CoChat

Electrocardiography Pitfalls and Artifacts: The 10 Commandments

Baranchuk, Adrian, Shaw, Catherine, Alanazi, Haitham, Campbell, Debra, Bally, Kathy, Redfearn, Damian P., Simpson, Christopher S., Abdollah, Hoshiar · 2009 · Critical Care Nurse
Cited by 60

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

What potential pitfalls can adversely affect the interpretation of 12-lead ECGs?Many potential pitfalls can adversely affect the interpretation of 12-lead ambulatory and telemetry electrocardiograms (ECGs). Artifacts, for example, are a common finding in patients who require ECG monitoring. Artifacts are defined as ECG abnormalities that may be due to sources other than the electrical activity of the heart. Failure to correctly distinguish between an arrhythmia and artifact can result in misdiagnosis and unnecessary therapeutic interventions.1The most common causes of artifacts originate from internal (physiological) and external (non-physiological) sources (Table 1). Artifacts created from these sources can simulate arrhythmias such as atrial flutter and ventricular tachycardia.2Electrode misplacement is another common artifact. Such misplacement may lead to changes in ECG morphology that could potentially be interpreted as ischemic in origin.3 Electrode misplacements can also mimic serious arrhythmias and lead to misdirected therapeutic decisions.4 Electrode misplacement is a relatively frequent finding in ECGs done in outpatient clinics (0.4%) and is even more common in intensive care units (4%).4 The correct position for precordial ECG electrodes is illustrated in Figure 1.Several telltale clues can help clinicians identify potential signs of electrode misplacements and artifacts. In this article, we introduce an algorithm that we developed to assist nurses and physicians in rapidly recognizing those clues and review 10 of the most common ECG pitfalls and artifacts.The indicators of electrode misplacements or artifacts that clinicians need to look for can be easily remembered by using the mnemonic REVERSE (Table 2). With this mnemonic in mind, careful and systematic examination of ECGs will help rule out problems with the recording.We describe the 10 most common ECG pitfalls and artifacts seen in our practice, presented in the form of commandments. All the ECG examples provided for this review were run at 25 mm/s, 10 mm/mV, and 100 Hz.Reversing the electrodes is one of the most common errors made when placing the ECG on a patient. Such reversal produces leads I and AVL with reverse polarity of all normal deflections (negative P wave, QRS complex, and T wave). In addition, polarity is reversed in lead AVR (positive P and QRS; Figure 2). The differential diagnosis is dextrocardia (the heart is positioned on the right side). In dextrocardia, however, the progression of the R wave in pre-cordial leads is reversed, whereas with electrode reversal, the progression is normal.5The possibility of tremor or other interference inducing an artifact that mimics ventricular tachycardia should be considered when the ECG does not match the patient’s clinical findings. A normal heart rate obtained by pulse or auscultation in an asymptomatic patient at the same time the ECG shows apparent ventricular tachycardia confirms the diagnosis. Reduction of the tremor by holding the limb or placing the electrodes on the torso will reduce interference.2,6,7 “Tracking” the R-R intervals is helpful if they can be identified before the pseudo– ventricular tachycardia. Look for R-R intervals that continue into the wide complex rhythm to see the presence of normal ventricular depolarizations throughout the pseudo–ventricular tachycardia. With careful measuring to see where normal beats should be, they will often “jump out” at the observer and become obvious, whereas at first glance they may be completely obscured. Pseudo–ventricular tachycardia has 3 characteristic signs8 (Figure 3):Amplitude of the P wave in lead I greater than in lead II and/or P-wave terminal positive component in lead III (Abdollah sign) will confirm reversal of the left arm and left leg leads.9 Confirmation with a second ECG is usually required (Figure 4).The most common reversal of the precordial leads is an exchange of V1 and V6. The way to recognize this problem is by assessing the R-wave progression in the precordial leads. Normally, the R wave will increase its amplitude from V1 to V6 and the S wave will decrease its amplitude. In the reversal situation, a tall R wave can be seen in V1 and a deep S wave in V610–13 Potential diagnostic misinterpretations include right bundle branch block, old posterior myocardial infarction, right ventricular hypertrophy, and left-sided accessory pathways (Figure 5).Tremor-induced artifact may mimic supraventricular arrhythmias (atrial flutter/atrial fibrillation) or if the artifact has sufficient amplitude, it can also mimic ventricular tachycardia and ventricular fibrillation. The correct diagnosis can be made on the basis of simple observations such as the presence of the pseudoarrhythmia when the patient moves (tremor). Careful analysis may reveal discrete components of the QRS complexes (matching the previous R-R intervals if present) through the pseudoarrhythmia (“notches sign”).8,14–16 Misinterpretation of tremor-induce

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4037/ccn2009607

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 60

Metadata

Authors
Baranchuk, A., Shaw, C., Alanazi, H., Campbell, D., Bally, K., Redfearn, D. P., Simpson, C. S., & Abdollah, H.
Venue
Critical Care Nurse
Published
2009-02-01
Volume
29
Issue
1
Pages
67-73
ISSN
  • 0279-5442 (ISSN-L)
  • 1940-8250
OpenAlex
W2102600146
Cited by
60
References
2
FWCI
2.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrocardiography Pitfalls and Artifacts: The 10 Commandments. https://app.cochat.ai/papers/10.4037/ccn2009607
The paper
Baranchuk, A., Shaw, C., Alanazi, H., Campbell, D., Bally, K., Redfearn, D. P., Simpson, C. S., & Abdollah, H. (2009). Electrocardiography Pitfalls and Artifacts: The 10 Commandments. Critical Care Nurse. https://doi.org/10.4037/ccn2009607

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.