The DOI matches its Crossref record.
The immunogenicity of soluble haptenated polymers is determined by molecular mass and hapten valence.
Abstract
T cell-independent Ag are believed to stimulate antibody formation in the relative absence of Ag processing and T cell help. Previous studies on the type 2 T cell independent (TI-2) Ag DNP-polyacrylamide, have shown that when one systematically varies the molecular mass and hapten valence, the immunogenic potential of this type of molecule depends on definable molecular characteristics. It was found that to be immunogenic, these molecules had to exceed a threshold molecular mass of 100,000 Da and a threshold hapten valence of 20. The present study was undertaken to determine whether such findings could be generalized to other molecules belonging to the TI-2 class of Ag. The molecular characteristics of five chemically different fluoresceinated (FL)-polymers were systematically varied, and their ability to stimulate an IgM antihapten immune response was measured. The polymers used as carriers were carefully size-fractionated and consisted of one natural polymer (dextran), one modified natural polymer (carboxymethyl cellulose), and three synthetic polymers (Ficoll, polyvinyl alcohol, and polyacrylamide). The carriers varied in physical structure from the highly cross-linked Ficoll, to the somewhat branched dextran, to the linear polyacrylamide, carboxymethyl cellulose, and polyvinyl alcohol. Polymers were haptenated with FL and size-fractionated so as to yield a panel of molecules with varying molecular mass, hapten valence, and hapten density. Anti-FL IgM response to these haptenated polymers was measured in vivo after i.p. injection of the FL-polymer in saline, and measured in vitro after culture with unfractionated spleen cells from naive mice. In agreement with the previous studies on DNP-polyacrylamide, it was found that to be immunogenic, each of the FL-polymers had to exceed a comparable threshold value of molecular mass and of hapten valence. Optimal immunogenicity occurred when the FL-polymers had values of mass and hapten density lying within a predictable range. Immunogenicity decreased when these optimal parameters were substantially increased or decreased. We conclude that the immunogenicity of soluble haptenated polymers depends on predictable physical molecular characteristics, and is relatively independent of the chemical composition and conformation of the carrier polymer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Effects of protein aggregates: An immunologic perspective
Rosenberg, A. S. (2006) · The AAPS Journal · doi:10.1208/aapsj080359 · Cited by 1,355
Synthetic Multivalent Ligands as Probes of Signal Transduction
Kiessling, L. L., Gestwicki, J. E., & Strong, L. E. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200502794 · Cited by 864
The Influence of Antigen Organization on B Cell Responsiveness
Bachmann, M. F., Rohrer, U. H., Kündig, T. M., Bürki, K., Hengartner, H., & Zinkernagel, R. M. (1993) · Science · doi:10.1126/science.8248784 · Cited by 717
Paus, D., Phan, T. G., Chan, T. D., Gardam, S., Basten, A., & Brink, R. (2006) · The Journal of Experimental Medicine · doi:10.1084/jem.20060087 · Cited by 567
Davis, B. G. (2002) · Chemical Reviews · doi:10.1021/cr0004310 · Cited by 521
Metadata
- Authors
- Dintzis, R. Z., Okajima, M., Middleton, M. H., Greene, G., & Dintzis, H. M.
- Venue
- The Journal of Immunology
- Publisher
- Oxford University Press (OUP)
- Published
- 1989-08
- Volume
- 143
- Issue
- 4
- Pages
- 1239-1244
- ISSN
- 0022-1767 (ISSN-L)
- 1550-6606
- OpenAlex
- W2170864258
- Cited by
- 159
- References
- 0
- FWCI
- 1.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The immunogenicity of soluble haptenated polymers is determined by molecular mass and hapten valence. https://app.cochat.ai/papers/10.4049/jimmunol.143.4.1239
- The paper
- Dintzis, R. Z., Okajima, M., Middleton, M. H., Greene, G., & Dintzis, H. M. (1989). The immunogenicity of soluble haptenated polymers is determined by molecular mass and hapten valence. The Journal of Immunology. https://doi.org/10.4049/jimmunol.143.4.1239
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.