The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Optical coherence tomography angiography in retinal diseases
Open accessAbstract
Optical coherence tomography angiography (OCTA) is a new, non-invasive imaging system that generates volumetric data of retinal and choroidal layers. It has the ability to show both structural and blood flow information. Split-spectrum amplitude-decorrelation angiography (SSADA) algorithm (a vital component of OCTA software) helps to decrease the signal to noise ratio of flow detection thus enhancing visualization of retinal vasculature using motion contrast. Published studies describe potential efficacy for OCTA in the evaluation of common ophthalmologic diseases such as diabetic retinopathy, age related macular degeneration (AMD), retinal vascular occlusions and sickle cell disease. OCTA provides a detailed view of the retinal vasculature, which allows accurate delineation of microvascular abnormalities in diabetic eyes and vascular occlusions. It helps quantify vascular compromise depending upon the severity of diabetic retinopathy. OCTA can also elucidate the presence of choroidal neovascularization (CNV) in wet AMD. In this paper, we review the knowledge, available in English language publications regarding OCTA, and compare it with the conventional angiographic standard, fluorescein angiography (FA). Finally, we summarize its potential applications to retinal vascular diseases. Its current limitations include a relatively small field of view, inability to show leakage, and tendency for image artifacts. Further larger studies will define OCTA's utility in clinical settings and establish if the technology may offer a non-invasive option of visualizing the retinal vasculature, enabling us to decrease morbidity through early detection and intervention in retinal diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ranibizumab for Neovascular Age-Related Macular Degeneration
Rosenfeld, P. J., Brown, D. M., Heier, J. S., Boyer, D. S., Kaiser, P. K., Chung, C. Y., & Kim, R. Y. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa054481 · Cited by 5,886
Split-spectrum amplitude-decorrelation angiography with optical coherence tomography
Jia, Y., Tan, O., Tokayer, J., Potsaid, B., Wang, Y., Liu, J. J., Kraus, M. F., Subhash, H., Fujimoto, J. G., Hornegger, J., et al. (2012) · Optics Express · doi:10.1364/oe.20.004710 · Cited by 1,841
Spaide, R. F., Klancnik, J. M., & Cooney, M. J. (2015) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2014.3616 · Cited by 1,620
Optical Coherence Tomography Angiography of Optic Disc Perfusion in Glaucoma
Jia, Y., Wei, E., Wang, X., Zhang, X., Morrison, J. C., Parikh, M., Lombardi, L. H., Gattey, D. M., Armour, R. L., Edmunds, B., et al. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2014.01.021 · Cited by 740
Jia, Y., Bailey, S. T., Wilson, D. J., Tan, O., Klein, M. L., Flaxel, C. J., Potsaid, B., Liu, J. J., Lu, C. D., Kraus, M. F., et al. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2014.01.034 · Cited by 729
Risk factors associated with age-related macular degeneration
(2000) · Ophthalmology · doi:10.1016/s0161-6420(00)00409-7 · Cited by 633
Optical Coherence Tomography Angiography in Diabetic Retinopathy: A Prospective Pilot Study
Ishibazawa, A., Nagaoka, T., Takahashi, A., Omae, T., Tani, T., Sogawa, K., Yokota, H., & Yoshida, A. (2015) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2015.04.021 · Cited by 617
Takase, N., Nozaki, M., Kato, A., Ozeki, H., Yoshida, M., & Ogura, Y. (2015) · Retina · doi:10.1097/iae.0000000000000849 · Cited by 474
Agemy, S. A., Scripsema, N. K., Shah, C. M., Chui, T., Garcia, P. M., Lee, J. G., Gentile, R. C., Hsiao, Y.-S., Zhou, Q., Ko, T., et al. (2015) · Retina · doi:10.1097/iae.0000000000000862 · Cited by 472
Spectral-Domain Optical Coherence Tomography Angiography of Choroidal Neovascularization
de Carlo, T. E., Bonini Filho, M. A., Chin, A. T., Adhi, M., Ferrara, D., Baumal, C. R., Witkin, A. J., Reichel, E., Duker, J. S., & Waheed, N. K. (2015) · Ophthalmology · doi:10.1016/j.ophtha.2015.01.029 · Cited by 394
Cited by
Kashani, A. H., Chen, C.-L., Gahm, J. K., Zheng, F., Richter, G. M., Rosenfeld, P. J., Shi, Y., & Wang, R. K. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.07.002 · Cited by 1,006
Metadata
- Authors
- Chalam, K., & Sambhav, K.
- Venue
- Journal of Ophthalmic and Vision Research
- Publisher
- Knowledge E DMCC
- Published
- 2016
- Volume
- 11
- Issue
- 1
- Pages
- 84
- ISSN
- 2008-2010 (ISSN-L)
- 2008-322X
- OpenAlex
- W2341107052
- Cited by
- 261
- References
- 27
- FWCI
- 25.49
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical coherence tomography angiography in retinal diseases. https://app.cochat.ai/papers/10.4103/2008-322x.180709
- The paper
- Chalam, K., & Sambhav, K. (2016). Optical coherence tomography angiography in retinal diseases. Journal of Ophthalmic and Vision Research. https://doi.org/10.4103/2008-322x.180709
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.