The DOI matches its OpenAlex record; 1 of the 1 references it cites were found in a registry or an index.
The potential of terahertz imaging for cancer diagnosis: A review of investigations to date.
Open accessAbstract
The terahertz region lies between the microwave and infrared regions of the electromagnetic spectrum such that it is strongly attenuated by water and very sensitive to water content. Terahertz radiation has very low photon energy and thus it does not pose any ionization hazard for biological tissues. Because of these characteristic properties, there has been an increasing interest in terahertz imaging and spectroscopy for biological applications within the last few years and more and more terahertz spectra are being reported, including spectroscopic studies of cancer. The presence of cancer often causes increased blood supply to affected tissues and a local increase in tissue water content may be observed: this acts as a natural contrast mechanism for terahertz imaging of cancer. Furthermore the structural changes that occur in affected tissues have also been shown to contribute to terahertz image contrast. This paper introduces terahertz technology and provides a short review of recent advances in terahertz imaging and spectroscopy techniques. In particular investigations relating to the potential of terahertz imaging and spectroscopy for cancer diagnosis will be highlighted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Terahertz pulsed imaging and spectroscopy for biomedical and pharmaceutical applications
Wallace, V. P., Taday, P. F., Fitzgerald, A. J., Woodward, R. M., Cluff, J., Pye, R. J., & Arnone, D. D. (2004) · Faraday Discussions · doi:10.1039/b309357n · Cited by 160
Cited by
Tutorial: An introduction to terahertz time domain spectroscopy (THz-TDS)
Neu, J., & Schmuttenmaer, C. A. (2018) · Journal of Applied Physics · doi:10.1063/1.5047659 · Cited by 675
Noninvasive, near-field terahertz imaging of hidden objects using a single-pixel detector
Stantchev, R. I., Sun, B., Hornett, S. M., Hobson, P. A., Gibson, G. M., Padgett, M. J., & Hendry, E. (2016) · Science Advances · doi:10.1126/sciadv.1600190 · Cited by 499
Zhang, J., Mu, N., Liu, L., Xie, J., Feng, H., Yao, J., Chen, T., & Zhu, W. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113241 · Cited by 325
Islam, M. S., Sultana, J., Ahmed, K., Islam, M. R., Dinovitser, A., Ng, B. W.-H., & Abbott, D. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2775642 · Cited by 305
Yu, L., Hao, L., Meiqiong, T., Jiaoqi, H., Wei, L., Jinying, D., Xueping, C., Weiling, F., & Yang, Z. (2019) · RSC Advances · doi:10.1039/c8ra10605c · Cited by 305
Metadata
- Authors
- Yu, C., Fan, S., Sun, Y., & Pickwell‐MacPherson, E.
- Venue
- PubMed
- Publisher
- National Institutes of Health
- Published
- 2012-03-01
- Volume
- 2
- Issue
- 1
- Pages
- 33-45
- OpenAlex
- W2164464237
- Cited by
- 289
- References
- 1
- FWCI
- 9.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The potential of terahertz imaging for cancer diagnosis: A review of investigations to date. https://app.cochat.ai/papers/10.3978/j.issn.2223-4292.2012.01.04
- The paper
- Yu, C., Fan, S., Sun, Y., & Pickwell‐MacPherson, E. (2012). The potential of terahertz imaging for cancer diagnosis: A review of investigations to date. PubMed. https://doi.org/10.3978/j.issn.2223-4292.2012.01.04
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.