Heart rate variability with deep breathing as a clinical test of cardiovagal function
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Research into heart rate variability (HRV) and respiration over the past 150 years has led to the insight that HRV with deep breathing (HRVdb) is a highly sensitive measure of cardiovagal or parasympathetic cardiac function. This sensitivity makes HRVdb an important part of the battery of cardiovascular autonomic function tests used in clinical autonomic laboratories. HRVdb is a reliable and sensitive clinical test for early detection of cardiovagal dysfunction in a wide range of autonomic disorders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Akselrod, S., Gordon, D., Ubel, F. A., Shannon, D. C., Berger, A. C., & Cohen, R. J. (1981) · Science · doi:10.1126/science.6166045 · Cited by 5,079
Respiratory sinus arrhythmia: noninvasive measure of parasympathetic cardiac control
Katona, P. G., & Jih, F. (1975) · Journal of Applied Physiology · doi:10.1152/jappl.1975.39.5.801 · Cited by 792
Idiopathic autonomic neuropathy: Clinical, neurophysiologie, and follow‐up studies on 27 patients
Suarez, G. A., Fealey, R. D., Camilleri, M., & Low, P. A. (1994) · Neurology · doi:10.1212/wnl.44.9.1675 · Cited by 171
Cited by
Advances in Photopletysmography Signal Analysis for Biomedical Applications
Moraes, J. L., Rocha, M. X., Vasconcelos, G. G., Vasconcelos Filho, J. E., De Albuquerque, V. H. C., & Alexandria, A. R. (2018) · Sensors · doi:10.3390/s18061894 · Cited by 292
“The frequency domain analysis is delimited in three distinct frequency bands, called spectral components, independently of the calculation of the spectral density (Fourier Transform Techniques or auto regressive model) [85,86].”
BackgroundHuman cerebral circuitry related to cardiac control: a neuroimaging meta-analysis
Ruiz Vargas, E., Sörös, P., Shoemaker, J. K., & Hachinski, V. (2016) · Annals of Neurology · doi:10.1002/ana.24642 · Cited by 94
Effects of slow and regular breathing exercise on cardiopulmonary coupling and blood pressure
Zhang, Z., Wang, B., Wu, H., Chai, X., Wang, W., & Peng, C.-K. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1517-6 · Cited by 32
Building resilience with the Stress Resilience Training System: Design validation and applications
de Visser, E. J., Dorfman, A., Chartrand, D., Lamon, J., Freedy, E., & Weltman, G. (2016) · Work · doi:10.3233/wor-162295 · Cited by 21
Metadata
- Authors
- Shields, R. W.
- Venue
- Cleveland Clinic Journal of Medicine
- Publisher
- Cleveland Clinic Journal of Medicine
- Published
- 2009-02
- Volume
- 76
- Issue
- 4 suppl 2
- Pages
- S37-S40
- ISSN
- 0891-1150 (ISSN-L)
- 1939-2869
- OpenAlex
- W2133643089
- Cited by
- 129
- References
- 3
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.