The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Split-spectrum amplitude-decorrelation angiography with optical coherence tomography
Open accessAbstract
Amplitude decorrelation measurement is sensitive to transverse flow and immune to phase noise in comparison to Doppler and other phase-based approaches. However, the high axial resolution of OCT makes it very sensitive to the pulsatile bulk motion noise in the axial direction. To overcome this limitation, we developed split-spectrum amplitude-decorrelation angiography (SSADA) to improve the signal-to-noise ratio (SNR) of flow detection. The full OCT spectrum was split into several narrower bands. Inter-B-scan decorrelation was computed using the spectral bands separately and then averaged. The SSADA algorithm was tested on in vivo images of the human macula and optic nerve head. It significantly improved both SNR for flow detection and connectivity of microvascular network when compared to other amplitude-decorrelation algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The mechanics of human saccadic eye movement
Robinson, D. A. (1964) · The Journal of Physiology · doi:10.1113/jphysiol.1964.sp007485 · Cited by 893
Cited by
Takase, N., Nozaki, M., Kato, A., Ozeki, H., Yoshida, M., & Ogura, Y. (2015) · Retina · doi:10.1097/iae.0000000000000849 · Cited by 474
Hwang, T. S., Gao, S. S., Liu, L., Lauer, A. K., Bailey, S. T., Flaxel, C. J., Wilson, D. J., Huang, D., & Jia, Y. (2016) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2015.5658 · Cited by 389
Self-citationTan, G. S., Cheung, N., Simó, R., Cheung, G. C. M., & Wong, T. Y. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(16)30052-3 · Cited by 361
Spaide, R. F. (2015) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2015.04.012 · Cited by 313
Optical coherence tomography imaging for glaucoma - today and tomorrow
Leung, C. K.-S. (2016) · Asia-Pacific Journal of Ophthalmology · doi:10.1097/apo.0000000000000179 · Cited by 17
Metadata
- Authors
- Jia, Y., Tan, O., Tokayer, J., Potsaid, B., Wang, Y., Liu, J. J., Kraus, M. F., Subhash, H., Fujimoto, J. G., Hornegger, J., & Huang, D.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2012-02-09
- Volume
- 20
- Issue
- 4
- Pages
- 4710
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W1528934530
- Cited by
- 1,841
- References
- 1
- FWCI
- 23.37
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Split-spectrum amplitude-decorrelation angiography with optical coherence tomography. https://app.cochat.ai/papers/10.1364/oe.20.004710
- The paper
- Jia, Y., Tan, O., Tokayer, J., Potsaid, B., Wang, Y., Liu, J. J., Kraus, M. F., Subhash, H., Fujimoto, J. G., Hornegger, J., & Huang, D. (2012). Split-spectrum amplitude-decorrelation angiography with optical coherence tomography. Optics Express. https://doi.org/10.1364/oe.20.004710
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.