CoChat

A comparison of five methods of temperature measurement in febrile intensive care patients

Schmitz, T, Bair, N, Falk, M, Levine, C · 1995 · American Journal of Critical Care
Cited by 117

The DOI matches its Crossref record.

Abstract

BACKGROUND: A clinically useful temperature measurement method should correlate well with the body's core temperature. Although previous investigators have studied temperature readings from different sites in hypothermic and normothermic patients, none have compared methods specifically in febrile patients. OBJECTIVE: To compare temperature measurement methods in febrile intensive care patients. METHODS: Temperature readings were obtained in rapid sequence from an electronic thermometer for oral and axillary temperature, rectal probe, infrared ear thermometer on "core" setting, and pulmonary artery catheter, approximately every hour during the day and every 4 hours at night. The sample consisted of 13 patients with pulmonary artery catheters and with temperatures of at least 37.8 degrees C. RESULTS: Rectal temperature correlated most closely with pulmonary artery temperature. Rectal temperature showed closest agreement with pulmonary artery temperature, followed by oral, ear-based, and axillary temperatures. Rectal and ear-based temperatures were most sensitive in detecting temperatures greater than 38.3 degrees C. Likelihood ratios for detecting hyperthermia were 5.32 for oral, 2.46 for rectal, and 1.97 for ear-based temperature. Rectal and ear-based temperatures had the lowest negative likelihood ratios, indicating the least chance of a false negative reading. Axillary temperature had a negative likelihood ratio of 0.86. CONCLUSIONS: Rectal temperature measurement correlates most closely with core temperature. If the rectal site is contraindicated, oral or ear-based temperatures are acceptable. Axillary temperature does not correlate well with pulmonary artery temperature. These results underscore the importance of consistency in method when establishing temperature trends, and of awareness of method when interpreting clinical data.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4037/ajcc1995.4.4.286

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 117

Metadata

Authors
Schmitz, T., Bair, N., Falk, M., & Levine, C.
Venue
American Journal of Critical Care
Published
1995-07-01
Volume
4
Issue
4
Pages
286-292
ISSN
  • 1062-3264 (ISSN-L)
  • 1937-710X
OpenAlex
W2340502210
Cited by
117
References
0
FWCI
2.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A comparison of five methods of temperature measurement in febrile intensive care patients. https://app.cochat.ai/papers/10.4037/ajcc1995.4.4.286
The paper
Schmitz, T., Bair, N., Falk, M., & Levine, C. (1995). A comparison of five methods of temperature measurement in febrile intensive care patients. American Journal of Critical Care. https://doi.org/10.4037/ajcc1995.4.4.286

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.