Pilot Evaluation of a Novel Clinical Test of Reaction Time in National Collegiate Athletic Association Division I Football Players
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Context: Evidence suggests that concussion prolongs reaction time (RT). We have developed a simple, reliable clinical tool for measuring reaction time that may be of value in the assessment of concussion in athletes. Objective: To compare baseline values of clinical RT (RT clin) obtained using the new clinical reaction time apparatus with computerized RT (RT comp) obtained using a validated computerized neuropsychological test battery. Design: Cross-sectional study. Setting: Data were collected during a National Collegiate Athletic Association Division I collegiate football team's preparticipation physical examination session. Patients or Other Participants: Ninety-four Division I collegiate football players. Main Outcome Measure(s): The RT clin was measured using a 1.3-m measuring stick embedded in a weighted rubber disk that was released and caught as quickly as possible. The RT comp was measured using the simple RT component of CogState Sport. Results: For the 68 athletes whose CogState Sport tests passed the program's integrity check, RT clin and RT comp were correlated (r = 0.445, P < .001). Overall, mean RT clin was shorter and less variable than mean RT comp (203 ± 20 milliseconds versus 268 ± 44 milliseconds; P < .001). When RT clin and RT comp were compared between those athletes with (n = 68) and those without (n = 26) valid CogState Sport test sessions, mean RT clin was similar (202 ± 19 milliseconds versus 207 ± 23 milliseconds; P = .390), but mean RT comp was different (258 ± 35 milliseconds versus 290 ± 55 milliseconds; P = .009). Conclusions: The RT clin was positively correlated with RT comp and yielded more consistent reaction time values during baseline testing. Given that RT clin is easy to measure using simple, inexpensive equipment, further prospective study is warranted to determine its clinical utility in the assessment of concussion in athletes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Validity of ImPACT for measuring processing speed following sports-related concussion
Iverson, G. L., Lovell, M. R., & Collins, M. W. (2005) · Journal of Clinical and Experimental Neuropsychology · doi:10.1081/13803390490918435 · Cited by 278 · cited 2×
“11 These findings suggest that a Journal of Athletic Training 2010;45(4):327–332 g by the National Athletic Trainers’ Association, Inc www.”
Background
Cited by
Eckner, J. T., Kutcher, J. S., & Richardson, J. K. (2011) · Journal of Athletic Training · doi:10.4085/1062-6050-46.4.409 · Cited by 89
Self-citationWatanabe, H., Nakajima, K., Takagi, S., Mizuyama, R., Saito, M., Furusawa, K., Nakatani, K., Yokota, Y., Kataoka, H., Nakajima, H., et al. (2021) · Frontiers in Neuroergonomics · doi:10.3389/fnrgo.2021.644449 · Cited by 7
Montare, A. (2013) · Perceptual and Motor Skills · doi:10.2466/27.24.pms.116.3.796-805 · Cited by 6
Metadata
- Authors
- Eckner, J. T., Kutcher, J. S., & Richardson, J. K.
- Venue
- Journal of Athletic Training
- Published
- 2010-07
- Volume
- 45
- Issue
- 4
- Pages
- 327-332
- ISSN
- 1062-6050 (ISSN-L)
- OpenAlex
- W2089452848
- Cited by
- 131
- References
- 1
- FWCI
- 4.61
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pilot Evaluation of a Novel Clinical Test of Reaction Time in National Collegiate Athletic Association Division I Football Players. https://app.cochat.ai/papers/10.4085/1062-6050-45.4.327
- The paper
- Eckner, J. T., Kutcher, J. S., & Richardson, J. K. (2010). Pilot Evaluation of a Novel Clinical Test of Reaction Time in National Collegiate Athletic Association Division I Football Players. Journal of Athletic Training. https://doi.org/10.4085/1062-6050-45.4.327
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.