Implementing the DICOM Standard for Digital Pathology
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
BACKGROUND: ) is the standard for the representation, storage, and communication of medical images and related information. A DICOM file format and communication protocol for pathology have been defined; however, adoption by vendors and in the field is pending. Here, we implemented the essential aspects of the standard and assessed its capabilities and limitations in a multisite, multivendor healthcare network. METHODS: We selected relevant DICOM attributes, developed a program that extracts pixel data and pixel-related metadata, integrated patient and specimen-related metadata, populated and encoded DICOM attributes, and stored DICOM files. We generated the files using image data from four vendor-specific image file formats and clinical metadata from two departments with different laboratory information systems. We validated the generated DICOM files using recognized DICOM validation tools and measured encoding, storage, and access efficiency for three image compression methods. Finally, we evaluated storing, querying, and retrieving data over the web using existing DICOM archive software. RESULTS: Whole slide image data can be encoded together with relevant patient and specimen-related metadata as DICOM objects. These objects can be accessed efficiently from files or through RESTful web services using existing software implementations. Performance measurements show that the choice of image compression method has a major impact on data access efficiency. For lossy compression, JPEG achieves the fastest compression/decompression rates. For lossless compression, JPEG-LS significantly outperforms JPEG 2000 with respect to data encoding and decoding speed. CONCLUSION: Implementation of DICOM allows efficient access to image data as well as associated metadata. By leveraging a wealth of existing infrastructure solutions, the use of DICOM facilitates enterprise integration and data exchange for digital pathology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ehteshami Bejnordi, B., Veta, M., Johannes van Diest, P., van Ginneken, B., Karssemeijer, N., Litjens, G., van der Laak, J. A. W. M., and the CAMELYON16 Consortium, Hermsen, M., Manson, Q. F., et al. (2017) · JAMA · doi:10.1001/jama.2017.14585 · Cited by 3,293
OpenSlide: A vendor-neutral software foundation for digital pathology
Goode, A., Gilbert, B., Harkes, J., Jukic, D., & Satyanarayanan, M. (2013) · Journal of Pathology Informatics · doi:10.4103/2153-3539.119005 · Cited by 546
Mukhopadhyay, S., Feldman, M. D., Abels, E., Ashfaq, R., Beltaifa, S., Cacciabeve, N. G., Cathro, H. P., Cheng, L., Cooper, K., Dickey, G. E., et al. (2018) · American Journal of Surgical Pathology · doi:10.1097/pas.0000000000000948 · Cited by 399 · cited 1×
“Regulatory hurdles in the United States can, in part, be held historically accountable;[6] however, the US Federal Drug Administration recently cleared the first whole slide imaging system for marketing[6] based on a recent multisite clinical trial (NCT02699970) that demonstrated noninferiority to optical microscopy a…”
BackgroundOverview of telepathology, virtual microscopy, and whole slide imaging: Prospects for the future
Weinstein, R. S., Graham, A. R., Richter, L. C., Barker, G. P., Krupinski, E. A., Lopez, A. M., Erps, K. A., Bhattacharyya, A. K., Yagi, Y., & Gilbertson, J. R. (2009) · Human Pathology · doi:10.1016/j.humpath.2009.04.006 · Cited by 380 · cited 1×
“[1] First, scanned slides may be navigated seamlessly on a display at multiple magnifications for diagnosis and research (“virtual microscopy”).[2] Second, different pathologists may remotely review the slides simultaneously in real time (“telepathology”).”
BackgroundThe Orthanc Ecosystem for Medical Imaging
Jodogne, S. (2018) · Journal of Digital Imaging · doi:10.1007/s10278-018-0082-y · Cited by 93 · cited 1×
“[28,69] In the interim, to support the installed based of scanners – only capable of producing proprietary format images, commercial and open-source implementers have begun to develop conversion tools.[70,71] To evaluate the capabilities and limitations of DICOM for the representation of digital pathology whole slide…”
MethodDICOMweb™: Background and Application of the Web Standard for Medical Imaging
Genereaux, B. W., Dennison, D. K., Ho, K., Horn, R., Silver, E. L., O’Donnell, K., & Kahn, C. E. (2018) · Journal of Digital Imaging · doi:10.1007/s10278-018-0073-z · Cited by 48
Cited by
Towards a guideline for evaluation metrics in medical image segmentation
Müller, D., Soto-Rey, I., & Kramer, F. (2022) · BMC Research Notes · doi:10.1186/s13104-022-06096-y · Cited by 668
“slide or scan into multiple smaller images) are often also applied to reduce complexity and class imbalance [2, 20].”
BackgroundAbels, E., Pantanowitz, L., Aeffner, F., Zarella, M. D., van der Laak, J., Bui, M. M., Vemuri, V. N., Parwani, A. V., Gibbs, J., Agosto‐Arroyo, E., et al. (2019) · The Journal of Pathology · doi:10.1002/path.5331 · Cited by 459
Deep Learning for Whole Slide Image Analysis: An Overview
Dimitriou, N., Arandjelović, O., & Caie, P. D. (2019) · Frontiers in Medicine · doi:10.3389/fmed.2019.00264 · Cited by 332
Brancato, V., Esposito, G., Coppola, L., Cavaliere, C., Mirabelli, P., Scapicchio, C., Borgheresi, R., Neri, E., Salvatore, M., & Aiello, M. (2024) · Journal of Translational Medicine · doi:10.1186/s12967-024-04891-8 · Cited by 106
“Based on the compelling need for data standardization and interoperability in digital pathology, there are ongoing efforts for the standardization of the representation and storage of pathology image data and analysis results [101, 102].”
BackgroundRadiology and multi-scale data integration for precision oncology
Paverd, H., Zormpas-Petridis, K., Clayton, H., Burge, S., & Crispin-Ortuzar, M. (2024) · npj Precision Oncology · doi:10.1038/s41698-024-00656-0 · Cited by 41
Metadata
- Authors
- Herrmann, M. D., Clunie, D. A., Fedorov, A., Doyle, S. W., Pieper, S., Klepeis, V., Le, L. P., Mutter, G. L., Milstone, D. S., Schultz, T. J., Kikinis, R., Kotecha, G. K., Hwang, D. H., Andriole, K. P., lafrate, A. J., Brink, J. A., Boland, G. W., Dreyer, K. J., Michalski, M., Golden, J. A., Louis, D. N., & Lennerz, J. K.
- Venue
- Journal of Pathology Informatics
- Publisher
- Elsevier BV
- Published
- 2018-01
- Volume
- 9
- Issue
- 1
- Pages
- 37
- ISSN
- 2153-3539 (ISSN-L)
- OpenAlex
- W2905969903
- Cited by
- 155
- References
- 6
- FWCI
- 6.65
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implementing the DICOM Standard for Digital Pathology. https://app.cochat.ai/papers/10.4103/jpi.jpi_42_18
- The paper
- Herrmann, M. D., Clunie, D. A., Fedorov, A., Doyle, S. W., Pieper, S., Klepeis, V., Le, L. P., Mutter, G. L., Milstone, D. S., Schultz, T. J., Kikinis, R., Kotecha, G. K., Hwang, D. H., Andriole, K. P., lafrate, A. J., Brink, J. A., Boland, G. W., Dreyer, K. J., Michalski, M., . . . Lennerz, J. K. (2018). Implementing the DICOM Standard for Digital Pathology. Journal of Pathology Informatics. https://doi.org/10.4103/jpi.jpi_42_18
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.