Cited by 3Obstructive Sleep Apnea ResearchNasal Surgery and Airway StudiesSinusitis and nasal conditions

Effectiveness of septoplasty with or without inferior turbinate reduction in patients with obstructive sleep apnea

Open access
Abd El_Wahab, SamahG, Abd El-Aziz, AymanE, Abd El-Fattah, AymanA, El-Habashy, MahmoudM, Omar, HossamA·2018·The Egyptian Journal of Chest Diseases and Tuberculosis

Abstract

Objective To assess the results of traditional septoplasty with or without partial reduction of the inferior turbinate of patients with obstructive sleep apnea (OSA) owing to a rhinogenic cause. Background Sleep-related breathing disorders and obstructive sleep apnea particularly still on a growing interest in diagnosis and treatment modalities. Patients and methods This was a prospective study that included 60 patients who had obstructive sleep apnea and had a significant nasal obstruction. It was carried out at Otorhinolaryngology and Chest Department in El-Menoufia University Hospital during the period between 20 January 2016 and 1 July 2017. A written consent was taken from all patients. A polysomnography was planned before surgery and 3 months after surgery for all patients. The consequence of these two specific surgeries on sleep-related variables was evaluated and compared. Results In group A, which was subjected to septoplasty with turbinectomy, the apnea–hypopnea index showed a significant reduction (16.333±3.03 and 13.5700±4.2; P=0.001) compared with group B, which was subjected to septoplasty alone. The other variables (neck circumference and BMI) were still unchanged. Subjective assessments obtained with Epworth sleepiness scale preoperatively and postoperatively showed a significant reduction in the mean. The P value of group A was 0.005 and group B was 0.003. Conclusion The intranasal surgery has a good effect on the subjective quality of sleep in OSA patients, and that there might be an added effect on AHI in selected patients with both septal deviation and hypertrophy of the inferior turbinates.

Integrity signals

Registry

Crossref · 10.4103/ejcdt.ejcdt_5_18

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Abd El_Wahab, S., Abd El-Aziz, A., Abd El-Fattah, A., El-Habashy, M., & Omar, H.
Affiliations
Menoufia University (EG)
Venue
The Egyptian Journal of Chest Diseases and Tuberculosis
Published
2018
Volume
67
Issue
3
Pages
295
ISSN
0422-7638 (ISSN-L)
OpenAlex
W4240830457
Cited by
3
References
12
Citations by year
2026: 1 · 2025: 1 · 2022: 1
FWCI
0.00
Type
journal article
Language
en
Open access
Licence
cc-by-nc-sa
Locations
  • Egyptian Journal of Chest Diseases and Tuberculosis (publishedVersion, cc-by-nc-sa)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Medicine › Physiology › Obstructive Sleep Apnea Research
  • Health Sciences › Medicine › Surgery › Nasal Surgery and Airway Studies
  • Health Sciences › Medicine › Otorhinolaryngology › Sinusitis and nasal conditions
Keywords
obstructive sleep apnea, septoplasty, inferior turbinate reduction, turbinectomy, nasal obstruction, septal deviation, inferior turbinate hypertrophy, apnea-hypopnea index, Epworth Sleepiness Scale, polysomnography, intranasal surgery

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review