The DOI matches its Crossref record.
Electrochemical surface modification of titanium in dentistry
Abstract
Titanium and its alloys have good biocompatibility with body cells and tissues and are widely used for implant applications. However, clinical procedures place more stringent and tough requirements on the titanium surface necessitating artificial surface treatments. Among the many methods of titanium surface modification, electrochemical techniques are simple and cheap. Anodic oxidation is the anodic electrochemical technique while electrophoretic and cathodic depositions are the cathodic electrochemical techniques. By anodic oxidation it is possible to obtain desired roughness, porosity and chemical composition of the oxide. Anodic oxidation at high voltages can improve the crystallinity of the oxide. The chief advantage of this technique is doping of the coating of the bath constituents and incorporation of these elements improves the properties of the oxide. Electrophoretic deposition uses hydroxyapatite (HA) powders dispersed in a suitable solvent at a particular pH. Under these operating conditions these particles acquire positive charge and coatings are obtained on the cathodic titanium by applying an external electric field. These coatings require a post-sintering treatment to improve the coating properties. Cathodic deposition is another type of electrochemical method where HA is formed in situ from an electrolyte containing calcium and phosphate ions. It is also possible to alter structure and/or chemistry of the obtained deposit. Nano-grained HA has higher surface energy and greater biological activity and therefore emphasis is being laid to produce these coatings by cathodic deposition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Engineering biocompatible implant surfaces
Bauer, S., Schmuki, P., von der Mark, K., & Park, J. (2013) · Progress in Materials Science · doi:10.1016/j.pmatsci.2012.09.001 · Cited by 780
Titanium nanostructures for biomedical applications
Kulkarni, M., Mazare, A., Gongadze, E., Perutkova, Š., Kralj-Iglič, V, Milošev, I., Schmuki, P., Iglič, A., & Mozetič, M. (2015) · Nanotechnology · doi:10.1088/0957-4484/26/6/062002 · Cited by 506
Chai, Y. C., Carlier, A., Bolander, J., Roberts, S. J., Geris, L., Schrooten, J., Van Oosterwyck, H., & Luyten, F. P. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.07.002 · Cited by 305
Nanoscale surface modifications of medically relevant metals: state-of-the art and perspectives
Variola, F., Brunski, J. B., Orsini, G., Tambasco de Oliveira, P., Wazen, R., & Nanci, A. (2011) · Nanoscale · doi:10.1039/c0nr00485e · Cited by 260
Multiple aspects of the interaction of biomacromolecules with inorganic surfaces
Fenoglio, I., Fubini, B., Ghibaudi, E. M., & Turci, F. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.08.001 · Cited by 176
Metadata
- Authors
- KIM, K.-H., & RAMASWAMY, N.
- Venue
- Dental Materials Journal
- Published
- 2009
- Volume
- 28
- Issue
- 1
- Pages
- 20-36
- ISSN
- 0287-4547 (ISSN-L)
- 1881-1361
- OpenAlex
- W2092838269
- Cited by
- 171
- References
- 0
- FWCI
- 25.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochemical surface modification of titanium in dentistry. https://app.cochat.ai/papers/10.4012/dmj.28.20
- The paper
- KIM, K.-H., & RAMASWAMY, N. (2009). Electrochemical surface modification of titanium in dentistry. Dental Materials Journal. https://doi.org/10.4012/dmj.28.20
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.