Simulation of IEC 61850-based substations under OMNeT++
Abstract
Communication systems are essential components within the Smart Grids. Given the complexity of real world communication systems, advanced simulation platforms are required to facilitate the study, analysis, design and evaluation of such systems. The IEC 61850 is one of the most relevant communicati
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The T1-1 case study is normally used as a reference for a substation that transforms voltage levels from 220 kV to 132 kV.
“This case study is normally used as a reference for a substation that transforms voltage levels from 220 kV to 132 kV [13-15].”
From Real-Time Analysis of Time-Critical Messages in IEC 61850 Electrical Substation Communication Systems (2019) · cites this paper as [13]
Cited by
Sorted by citations
León, H., Montez, C., Valle, O., & Vasques, F. (2019) · Energies · doi:10.3390/en12122272 · Cited by 35 · see citing works
“[13] proposes simulation models for the OMNeT++/INETMANET framework to support IEC 61850 based communication.”
BackgroundMethodInfluential
- Authors
- Juárez, J., Rodríguez-Morcillo, C., & Rodríguez-Mondéjar, J. A.
- ORCID
- Juárez, Javier
- Venue
- Proceedings of the Fifth International Conference on Simulation Tools and Techniques
- Publisher
- ACM
- Published
- 2012
- OpenAlex
- W4242184017
- Cited by
- 9
- References
- 0
- Citations by year
- 2025: 1 · 2023: 1 · 2021: 1 · 2019: 1 · 2018: 1 · 2016: 1 · 2014: 3
- FWCI
- 1.23
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- International ICST Conference on Simulation Tools and Techniques (SIMUTools) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Systems and Technologies
- Physical Sciences › Engineering › Control and Systems Engineering › Simulation and Modeling Applications
- Physical Sciences › Engineering › Control and Systems Engineering › Smart Grid Security and Resilience
- Keywords
- IEC 61850, smart grid communication, substation communication, OMNeT++, communication system simulation, power system communication
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review