Translational Applications of Flow Cytometry in Clinical Practice
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Flow cytometry has evolved over the past 30 y from a niche laboratory technique to a routine tool used by clinical pathologists and immunologists for diagnosis and monitoring of patients with cancer and immune deficiencies. Identification of novel patterns of expressed Ags has led to the recognition of cancers with unique pathophysiologies and treatment strategies. FACS had permitted the isolation of tumor-free populations of hematopoietic stem cells for cancer patients undergoing stem cell transplantation. Adaptation of flow cytometry to the analysis of multiplex arrays of fluorescent beads that selectively capture proteins and specific DNA sequences has produced highly sensitive and rapid methods for high through-put analysis of cytokines, Abs, and HLA genotypes. Automated data analysis has contributed to the development of a “cytomics” field that integrates cellular physiology, genomics, and proteomics. In this article, we review the impact of the flow cytometer in these areas of medical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bomberger, C., Singh-Jairam, M., Rodey, G., Guerriero, A., Yeager, A. M., Fleming, W. H., Holland, H. K., & Waller, E. K. (1998) · Blood · doi:10.1182/blood.v91.7.2588 · Cited by 183
Self-citation
Cited by
Highly multiplexed simultaneous detection of RNAs and proteins in single cells
Frei, A. P., Bava, F.-A., Zunder, E. R., Hsieh, E. W. Y., Chen, S.-Y., Nolan, G. P., & Gherardini, P. F. (2016) · Nature Methods · doi:10.1038/nmeth.3742 · Cited by 330
flowAI: automatic and interactive anomaly discerning tools for flow cytometry data
Monaco, G., Chen, H., Poidinger, M., Chen, J., de Magalhães, J. P., & Larbi, A. (2016) · Bioinformatics · doi:10.1093/bioinformatics/btw191 · Cited by 280
Biomarker detection for disease diagnosis using cost-effective microfluidic platforms
Sanjay, S. T., Fu, G., Dou, M., Xu, F., Liu, R., Qi, H., & Li, X. (2015) · The Analyst · doi:10.1039/c5an00780a · Cited by 267
Poudineh, M., Aldridge, P. M., Ahmed, S., Green, B. J., Kermanshah, L., Nguyen, V., Tu, C., Mohamadi, R. M., Nam, R. K., Hansen, A., et al. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2016.239 · Cited by 248
Kverneland, A. H., Streitz, M., Geissler, E., Hutchinson, J., Vogt, K., Boës, D., Niemann, N., Pedersen, A. E., Schlickeiser, S., & Sawitzki, B. (2016) · Cytometry Part A · doi:10.1002/cyto.a.22855 · Cited by 99
Metadata
- Authors
- Jaye, D. L., Bray, R. A., Gebel, H. M., Harris, W. A. C., & Waller, E. K.
- Venue
- The Journal of Immunology
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-05
- Volume
- 188
- Issue
- 10
- Pages
- 4715-4719
- ISSN
- 0022-1767 (ISSN-L)
- 1550-6606
- OpenAlex
- W2153226221
- Cited by
- 109
- References
- 1
- FWCI
- 5.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.