording might be expected to be positive in half of the small group of patients clinically suspected of having sleep apnea who have a negative first study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Oral Appliances for the Treatment of Snoring and Obstructive Sleep Apnea: A Review
Schmidt-Nowara, W., Lowe, A., Wiegand, L., Cartwright, R., Perez-Guerra, F., & Menn, S. (1995) · Sleep · doi:10.1093/sleep/18.6.501 · Cited by 543
The first-night effect may last more than one night
Le Bon, O., Staner, L., Hoffmann, G., Dramaix, M., San Sebastian, I., Murphy, J. R., Kentos, M., Pelc, I., & Linkowski, P. (2001) · Journal of Psychiatric Research · doi:10.1016/s0022-3956(01)00019-x · Cited by 227
Iber, C., Redline, S., Gilpin, A. M. K., Quan, S. F., Zhang, L., Gottlieb, D. J., Rapoport, D., Resnick, H. E., Sanders, M., & Smith, P. (2004) · Sleep · doi:10.1093/sleep/27.3.536 · Cited by 195
Goodwin, J. L., Enright, P. L., Kaemingk, K. L., Rosen, G. M., Morgan, W. J., Fregosi, R. F., & Quan, S. F. (2001) · Sleep · doi:10.1093/sleep/24.8.937 · Cited by 175
Night-to-night variability of polysomnography in children with suspected obstructive sleep apnea
Katz, E. S., Greene, M. G., Carson, K. A., Galster, P., Loughlin, G. M., Carroll, J., & Marcus, C. L. (2002) · The Journal of Pediatrics · doi:10.1067/mpd.2002.123290 · Cited by 158
A Comprehensive Evaluation of a Two-Channel Portable Monitor to “Rule in” Obstructive Sleep Apnea
Ward, K. L., McArdle, N., James, A., Bremner, A. P., Simpson, L., Cooper, M. N., Palmer, L. J., Fedson, A. C., Mukherjee, S., & Hillman, D. R. (2015) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.4600 · Cited by 39
“…of order of comparison 18, 19, 27 , For laboratory-based PSG it is generally recognized that a first-night effect results in poor sleep efficiency and underesti - mation of OSA, 34–36 due to the large number of sensors applied, limiting sleep to the supine posture in an unfamiliar environment.”
InfluentialRanderath, W., Bauer, M., Blau, A., Fietze, I., Galetke, W., Hein, H., Maurer, J. T., Orth, M., Rasche, K., Ruhle, K.-H., et al. (2006) · Somnologie · doi:10.1111/j.1439-054x.2006.00082.x · Cited by 19
Metadata
- Authors
- Mendelson, W. B.
- Venue
- Cleveland Clinic Journal of Medicine
- Publisher
- Cleveland Clinic Journal of Medicine
- Published
- 1994-07-01
- Volume
- 61
- Issue
- 4
- Pages
- 299-303
- ISSN
- 0891-1150 (ISSN-L)
- 1939-2869
- OpenAlex
- W2319448399
- Cited by
- 52
- References
- 0
- FWCI
- 0.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.