Comparison of 3 Algorithms for Basal Insulin in Transitioning from Intravenous to Subcutaneous Insulin in Stable Patients after Cardiothoracic Surgery
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Objective The objective was to determine the efficacy of an algorithim containing aspart dosed according to carbohydrate intake and one of 3 initial doses of detemir in stable cardiac surgery patients requiring intravenous (IV) insulin. Methods Patients were extubated, off pressors and otherwise stable, requiring at least 1 unit/hr of IV insulin at least 48 hours following surgery. Subjects were randomized to once daily detemir at 50, 65, or 80% of IV basal insulin requirements and received aspart according to carbohydrate intake. The dose of detemir was adjusted daily over 72 hours. Results The number of patients with an initial morning glucose 80–130 mg/dl was 36, 63, and 56% of patients at the 50, 65, and 80% doses (p=0.12) (n=82). However, the mean overall glucose at 24 and 72 hours was similar between groups, and 86, 93, and 92% achieved a mean glucose 80–180 mg/dl at 72 hours (p=0.60). Hypoglycemia (<65 mg/dl) only occurred in the 65% (21%) and 80% (12%) groups over the first 72 hours (p=0.02 in the 50% compared to the 65 and 80% groups combined) with one event <40 mg/dl in the 80% group. There was no loss of glycemic control by the end of the once daily dosing interval. Conclusions Glycemic targets can be achieved without hypoglycemia by 72 hours in most cardiac surgery patients requiring IV insulin with a regimen containing an initial detemir dose of 50% of basal IV insulin requirements and prandial and supplemental insulin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Umpierrez, G. E., Smiley, D., Zisman, A., Prieto, L. M., Palacio, A., Ceron, M., Puig, A., & Mejia, R. (2007) · Diabetes Care · doi:10.2337/dc07-0295 · Cited by 671
Cited by
Hsia, E., Seggelke, S., Gibbs, J., Hawkins, R. M., Cohlmia, E., Rasouli, N., Wang, C., Kam, I., & Draznin, B. (2012) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-1244 · Cited by 112
Perioperative management of hyperglycemia and diabetes in cardiac surgery patients
Galindo, R. J., Fayfman, M., & Umpierrez, G. E. (2018) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2017.10.005 · Cited by 95
“Thus, it is recommended to monitor glucose values every 1 hours to 2 hours and to adjust insulin infusion rates accordingly.(85) Insulin infusion should be continued until clinical and hemodynamic stability has been achieved, until patients are tolerating oral intake or receiving nutritional support, and after several…”
BackgroundTransitioning safely from intravenous to subcutaneous insulin
Kreider, K. E., & Lien, L. F. (2015) · Current Diabetes Reports · doi:10.1007/s11892-015-0595-4 · Cited by 36
Transition from intravenous to subcutaneous insulin in critically ill adults
Doolin, M. K., Walroth, T. A., Harris, S. A., Whitten, J. A., & Fritschle-Hilliard, A. C. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816629985 · Cited by 13
“These results are consistent with the findings of Dungan and colleagues.(13) Despite the high rate of goal achievement in the 50-59% group, only 9 of the 100 (9%) patients were transitioned via this strategy.”
BackgroundResultInfluentialZhou, K., Buehler, L. A., Zaw, T., Bena, J., & Lansang, M. C. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2021.10.003 · Cited by 3
Metadata
- Authors
- Dungan, K., Hall, C., Schuster, D., & Osei, K.
- Venue
- Endocrine Practice
- Publisher
- Elsevier BV
- Published
- 2011-09
- Volume
- 17
- Issue
- 5
- Pages
- 753-758
- ISSN
- 1530-891X (ISSN-L)
- OpenAlex
- W1967775031
- Cited by
- 21
- References
- 1
- FWCI
- 1.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.