Point of care blood gases with electrolytes and lactates in adult emergencies

Open access
Kapoor, Dheeraj, Srivastava, Meghana, Singh, Pritam·2014·International Journal of Critical Illness and Injury Science

Abstract

Point-of-care testing (POCT) is one of the formidable concept introduce in the field of critical care settings to deliver decentralized, patient-centric health care to the patients. Rapid provision of blood measurements, particularly blood gases and electrolytes, may translate into improved clinical outcomes. Studies shows that POCT carries advantages of providing reduced therapeutic turnaround time (TTAT), shorter door-to-clinical-decision time, rapid data availability, reduced preanalytic and postanalytic testing errors, self-contained user-friendly instruments, small sample volume requirements, and frequent serial whole-blood testing. However, still there is a noticeable debate that exists among the laboratorians, clinicians, and administrators over concerns regarding analyzer inaccuracy, imprecision and performance (interfering substances), poorly trained non-laboratorians, high cost of tests, operator-dependent quality of testing, and difficulty in integrating test results with hospital information system (HIS). On search of literature using Medline/Pubmed and Embase using the key phrases "ppoint-of-care test," "central laboratory testing," "electrolytes," "blood gas analysis," "lactate," "emergency department," "intensive care unit," we found that POCT of blood gases and selected electrolytes may not entirely replace centralized laboratory testing but may transfigure the clinical practice paradigm of emergency and critical care physicians. We infer that further comprehensive, meaningful and rigorous evaluations are required to determine outcomes which are more quantifiable, closely related to testing events and are associated with effective cost benefits.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4103/2229-5151.141411

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Some earlier studies noted positive bias in POCT potassium readings, especially in hemolyzed samples.

    “However, some of these studies also noted positive bias in POCT readings, especially in hemolyzed samples [7,8].”

    From Reliability of Point-of-Care Venous Blood Gas Testing for Potassium and Sodium Compared to Central Laboratory Results in Emergency Patients: A Clinical Audit (2025) · cites this paper as [7]

    The Electrolytes > Sodium, Potassium, Chloride section reports that earlier studies found differences between POCT and central-laboratory potassium readings. It does not report positive bias or identify hemolyzed samples as a particular cause; the specific pediatric ICU study it discusses found underestimation instead. No page number is available in our copy. (LLM, conf=0.79)

    Experimental — accuracy not yet measured
  • Sodium underestimation patterns are supported by studies attributing discrepancies to differences in ion-selective electrode calibration, matrix effects, and ambient temperature and humidity.

    “These patterns are supported by studies such as Kapoor et al. [7] and Allardet-Servent et al. [8], who attribute these discrepancies to differences in ISE calibration, matrix effects, and the influence of ambient temperature and humidity on POCT devices.”

    From Reliability of Point-of-Care Venous Blood Gas Testing for Potassium and Sodium Compared to Central Laboratory Results in Emergency Patients: A Clinical Audit (2025) · cites this paper as Kapoor et al. [7]

    In the Electrolytes—Sodium, Potassium, Chloride section (page unavailable), the review reports sodium underestimation in a pediatric ICU study and says electrolyte discrepancies may reflect device calibrators, sample differences, and direct versus indirect ion-selective electrodes affected by proteins. It does not attribute the discrepancies to ambient temperature or humidity, and it presents the proposed causes cautiously rather than as established explanations. (LLM, conf=0.87)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

No references could be resolved yet.

Research works printed but not linked: 52

  1. [1]D’Orazio P Fogh-Andersen N Okorodudu A Shipp G Shirley T Toffaletti J Nichols JH Critical Care Chapter 5 Evidence Based Practice for Point-of-Care Testing: A National Academy of Clinical Biochemistry Laboratory Medicine Practice Guideline 2006 Washington DC AACC Press 30 43
  2. [2]Adekola OO Soriyan OO Meka I Akanmu ON Olanipekun S Oshodi TA The incidence of electrolyte and acid-base abnormalities in critically ill patients using point of care testing (i-STAT portable analyser) Nig Q J Hosp Med 2012 22 103 8 23175907
  3. [4]Lee EJ Shin SD Song KJ Kim SC Cho JS Lee SC A point-of-care chemistry test for reduction of turnaround and clinical decision time Am J Emerg Med 2011 29 489 95 20825817
  4. [5]Jose RJ Preller J Near-patient testing of potassium levels using arterial blood gas analysers: Can we trust these results? Emerg Med J 2008 25 510 3 18660404
  5. [7]Prause G Ratzenhofer-Komenda B Offner A Lauda P Voit H Pojer H Prehospital point of care testing of blood gases and electrolytes -an evaluation of IRMA Crit Care 1997 1 79 83 11056700 PMC28992
  6. [8]Jousi M Reitala J Lund V Katila A Leppäniemi A The role of pre-hospital blood gas analysis in trauma resuscitation World J Emerg Surg 2010 5 10 20412593 PMC2873276
  7. [9]Hinkelbein J Floss F Denz C Krieter H Accuracy and precision of three different methods to determine Pco2 (Paco2 vs. Petco2 vs. Ptcco2) during interhospital ground transport of critically ill and ventilated adults J Trauma 2008 65 10 8 18580512
  8. [10]Belpomme V Ricard-Hibon A Devoir C Dileseigres S Devaud ML Chollet C Correlation of arterial PCO2 and PETCO2 in prehospital controlled ventilation Am J Emerg Med 2005 23 852 9 16291440
  9. [11]Fermann GJ Suyama J Point of care testing in the emergency department J Emerg Med 2002 22 393 404 12113852
  10. [12]Nichols JH Christenson RH Clarke W Gronowski A Hammett-Stabler CA Jacobs E National Academy of Clinical Biochemistry Executive summary. The National Academy of Clinical Biochemistry Laboratory Medicine Practice Guideline: Evidence-based practice for point-of-care testing Clin Chim Acta 2007 379 14 28 17270169
  11. [13]Barquist E Pizzutiello M Burke M Bessey P Arterial blood gas analysis in the initial evaluation of the nonintubated adult blunt trauma patient J Trauma 2002 52 601 2 11901349
  12. [14]Chance JJ Li DJ Sokoll LJ Silberman MA Engelstad ME Nichols JH Multiple site analytical evaluation of a portable blood gas/electrolyte analyzer for point of care testing Crit Care Med 2000 28 2081 5 10890668
  13. [15]Jain A Subhan I Joshi M Comparison of the point-of-care blood gas analyzer versus the laboratory auto-analyzer for the measurement of electrolytes Int J Emerg Med 2009 2 117 20 20157454 PMC2700230
  14. [16]Flegar-Mestric Z Perkov S Comparability of point of care whole blood electrolyte and substrate testing using a Stat Profile Critical Care Xpress analyzer and standard laboratory methods Clin Chem Lab Med 2006 44 898 903 16776641
  15. [17]Thomas FO Hoffman TL Handrahan DL Crapo RO Snow G The measure of treatment agreement between portable and laboratory blood gas measurements in guiding protocol-driven ventilator management J Trauma 2009 67 303 13 19667883
  16. [18]Drenk N Point of care testing in critical care medicine: The clinician's view Clin Chim Acta 2001 307 3 7 11369329
  17. [19]Adekola OO Irurhe NK Meka IA Akanmu NO Menkiti ID Udenze IC The agreement of point-of-care and standard laboratory electrolyte and glucose analysis in critically ill patients in a sub-Saharan tertiary teaching hospital Nig Q J Hosp Med 2013 23 58 64 24579497
  18. [20]Winkelman JW Wybenga DR Quantification of medical and operational factors determining central versus satellite laboratory testing of blood gases Am J Clin Pathol 1994 102 7 10 8037170
  19. [21]Kilgore ML Steindel SJ Smith JA Evaluating stat testing options in an academic health center: Therapeutic turnaround time and staff satisfaction Clin Chem 1998 44 1597 603 9702944
  20. [22]Giuliano KK Grant ME Blood analysis at the point of care: Issues in application for use in critically ill patients AACN Clin Issues 2002 13 204 20 12011593
  21. [23]Chacko B Peter JV Patole S Fleming JJ Selvakumar R Electrolytes assessed by point-of-care testing - Are the values comparable with results obtained from the central laboratory? Indian J Crit Care Med 2011 15 24 9 21633542 PMC3097538
  22. [24]Chhapola V Kanwal SK Sharma R Kumar V A comparative study on reliability of point of care sodium and potassium estimation in a pediatric intensive care unit Indian J Pediatr 2013 80 731 5 23392748
  23. [25]Morimatsu H Rocktäschel J Bellomo R Uchino S Goldsmith D Gutteridge G Comparison of point-of-care versus central laboratory measurement of electrolyte concentrations on calculations of the anion gap and the strong ion difference Anesthesiology 2003 98 1077 84 12717128
  24. [26]Asimos AW Gibbs MA Marx JA Jacobs DG Erwin RJ Norton HJ Value of point-of-care blood testing in emergent trauma management J Trauma 2000 48 1101 8 10866258
  25. [27]Prichard JS French JS Alvar N Clinical evaluation of the ABL-77 for point-of-care analysis in the cardiovascular operating room J Extra Corpor Technol 2006 38 128 33 16921685 PMC4680748
  26. [28]Cox CJ Acute care testing. Blood gases and electrolytes at the point of care Clin Lab Med 2001 21 321 35 11396086
  27. [29]King RI Mackay RJ Florkowski CM Lynn AM Electrolytes in sick neonates–which sodium is the right answer? Arch Dis Child Fetal Neonatal Ed 2012 98 F74 6 22215801
  28. [30]Yip PM Chan MK Zielinski N Adeli K Heparin interference in whole blood sodium measurements in a pediatric setting Clin Biochem 2006 39 391 5 16443209
  29. [31]Zivin JR Gooley T Zager RA Ryan MJ Hypocalcemia: A pervasive metabolic abnormality in the critically ill Am J Kidney Dis 2001 37 689 98 11273867
  30. [32]Zaloga GP Hypocalcemic crisis Crit Care Clin 1991 7 191 200 2007214
  31. [33]Choi YC Hwang SY The value of initial ionized calcium as a predictor of mortality and triage tool in adult trauma patients J Korean Med Sci 2008 23 700 5 18756060 PMC2526411
  32. [34]Ha¨stbacka J Pettila¨ V Prevalence and predictive value of ionized hypocalcemia among critically ill patients Acta Anaesthesiol Scand 2003 47 1264 9 14616325
  33. [35]Maier JD Levine SN Hypercalcemia in the Intensive Care Unit: A Review of Pathophysiology, Diagnosis, and Modern Therapy J Intensive Care Med 2013 24130250
  34. [36]Ward RT Colton DM Meade PC Henry JC Contreras LM Wilson OM Serum levels of calcium and albumin in survivors versus nonsurvivors after critical injury J Crit Care 2004 19 54 64 15101007
  35. [37]Houston M The role of magnesium in hypertension and cardiovascular disease J Clin Hypertens (Greenwich) 2011 13 843 7 22051430 PMC8108907
  36. [38]Kupetsky-Rincon EA Uitto J Magnesium: Novel applications in cardiovascular disease-a review of the literature Ann Nutr Metab 2012 61 102 10 22907037
  37. [39]González W Altieri PI Alvarado S Banchs HL Escobales N Crespo M Magnesium: The forgotten electrolyte Bol Asoc Med P R 2013 105 17 20 24282915
  38. [40]Cortés YE Moses L Magnesium disturbances in critically ill patients Compend Contin Educ Vet 2007 29 420 7 17727050
  39. [42]Vanavanan S Chittamma A Performance of a multi-profile critical care testing analyzer Clin Chem Lab Med 2008 46 9 14 17663637
  40. [43]Silverman RA Osborn H Runge J Gallagher EJ Chiang W Feldman J Acute Asthma Magnesium Study Group IV magnesium sulfate in the treatment of acute severe asthma: A multicenter randomized controlled trial Chest 2002 122 489 97 12171821
  41. [44]Rivers E Nguyen B Havstad S Essler J Muzzin A Knoblich B Early Goal-Directed Therapy Collaborative Group Early goal-directed therapy in the treatment of severe sepsis and septic shock N Engl J Med 2001 345 1368 77 11794169
  42. [45]Moore CC Jacob ST Pinkerton R Meya DB Mayanja-Kizza H Reynolds SJ Point-of-care lactate testing predicts mortality of severe sepsis in a predominantly HIV type 1-infected patient population in Uganda Clin Infect Dis 2008 46 215 22 18171253
  43. [46]Soliman HM Vincent JL Prognostic value of admission serum lactate concentration in intensive care unit patients Acta Clin Belg 2010 65 176 81 20669785
  44. [47]Borthwick HA Brunt LK Mitchem KL Chaloner C Does lactate measurement performed on admission predict clinical outcome on the intensive care unit? A concise systematic review Ann Clin Biochem 2012 49 391 4 22715295
  45. [48]Martin J Blobner M Busch R Moser N Kochs E Luppa PB Point-of-care testing on admission to the intensive care unit: Lactate and glucose independently predict mortality Clin Chem Lab Med 2013 51 405 12 22987833
  46. [49]Rossi AF Khan DM Hannan R Bolivar J Zaidenweber M Burke R Goal-directed medical therapy and point-of-care testing improve outcomes after congenital heart surgery Intensive Care Med 2005 31 98 104 15650863
  47. [50]Jansen TC van Bommel J Schoonderbeek FJ Sleeswijk Visser SJ van der Klooster JM Lima AP LACTATE study group Early lactate-guided therapy in intensive care unit patients: A multicenter, open-label, randomized controlled trial Am J Respir Crit Care Med 2010 182 752 61 20463176
  48. [51]Boldt J Kumle B Suttner S Haisch G Point-of-care (POC) testing of lactate in the intensive care patient: Accuracy, reliability, and costs of different measurement systems Acta Anaesthesiol Scand 2001 45 194 9 11167165
  49. [52]Beneteau-Burnat B Pernet P Pilon A Latour D Goujon S Feuillu A Evaluation of the GEM Premier 4000: A compact blood gas CO-Oximeter and electrolyte analyzer for point-of-care and laboratory testing Clin Chem Lab Med 2008 46 271 9 18076351
  50. [53]Karon BS Scott R Burritt MF Santrach PJ Comparison of lactate values between point-of-care and central laboratory analyzers Am J Clin Pathol 2007 128 168 71 17580286
  51. [54]Leino A Kurvinen K Interchangeability of blood gas, electrolyte and metabolite results measured with point-of-care, blood gas and core laboratory analyzers Clin Chem Lab Med 2011 49 1187 91 21504373
  52. [55]De Koninck AS De Decker K Van Bocxlaer J Meeus P Van Hoovels L Analytical performance evaluation of four cartridge-type blood gas analyzers Clin Chem Lab Med 2012 50 1083 91 22706251

Cited by

Sorted by citations

Authors
Kapoor, D., Srivastava, M., & Singh, P.
Affiliations
Government Medical College and Hospital (IN)
Corresponding author
Kapoor, Dheeraj
Venue
International Journal of Critical Illness and Injury Science
Published
2014
Volume
4
Issue
3
Pages
216
ISSN
2229-5151 (ISSN-L)
OpenAlex
W2020637779
Cited by
49
References
0
Citations by year
2026: 2 · 2025: 7 · 2024: 2 · 2023: 7 · 2022: 6 · 2021: 5 · 2020: 3 · 2019: 7 · 2017: 4 · 2016: 2 · 2015: 4
FWCI
2.22
Type
journal article
Language
en
Open access
Licence
cc-by-nc-sa
Locations
  • International Journal of Critical Illness and Injury Science (publishedVersion)
  • PubMed Central (publishedVersion, cc-by-nc-sa)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Clinical Biochemistry › Bacterial Identification and Susceptibility Testing
  • Health Sciences › Medicine › Epidemiology › Sepsis Diagnosis and Treatment
Keywords
point-of-care testing, blood gas analysis, electrolytes, lactate, emergency department, intensive care, centralized laboratory testing, turnaround time, hospital information system integration, cost-benefit analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review