Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 12Adrenal Hormones and DisordersClinical Laboratory Practices and Quality ControlStress Responses and Cortisol

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

The 1 μg cosyntropin test in normal individuals: A reappraisal

Open access
Anantharaman, R, Menezes, Geraldine, Yusuf, Razif, Ganapathi, B, Ayyar, SVageesh, Srinivasan, R·2013·Indian Journal of Endocrinology and Metabolism

Abstract

BACKGROUND: The 1μg cosyntropin test has some advantages over the 250μg test as a test of adrenal function. One of the concerns regarding the 1 μg test includes stability of the cosyntropin when reconstituted and stored. Classically the 5(th) percentile responses to cosyntropin in normal individuals have been used to define a normal response. Recent studies have shown that these normative values should be determined for individual assays. MATERIALS AND METHODS: We performed a 1μg cosyntropin test using reconstituted and refrigerated (4-8(°) C) cosyntropin in saline solution in 49 non pregnant adults who were apparently healthy and had no exposure to exogenous glucocorticoids. The cosyntropin solution was stored for up to 60 days following reconstitution. We analysed the data for any association between duration of cosyntropin solution storage and the cortisol responses to cosyntropin administration. RESULTS: The mean ± SD cortisol level at baseline, 30 and 60 min were-12.19 ± 3 μg/dl, 20.72 ± 2.63 μg/dl, 16.86 ± 3.33 μg/dl. The 5(th) percentile cortisol response at 30 min was 16.5 μg/dl (16.33 μg/dl rounded off). The correlation coefficients between number of days of cosyntropin solution storage and the cortisol responses at 30 and 60 min were (Spear mans rho = 0.06,-0.24 respectively) (P = 0.69 and 0.41). There were no differences in cortisol values whether the storage was for less than 30 days or more than 30 days (mean difference 0.25 μg/dl P = 0.44). CONCLUSION: The 5(th) percentile normative values determined for our assay is lower than what is currently being used clinically and in research publications. Prolonged refrigerated storage of cosyntropin solution does not affect the validity of the 1 μg cosyntropin test.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4103/2230-8210.113763

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 The age distribution of studied subjects
Figure 1 The age distribution of studied subjectsCC BY-NC-SA · PubMed Central
Figure 2 Mean and 95% CI values of coristol at baseline,30 min and 60 min
Figure 2 Mean and 95% CI values of coristol at baseline,30 min and 60 minCC BY-NC-SA · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Research works printed but not linked: 2

  1. Nyunt, 2010, Normal Cortisol Response on Low-Dose Synacthen (1 μg) Test in Children with Prader Willi Syndrome, J Clin Endocrinol Metab, E464
  2. Gonzalbez, 2000, Establishment of reference values for standard dose short synacthen test (250 microgram), low dose short synacthen test (1 microgram) and insulin tolerance test for assessment of the hypothalamo-pituitary-adrenal axis in normal subjects, Clin Endocrinol (Oxf), 199

Cited by

See all 12

Metadata

Authors
Anantharaman, R., Menezes, G., Yusuf, R., Ganapathi, B., Ayyar, S., & Srinivasan, R.
Affiliations
St.John's Medical College Hospital (IN)
Corresponding author
Anantharaman, R
Venue
Indian Journal of Endocrinology and Metabolism
Published
2013
Volume
17
Issue
4
Pages
693
ISSN
2230-8210 (ISSN-L)
OpenAlex
W2090670539
Cited by
12
References
15
Citations by year
2024: 3 · 2023: 2 · 2022: 1 · 2020: 2 · 2018: 1 · 2016: 1 · 2015: 2
FWCI
0.79
Type
journal article
Language
en
Open access
Licence
cc-by-nc-sa
Locations
  • Indian Journal of Endocrinology and Metabolism (publishedVersion, cc-by-nc-sa)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-sa)
  • PubMed Central (publishedVersion, cc-by-nc-sa)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Adrenal Hormones and Disorders
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Life Sciences › Neuroscience › Behavioral Neuroscience › Stress Responses and Cortisol
Keywords
cortisol response, adrenal function testing, reference values, cold storage, healthy adults

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review