A Device for Dried Blood Microsampling in Quantitative Bioanalysis: Overcoming The Issues Associated Blood Hematocrit
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
AIMS: A cross-laboratory experiment has been performed on a novel dried blood sampler in order to investigate whether it overcomes issues associated with blood volume and hematocrit (HCT) that are observed when taking a subpunch from dried blood spot samples. MATERIALS & METHODS: An average blood volume of 10.6 μl was absorbed by the samplers across the different HCTs investigated (20-65%). RESULTS: No notable change of volume absorbed was noted across the HCT range. Furthermore, the variation in blood sample volumes across six different laboratories was within acceptable limits. CONCLUSION: The novel volumetric absorptive microsampling device has the potential to deliver the advantages of dried blood spot sampling while overcoming some of the issues associated with the technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dried Blood Spot Methods in Therapeutic Drug Monitoring: Methods, Assays, and Pitfalls
Edelbroek, P. M., Heijden, J. V. D., & Stolk, L. M. L. (2009) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0b013e31819e91ce · Cited by 512
Spooner, N., Lad, R., & Barfield, M. (2009) · Analytical Chemistry · doi:10.1021/ac8022839 · Cited by 433
Self-citationDenniff, P., & Spooner, N. (2014) · Analytical Chemistry · doi:10.1021/ac5022562 · Cited by 396
Self-citationBarfield, M., Spooner, N., Lad, R., Parry, S., & Fowles, S. (2008) · Journal of Chromatography B · doi:10.1016/j.jchromb.2008.05.025 · Cited by 273
Self-citationCapiau, S., Stove, V. V., Lambert, W. E., & Stove, C. P. (2012) · Analytical Chemistry · doi:10.1021/ac303014b · Cited by 157
Timmerman, P., White, S., Cobb, Z., de Vries, R., Thomas, E., & van Baar, B. L. M. (2013) · Bioanalysis · doi:10.4155/bio.13.173 · Cited by 113
Spooner, N., Ramakrishnan, Y., Barfield, M. D., Dewit, O., & Miller, S. L. (2010) · Bioanalysis · doi:10.4155/bio.10.105 · Cited by 49
Self-citationRahavendran, S. V., Vekich, S., Skor, H. E., Batugo, M. R., Nguyen, L., Shetty, B. V., & Shen, Z. (2012) · Bioanalysis · doi:10.4155/bio.12.85 · Cited by 47
Discenza, L., Obermeier, M. T., Westhouse, R. A., Olah, T. V., & D’Arienzo, C. J. (2012) · Bioanalysis · doi:10.4155/bio.12.69 · Cited by 13
Cited by
Capiau, S., Veenhof, H., Koster, R. A., Bergqvist, Y., Boettcher, M., Halmingh, O., Keevil, B. G., Koch, B. C. P., Linden, R., Pistos, C., et al. (2019) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0000000000000643 · Cited by 321
Is the hematocrit still an issue in quantitative dried blood spot analysis?
Velghe, S., Delahaye, L., & Stove, C. P. (2019) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2018.10.010 · Cited by 204
van den Broek, I., Fu, Q., Kushon, S., Kowalski, M. P., Millis, K., Percy, A., Holewinski, R. J., Venkatraman, V., & Van Eyk, J. E. (2017) · Clinical Mass Spectrometry · doi:10.1016/j.clinms.2017.08.004 · Cited by 62
Self-citation
Metadata
- Authors
- Spooner, N., Denniff, P., Michielsen, L., De Vries, R., Ji, Q. C., Arnold, M. E., Woods, K., Woolf, E. J., Xu, Y., Boutet, V., Zane, P., Kushon, S., & Rudge, J. B.
- Venue
- Bioanalysis
- Publisher
- Informa UK Limited
- Published
- 2014-12-16
- Volume
- 7
- Issue
- 6
- Pages
- 653-659
- ISSN
- 1757-6180 (ISSN-L)
- 1757-6199
- OpenAlex
- W2152575430
- Cited by
- 217
- References
- 9
- FWCI
- 7.78
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.