Preparation and Characterization of Hydroxyapatite/Zinc Composites with Alginate for Bone Scaffold Application
Open accessThe DOI matches its Crossref record; 12 of the 13 references it cites were found in a registry or an index, and 1 are not checked yet; none of the 39 sources its claims cite is checked for support yet.
Abstract
Alginate addition did not change the HAp-Zn structure and phase; the uppermost ultimate compressive strength and modulus of elasticity were 2.05 ± 0.06 MPa and 0.037 ± 0.001 GPa at 6% alginate.
Checked 2026-11-23 · 1 reference not checked yet
Overview
CoChat Summary
TL;DR
HAp-Zn/SA composite scaffolds with 0–6% sodium alginate were prepared and characterized. Alginate did not alter the HAp-Zn phase but reduced crystallinity and crystallite size, produced interconnected pores, and increased compressive strength, peaking at 2.05 ± 0.06 MPa for 6% SA.
Key findings
- XRD showed hexagonal HAp and parascholzite (CaZn₂(PO₄)₂H₂O), indicating Zn incorporation; alginate addition did not change the HAp-Zn phase/structure. Crystallinity decreased from 77.63% to 74.14%, 72.92%, and 70.21%, and crystallite size decreased from 11.77 nm to 9.56 nm, 8.54 nm, and 7.2 nm with increasing alginate.
- FTIR confirmed phosphate groups and alginate COO⁻ peaks at 1434 cm⁻¹ and 1640–1641 cm⁻¹; OH stretching appeared at 3465–3434 cm⁻¹, and a C-Cl group at 633–631 cm⁻¹ was attributed to PBS. Peak intensities increased with alginate addition.
- SEM showed 0% SA samples as powders with low interconnection, while alginate-containing samples had pores of 50–200 µm with good interconnectivity, suitable for cell attachment and growth (100–300 µm).
- Compressive strength increased with alginate concentration; HAp-Zn/SA6% reached 2.05 ± 0.06 MPa compressive strength and 0.037 ± 0.001 GPa modulus of elasticity. This was still below an earlier study’s 3.3–9.01 MPa, possibly due to decreased crystallinity, but all samples were considered potentially applicable for pelvis head spongy parts requiring 1–15 MPa.
Methods
- Zn-doped HAp powder was synthesized by sol-gel with microwave support: CaO dissolved in 2 M HNO₃, reacted with 0.18 M (NH₄)₂HPO₄, ZnCl₂ (15% w/v) added at pH 10, microwave radiation for 10 min, aging 24 h, washing to pH 7, drying, and sintering at 600°C for 2 h.
- HAp-Zn/SA scaffolds were prepared with PBS:sample ratio 1:1, sodium alginate at 0%, 2%, 4%, and 6% in 0.65 M PBS, mixed with HAp-Zn powder, crosslinked with 1.08 M CaCl₂, stirred at 50°C, aged 24 h, poured into cylindrical molds, and freeze-dried at −30°C for 24 h.
- Characterization included XRD (Bruker D8 Advance, 2θ = 10°–90°, Cu-Kα), crystallinity and Scherrer crystallite-size analysis, FTIR (4000–400 cm⁻¹, 4 cm⁻¹ resolution), SEM (Hitachi S3000N, 10 kV, gold-coated), and compressive testing (Universal Tensile Machine, 13 mm diameter × 25 mm height, ASTM E9-89a, 5 N load, 1.0 mm/min, three measurements per group).
Limitations
- Stated: The paper notes limited prior studies on HAp-Zn/SA and that the maximum compressive strength remained below an earlier study’s 3.3–9.01 MPa, possibly due to decreased crystallinity.
- Stated: No dedicated limitations section is included in the paper.
- Evident from the text: Only physicochemical and mechanical characterization is reported; no in vitro/in vivo biocompatibility, degradation, or antibacterial testing appears in the provided text.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 27 Not checked · 24 Own results and interpretations
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“It was obtained that crystallinity of the HAp-Zn/SA decreased moderately accounting for 77.63%, 74.14%, 72.92%, and 70.21% with the addition of alginate concentration.”
§ Preparation and Characterization of Hydroxyapatite/Zinc Composites with Alginate for Bone Scaffold Application > 4 Mechanical Engineering
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“In general, the results of the FTIR spectrum (Fig. 2) revealed the HAp-Zn was considered with a bending symmetry phosphate (PO₄³⁻) group mainly between 561-567 cm⁻¹ of wavenumber.”
§ Preparation and Characterization of Hydroxyapatite/Zinc Composites with Alginate for Bone Scaffold Application > Advances in Science and Technology Vol. 125
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Besides, the peak for the bending and stretching asymmetric phosphate (PO₄³⁻) groups were also spotted at 605 cm⁻¹ and 1037 cm⁻¹.”
§ Preparation and Characterization of Hydroxyapatite/Zinc Composites with Alginate for Bone Scaffold Application > Advances in Science and Technology Vol. 125
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“It indicated that alginate addition did not affect the structure and the phase of HAp-Zn.”
§ Preparation and Characterization of Hydroxyapatite/Zinc Composites with Alginate for Bone Scaffold Application > 4 Mechanical Engineering
hedged- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
In the paper
“Nevertheless, this maximum value was still below compared to the earlier study reaching 3.3 -9.01 MPa [16].”
§ Preparation and Characterization of Hydroxyapatite/Zinc Composites with Alginate for Bone Scaffold Application > Mechanical Properties Analysis.
What the sources say
- Not checked yetcites [16] Sintesis dan Karakterisasi Biokomposit Hidroksiapatit-Alginat-Zinc Sebagai Bone Graft untuk Penanganan Bone Defect. J N Setiadiputri, J. Chem. Inf. Model. 539J. N. Setiadiputri, Sintesis dan Karakterisasi Biokomposit Hidroksiapatit-Alginat-Zinc Sebagai Bone Graft untuk Penanganan Bone Defect, J. Chem. Inf. Model., vol. 53, no. 9 (2018) 1-102.
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
29 more claims
Create a free account to see all 51 claims and to verify the 35 references still open.
- It may state two separate claims as one. 10
- Probably not a substantial claim. 8
Citations
Cites
Hydroxyapatite and Hydroxyapatite-Based Ceramics
Orlovskii, V. P., Komlev, V. S., & Barinov, S. M. (2002) · Inorganic Materials · doi:10.1023/a:1020585800572 · Cited by 312 · cited 1×
“However, all samples were potentially applied in the pelvis head with a requirement of 1-15 MPa for the spongy parts [20].”
BackgroundOfudje, E. A., Adeogun, A. I., Idowu, M. A., & Kareem, S. O. (2019) · Heliyon · doi:10.1016/j.heliyon.2019.e01716 · Cited by 213
Thadavirul, N., Pavasant, P., & Supaphol, P. (2014) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35010 · Cited by 187
Rajkumar, M., Meenakshisundaram, N., & Rajendran, V. (2011) · Materials Characterization · doi:10.1016/j.matchar.2011.02.008 · Cited by 161 · cited 2×
“Alginate was chosen because it is biocompatible, biodegradable, non-toxic, non-immunogenic, and has a relatively low cost for biomedical applications [6, 7, 8].”
BackgroundAlborzi, S., Lim, L., & Kakuda, Y. (2012) · Journal of Microencapsulation · doi:10.3109/02652048.2012.696153 · Cited by 93
Continuous microwave flow synthesis of mesoporous hydroxyapatite
Akram, M., Alshemary, A. Z., Goh, Y.-F., Ibrahim, W. A. W., Lintang, H. O., & Hussain, R. (2015) · Materials Science and Engineering C · doi:10.1016/j.msec.2015.06.040 · Cited by 44
Safari-Gezaz, M., Aref, S. M., & Khatamian, M. (2019) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2019.01.005 · Cited by 36
Indrani, D. J., Budiyanto, E., & Hayun, H. (2018) · International Journal of Applied Pharmaceutics · doi:10.22159/ijap.2017.v9s2.24 · Cited by 14
SINTESIS DAN UJI POROSITAS SCAFFOLD HIDROKSIAPATIT/ALGINAT
Milla, L. E., Indrani, D. J., & Irawan, B. (2018) · ODONTO : Dental Journal · doi:10.30659/odj.5.1.49-53 · Cited by 6 · cited 1×
“stated that a lower concentration of alginate generated lower viscosity because of less PBS consumption, which sublimated easily in the freeze-drying method [18].”
MethodUsman, U., Manalu, D. F., & Apriyanti, Y. (2019) · FROPIL (Forum Profesional Teknik Sipil) · doi:10.33019/fropil.v6i1.1269 · Cited by 4
Research works printed but not linked: 4
- A A Maharani, A Husni, N Ekantari, Karakteristik Natrium Alginat Rumput Laut Cokelat Sargassum Fluitans dengan Metode Ekstraksi yang Berbeda, Jphpi. 20A. A. Maharani, A. Husni, and N. Ekantari, Karakteristik Natrium Alginat Rumput Laut Cokelat Sargassum Fluitans dengan Metode Ekstraksi yang Berbeda, Jphpi, vol. 20, no. 3, (2017) 478-487.
- Perancah Berpori Hidroksiapatit dan β-Tricalcium Phosphate dari Limbah Cangkang Telur Ayam dengan Porogen Alginat Fitri Afriani. F Afriani, F. Afriani, Perancah Berpori Hidroksiapatit dan β-Tricalcium Phosphate dari Limbah Cangkang Telur Ayam dengan Porogen Alginat Fitri Afriani, (2015). · DOI
- Sintesis dan Karakterisasi Biokomposit Hidroksiapatit-Alginat-Zinc Sebagai Bone Graft untuk Penanganan Bone Defect. J N Setiadiputri, J. Chem. Inf. Model. 539J. N. Setiadiputri, Sintesis dan Karakterisasi Biokomposit Hidroksiapatit-Alginat-Zinc Sebagai Bone Graft untuk Penanganan Bone Defect, J. Chem. Inf. Model., vol. 53, no. 9 (2018) 1-102.
- Sintesis Scaffold Alginat-Kitosan-Karbonat Apatit Sebagai Bone Graft Menggunakan Metode. M R Aufan, A H Daulay, D Indriani, A Nuruddin, J. Biofisika. 81M. R. Aufan, A. H. Daulay, D. Indriani, and A. Nuruddin, Sintesis Scaffold Alginat-Kitosan- Karbonat Apatit Sebagai Bone Graft Menggunakan Metode, J. Biofisika, vol. 8, no. 1, (2012) 16-24.
Metadata
- Authors
- Ramadhani, J., Tajalla, G. U. N., Yusariarta, A. W., Rachmantyo, R., & Wibowo, A.
- Affiliations
- Institut Teknologi Kalimantan (ID)
- Institut Teknologi Kalimantan
- Bandung Institute of Technology (ID)
- Corresponding author
- Ramadhani, Jane
- Venue
- Advances in Science and Technology
- Publisher
- Trans Tech Publications Ltd
- Published
- 2023-03-01
- Volume
- 125
- Pages
- 3-9
- ISSN
- 1661-819X (ISSN-L)
- 1662-0356
- OpenAlex
- W4322741193
- Cited by
- 0
- References
- 12
- FWCI
- 0.00
- Type
- conference paper
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- www.scientific.net/PolicyAndEthics/PublishingPolicies (vor)
- www.scientific.net/license/TDM_Licenser.pdf (tdm)
- Locations
- Advances in science and technology (publishedVersion, cc-by)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Mechanical Engineering › Surface Treatment and Coatings
- Keywords
- alginate, bone scaffolds, porous scaffolds, low-temperature processing, alginate concentration, crystallinity, compressive strength, elastic modulus, intermolecular interactions, bone regeneration
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.