Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Application of 3D Electromagnetic Articulography in Dentistry: Mastication and Deglutition Analysis. Protocol Report

Open access
Fuentes, Ramón, Dias, Fernando, Álvarez, Giannina, Lezcano, María Florencia, Farfán, Constanza, Astete, Nicolás, Arias, Alain · 2018 · International journal of odontostomatology

Abstract

The Stomatognathic System (SS) is an integrated and coordinated morphofunctional unit, consisting of skeletal, muscular, angiological, nervous, glandular and dental structures that work in harmony to perform different functions such as chewing, swallowing, speaking, breathing, tasting and esthetics.The study of SS physiology is crucial to achieving a correct maintenance of its normal function or restoration.Thus, we developed a protocol to record mandibular movement, chewing and swallowing (saliva and water) by using the 3D-electromagnetic articulograph AG501 at the Oral Physiology Laboratory of the Research Centre for Dental Sciences (CICO).This tool has been used for decades in speech and phonetic research and it is able to record, present and evaluate articulated structure movement data in real time.The articulograph provides an ordered data matrix (values for the x, y, z axes, among others) for the recorded movement, which is stored in binary files that can be processed by different software.One of these is MATLAB ® , allowing us to perform a quick, clear and understandable analysis.The existence of a standardized methodology for recording allows an accurate description of the stages to perform different types of measurements according to the researcher's objective.This has opened the way for a new type of oral physiology analysis based on study reproducibility, which is considered one of the bases of scientific methodology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4067/s0718-381x2018000100105

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 A) AG501 3D electromagnetic articulograph (Carstens Medizinelektronik, Bovenden, Germany) from the Oral Physiology Laboratory of the Research Center for Dental Sciences (CICO), Universidad de La Frontera. The articulograph has 9 transmitter coils and 16 receiver coils or sensors that can be placed on the participant or subject of study. (Arrow) Field of spherical measurement of 300 mm diameter of the articulograph. The participantÕs head with the placed sensors must be within this field of measurement to ensure the accuracy of the recordings. B) Matrix scheme of ordered data provided by the articulograph. The output format of this data matrix is a binary file (.pos), which can be processed by different software. C) Standardization scheme of recorded movement and establishment of a reference system. Absolute movement in which the whole system moves and the absolute position (movement) of each sensor is recorded. B) Relative movement, in which a reference system of three sensors (violet, green and light green points) is established that is used to present the movement of the rest of active sensors (black and blue lines). Although the entire system (sensor set) moves, the distance between the reference sensors and the active sensor does not change, so the movement is not relative, but absolute.
Fig. 1 A) AG501 3D electromagnetic articulograph (Carstens Medizinelektronik, Bovenden, Germany) from the Oral Physiology Laboratory of the Research Center for Dental Sciences (CICO), Universidad de La Frontera. The articulograph has 9 transmitter coils and 16 receiver coils or sensors that can be placed on the participant or subject of study. (Arrow) Field of spherical measurement of 300 mm diameter of the articulograph. The participantÕs head with the placed sensors must be within this field of measurement to ensure the accuracy of the recordings. B) Matrix scheme of ordered data provided by the articulograph. The output format of this data matrix is a binary file (.pos), which can be processed by different software. C) Standardization scheme of recorded movement and establishment of a reference system. Absolute movement in which the whole system moves and the absolute position (movement) of each sensor is recorded. B) Relative movement, in which a reference system of three sensors (violet, green and light green points) is established that is used to present the movement of the rest of active sensors (black and blue lines). Although the entire system (sensor set) moves, the distance between the reference sensors and the active sensor does not change, so the movement is not relative, but absolute.CC-BY-NC · From the PDF
Fig. 2 Visualization in VisArtico software of the sensor movements recorded by the AG501 3D electromagnetic articulograph. In this case, mandibular opening movement (arrow). With this software, it is possible to obtain the positional data of any point in the movement trajectory (boxes).
Fig. 2 Visualization in VisArtico software of the sensor movements recorded by the AG501 3D electromagnetic articulograph. In this case, mandibular opening movement (arrow). With this software, it is possible to obtain the positional data of any point in the movement trajectory (boxes).CC-BY-NC · From the PDF
Fig. 3 A) For the protocol for recording jaw and chewing movement. Distribution of the articulograph sensors placed at specific points on the patient's head: skin point of the right (1) and left (2) mastoid (behind ears), glabella (3), mid-incisive mandibular midline (4) and skin point of the thyroid cartilage (5). B) For the recording protocol of tongue movement when swallowing saliva and water: distribution of the articulograph sensors placed at specific points on the patient's head. Skin point of the right (1) and left (2) mastoid, glabella (3), mandibular mid-incisive midpoint (4), skin point of the thyroid cartilage (5), anterior (6), middle (7) and posterior (8) portion of the tongue. An extra sensor (9) was used to define the sagittal profile of the hard and soft palate.
Fig. 3 A) For the protocol for recording jaw and chewing movement. Distribution of the articulograph sensors placed at specific points on the patient's head: skin point of the right (1) and left (2) mastoid (behind ears), glabella (3), mid-incisive mandibular midline (4) and skin point of the thyroid cartilage (5). B) For the recording protocol of tongue movement when swallowing saliva and water: distribution of the articulograph sensors placed at specific points on the patient's head. Skin point of the right (1) and left (2) mastoid, glabella (3), mandibular mid-incisive midpoint (4), skin point of the thyroid cartilage (5), anterior (6), middle (7) and posterior (8) portion of the tongue. An extra sensor (9) was used to define the sagittal profile of the hard and soft palate.CC-BY-NC · From the PDF
Fig. 4 Graphs generated in MATLAB¨ (in 3D) of the movement recorded with the AG501 3D electromagnetic articulograph. A) Opening and laterality movement without any right or left contact.Ê B) Envelope of contacting and bordering jaw movements in the frontal plane. C) Envelope of contacting and bordering jaw movements in the sagittal plane. D) Chewing cycles.
Fig. 4 Graphs generated in MATLAB¨ (in 3D) of the movement recorded with the AG501 3D electromagnetic articulograph. A) Opening and laterality movement without any right or left contact.Ê B) Envelope of contacting and bordering jaw movements in the frontal plane. C) Envelope of contacting and bordering jaw movements in the sagittal plane. D) Chewing cycles.CC-BY-NC · From the PDF
Fig. 5 Graphs generated in MATLAB¨ of the movement recorded with the AG501 3D electromagnetic articulograph. Time graphs of sensor movement on the tongue (anterior, middle and posterior; red lines), jaw (blue line) and skin point of the thyroid cartilage (green line) in the three anatomical axes: x-craniosacral (A) ylateral-lateral (B) and z-dorsoventral (C). Special types of Fig.s composed by a sequence of articulated segment graphs (D) were generated, representing a specific time at the beginning (E), middle (F) and final of swallowing (G). These articulated segments are formed by the union of three points (corresponding to the three sensors placed on the tongue: anterior, middle and posterior) through straight lines.
Fig. 5 Graphs generated in MATLAB¨ of the movement recorded with the AG501 3D electromagnetic articulograph. Time graphs of sensor movement on the tongue (anterior, middle and posterior; red lines), jaw (blue line) and skin point of the thyroid cartilage (green line) in the three anatomical axes: x-craniosacral (A) ylateral-lateral (B) and z-dorsoventral (C). Special types of Fig.s composed by a sequence of articulated segment graphs (D) were generated, representing a specific time at the beginning (E), middle (F) and final of swallowing (G). These articulated segments are formed by the union of three points (corresponding to the three sensors placed on the tongue: anterior, middle and posterior) through straight lines.CC-BY-NC · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Research works printed but not linked: 2

  1. [2]2. Barreto, J. F. Sistema estomatognático y esquema corporal. Colomb. Med., 30(4):173-80, 1999.
  2. [20]20. Okeson, J. P.; Sosa, G.; Bumann, A.; Bumann, U. & Lotzmann, U. Tratamiento de Oclusión y Afecciones Temporomandibulares. 5 th ed. Amsterdam, Elsevier, 2008.

Cited by

See all 6

Metadata

Authors
Fuentes, R., Dias, F., Álvarez, G., Lezcano, M. F., Farfán, C., Astete, N., & Arias, A.
Affiliations
Universidad de La Frontera (CL)
Corresponding author
Fuentes, Ramón
Venue
International journal of odontostomatology
Published
2018-03
Volume
12
Issue
1
Pages
105-112
ISSN
  • 0718-3801 (ISSN-L)
  • 0718-381X
OpenAlex
W2902430419
Cited by
5
References
21
Citations by year
2024: 1 · 2023: 2 · 2021: 1 · 2019: 1
FWCI
0.81
Type
journal article
Language
en
Open access
Licence
cc-by-nc
Locations
  • International journal of odontostomatology (publishedVersion, cc-by-nc)
  • LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (publishedVersion, other-oa)
  • Americanae (AECID Library) (submittedVersion, other-oa)
Funders
Universidad de La Frontera
Topics
  • Health Sciences › Dentistry › Oral Surgery › Temporomandibular Joint Disorders
  • Health Sciences › Dentistry › Orthodontics › Orthodontics and Dentofacial Orthopedics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
Keywords
stomatognathic system, mastication, swallowing, mandibular movement, saliva swallowing, water swallowing, recording protocols, reproducibility, oral physiology

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Application of 3D Electromagnetic Articulography in Dentistry: Mastication and Deglutition Analysis. Protocol Report. https://app.cochat.ai/papers/10.4067/s0718-381x2018000100105
The paper
Fuentes, R., Dias, F., Álvarez, G., Lezcano, M. F., Farfán, C., Astete, N., & Arias, A. (2018). Application of 3D Electromagnetic Articulography in Dentistry: Mastication and Deglutition Analysis. Protocol Report. International journal of odontostomatology. https://doi.org/10.4067/s0718-381x2018000100105

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.