Cited by 181Advanced Sensor and Energy Harvesting MaterialsNeuroscience and Neural EngineeringNanomaterials and Printing Technologies

Self-adhesive epidermal carbon nanotube electronics for tether-free long-term continuous recording of biosignals

Open access
Lee, Seung Min, Byeon, Hang Jin, Lee, Joong Hoon, Baek, Dong Hyun, Lee, Kwang Ho, Hong, Joung Sook, Lee, Sang-Hoon·2014·Scientific Reports

Abstract

The long-term, continuous, inconspicuous, and noiseless monitoring of bioelectrical signals is critical to the early diagnosis of disease and monitoring health and wellbeing. However, it is a major challenge to record the bioelectrical signals of patients going about their daily lives because of the difficulties of integrating skin-like conducting materials, the measuring system, and medical technologies in a single platform. In this study, we developed a thin epidermis-like electronics that is capable of repeated self-adhesion onto skin, integration with commercial electronic components through soldering, and conformal contact without serious motion artifacts. Using well-mixed carbon nanotubes and adhesive polydimethylsiloxane, we fabricated an epidermal carbon nanotube electronics which maintains excellent conformal contact even within wrinkles in skin, and can be used to record electrocardiogram signals robustly. The electrode is biocompatible and can even be operated in water, which means patients can live normal lives despite wearing a complicated recording system.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/srep06074

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The CNT/aPDMS electrode patch was ultrathin (120 μm), extremely compliant (modulus of 27.5 kPa) and waterproof.

    “the resulting electrode patch (Figure 3e) was ultrathin (120 µm), extremely compliant (modulus of 27.5 kPa) and waterproof.”

    From Nanomaterial-Enabled Wearable Sensors for Healthcare (2018) · cites this paper as [95]

  • Nanomaterial-enabled dry electrodes have been demonstrated for wearable and long-term ECG sensing without irritating the skin.

    “Nanomaterialenabled dry electrodes have been demonstrated for wearable and long-term ECG sensing without irritating the skin.[92,95,100]”

    From Nanomaterial-Enabled Wearable Sensors for Healthcare (2018) · cites this paper as [95]

  • Only preliminary experiments were performed on biocompatibility of nanomaterials for wearable applications.

    “For example, only preliminary experiments were performed on biocompatibility of nanomaterials for wearable applications.[94,95,205]”

    From Nanomaterial-Enabled Wearable Sensors for Healthcare (2018) · cites this paper as [95]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Lee, S. M., Byeon, H. J., Lee, J. H., Baek, D. H., Lee, K. H., Hong, J. S., & Lee, S.-H.
Affiliations
  • Korea University (KR)
  • Kangwon National University (KR)
  • Soongsil University (KR)
Corresponding author
Lee, Sang-Hoon
Venue
Scientific Reports
Published
2014-08-15
Volume
4
Issue
1
Pages
6074-6074
ISSN
2045-2322 (ISSN-L)
OpenAlex
W1970992788
Cited by
181
References
34
Citations by year
2026: 6 · 2025: 13 · 2024: 16 · 2023: 18 · 2022: 16 · 2021: 19 · 2020: 19 · 2019: 28 · 2018: 14 · 2017: 20 · 2016: 8 · 2015: 4
FWCI
5.53
Type
journal article
Language
en
Open access
Locations
  • Scientific Reports (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
Keywords
epidermal electronics, carbon nanotubes, self-adhesive electrodes, ECG monitoring, polydimethylsiloxane, motion artifacts, biocompatible electrodes, wearable health monitoring
MeSH terms
Adhesives, Biocompatible Materials, Electrocardiography, Equipment Design, Humans, Materials Testing, Microelectrodes, Biosensing Techniques, Monitoring, Ambulatory, Nanotubes, Carbon

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review