The DOI matches its Crossref record; 114 of the 114 references it cites were found in a registry or an index.
Titanium nanostructures for biomedical applications
Open accessAbstract
Titanium and titanium alloys exhibit a unique combination of strength and biocompatibility, which enables their use in medical applications and accounts for their extensive use as implant materials in the last 50 years. Currently, a large amount of research is being carried out in order to determine the optimal surface topography for use in bioapplications, and thus the emphasis is on nanotechnology for biomedical applications. It was recently shown that titanium implants with rough surface topography and free energy increase osteoblast adhesion, maturation and subsequent bone formation. Furthermore, the adhesion of different cell lines to the surface of titanium implants is influenced by the surface characteristics of titanium; namely topography, charge distribution and chemistry. The present review article focuses on the specific nanotopography of titanium, i.e. titanium dioxide (TiO2) nanotubes, using a simple electrochemical anodisation method of the metallic substrate and other processes such as the hydrothermal or sol-gel template. One key advantage of using TiO2 nanotubes in cell interactions is based on the fact that TiO2 nanotube morphology is correlated with cell adhesion, spreading, growth and differentiation of mesenchymal stem cells, which were shown to be maximally induced on smaller diameter nanotubes (15 nm), but hindered on larger diameter (100 nm) tubes, leading to cell death and apoptosis. Research has supported the significance of nanotopography (TiO2 nanotube diameter) in cell adhesion and cell growth, and suggests that the mechanics of focal adhesion formation are similar among different cell types. As such, the present review will focus on perhaps the most spectacular and surprising one-dimensional structures and their unique biomedical applications for increased osseointegration, protein interaction and antibacterial properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Methods: Fundamentals and Applications
Bard, A. J., & Faulkner, L. R. (1980) · Cited by 22,435
Electrochemical Methods: Fundamentals and Applications
de Rooij, D. M. R. (2003) · Anti-Corrosion Methods and Materials · doi:10.1108/acmm.2003.12850eae.001 · Cited by 13,009
Ti based biomaterials, the ultimate choice for orthopaedic implants – A review
Geetha, M., Singh, A. K., Asokamani, R., & Gogia, A. K. (2009) · Progress in Materials Science · doi:10.1016/j.pmatsci.2008.06.004 · Cited by 5,416
Surface modification of titanium, titanium alloys, and related materials for biomedical applications
LIU, X., CHU, P., & DING, C. (2004) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2004.11.001 · Cited by 3,487
TiO2 Nanotubes: Synthesis and Applications
Roy, P., Berger, S., & Schmuki, P. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201001374 · Cited by 3,134
Self-citationOn the mechanisms of biocompatibility
Williams, D. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.023 · Cited by 2,772
Exploring and Engineering the Cell Surface Interface
Stevens, M. M., & George, J. H. (2005) · Science · doi:10.1126/science.1106587 · Cited by 2,607
RGD modified polymers: biomaterials for stimulated cell adhesion and beyond
Hersel, U., Dahmen, C., & Kessler, H. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00343-0 · Cited by 2,582
Osteoblast adhesion on biomaterials
Anselme, K. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00242-2 · Cited by 2,500
Formation of Titanium Oxide Nanotube
Kasuga, T., Hiramatsu, M., Hoson, A., Sekino, T., & Niihara, K. (1998) · Langmuir · doi:10.1021/la9713816 · Cited by 2,475
Cited by
León, A., Reuquen, P., Garín, C., Segura, R., Vargas, P., Zapata, P., & Orihuela, P. (2017) · Applied Sciences · doi:10.3390/app7010049 · Cited by 675
About metastable cellular structure in additively manufactured austenitic stainless steels
Kong, D., Dong, C., Wei, S., Ni, X., Zhang, L., Li, R., Wang, L., Man, C., & Li, X. (2021) · Additive Manufacturing · doi:10.1016/j.addma.2020.101804 · Cited by 528
Multifunctional antimicrobial materials: From rational design to biomedical applications
Duan, S., Wu, R., Xiong, Y.-H., Ren, H.-M., Lei, C., Zhao, Y.-Q., Zhang, X.-Y., & Xu, F.-J. (2022) · Progress in Materials Science · doi:10.1016/j.pmatsci.2021.100887 · Cited by 257
Fit and forget: The future of dental implant therapy via nanotechnology
Gulati, K., Chopra, D., Kocak-Oztug, N. A., & Verron, E. (2023) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2023.114900 · Cited by 89
Smart hydrogel-functionalized textile system with moisture management property for skin application
Wang, X., Hu, H., Yang, Z., He, L., Kong, Y., Fei, B., & Xin, J. H. (2014) · Smart Materials and Structures · doi:10.1088/0964-1726/23/12/125027 · Cited by 58
Metadata
- Authors
- Kulkarni, M., Mazare, A., Gongadze, E., Perutkova, Š., Kralj-Iglič, V, Milošev, I., Schmuki, P., Iglič, A., & Mozetič, M.
- Venue
- Nanotechnology
- Publisher
- IOP Publishing
- Published
- 2015-01-22
- Volume
- 26
- Issue
- 6
- Pages
- 062002
- ISSN
- 0957-4484 (ISSN-L)
- 1361-6528
- OpenAlex
- W2146487730
- Cited by
- 506
- References
- 114
- FWCI
- 28.47
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Titanium nanostructures for biomedical applications. https://app.cochat.ai/papers/10.1088/0957-4484/26/6/062002
- The paper
- Kulkarni, M., Mazare, A., Gongadze, E., Perutkova, Š., Kralj-Iglič, V, Milošev, I., Schmuki, P., Iglič, A., & Mozetič, M. (2015). Titanium nanostructures for biomedical applications. Nanotechnology. https://doi.org/10.1088/0957-4484/26/6/062002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.