CoChat

Efficacy and Safety of Doxepin 1 mg, 3 mg, and 6 mg in Elderly Patients With Primary Insomnia: A Randomized, Double-Blind, Placebo-Controlled Crossover Study

Scharf, Martin, Rogowski, Roberta, Hull, Steven, Cohn, Martin, Mayleben, David, Feldman, Neil, Ereshefsky, Larry, Lankford, Alan, Roth, Thomas · 2008 · The Journal of Clinical Psychiatry
Cited by 111

The DOI matches its Crossref record.

Abstract

OBJECTIVES: Evaluate efficacy and safety of the histamine-H1 antagonist doxepin at doses of 1 mg, 3 mg, and 6 mg in elderly adults with primary insomnia. DESIGN: A randomized, double-blind, placebo-controlled, crossover design was used in this population of elderly adults with primary insomnia (DSM-IV). Each treatment period consisted of 2 polysomnographic (PSG) assessment nights with a 5- or 12-day drug-free interval between periods. The study was conducted from September 2004 to January 2005. SETTING: Sleep laboratories in 11 sleep centers in the United States. PARTICIPANTS: Elderly adults with primary insomnia. INTERVENTION: Doxepin 1 mg, 3 mg, and 6 mg. MEASUREMENTS: Efficacy was assessed using PSG and patient-reported measures. RESULTS: Seventy-six patients were randomly assigned. All 3 doxepin doses produced dose-related significant improvements in PSG-determined wake time during sleep (p < .0001), wake time after sleep onset (p < .0001), total sleep time (p < .0001), and overall sleep efficiency (p < .0001) versus placebo. At the 3-mg and 6-mg doses, sleep efficiency was significantly improved during all thirds of the night (p < .05). There was a dose-related decrease in patient-reported sleep latency, with the 6-mg dose achieving statistical significance in latency to sleep onset (p = .0181). The pattern of the remaining subjective efficacy results was consistent with PSG. All 3 doxepin doses had side effect profiles comparable to placebo, with no spontaneously reported anticholinergic effects, no memory impairment, and no significant next-day residual effects. CONCLUSIONS: In this 2-night study of elderly adults with primary insomnia, doxepin doses of 1 mg, 3 mg, and 6 mg were well tolerated and produced significant improvement in objective and subjective sleep maintenance and duration endpoints that persisted into the final hour of the night. Positive effects on patient-reported sleep onset were observed at the highest dose. All 3 doxepin doses had a safety profile comparable to placebo. These data demonstrate that doxepin was efficacious in improving sleep in elderly adults.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4088/jcp.v69n1005

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Scharf, M., Rogowski, R., Hull, S., Cohn, M., Mayleben, D., Feldman, N., Ereshefsky, L., Lankford, A., & Roth, T.
Venue
The Journal of Clinical Psychiatry
Published
2008-10-31
Volume
69
Issue
10
Pages
1557-1564
ISSN
0160-6689 (ISSN-L)
OpenAlex
W1992543303
Cited by
111
References
0
FWCI
14.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.