Abstract
Objective Controversy persists regarding the use of the low-dose adrenocorticotropic hormone (ACTH) stimulation test (LDST) for the diagnosis of adrenal insufficiency (AI) and optimal test result interpretation. However, many centers are now using the LDST to assess cortisol secretion adequacy, and some only use a 30-minute cortisol level to determine adrenal sufficiency or AI. This study examined both 30- and 60-minute cortisol levels to assess whether the interpretation of the test was affected when both cortisol levels were taken into consideration. Methods Data were obtained by retrospective chart review from a single pediatric endocrinology unit over a 7-year period. We identified 82 patients who completed the LDST. Their mean age was 11.7 years, and 37% were female. Cortisol levels were evaluated at baseline and 30 and 60 minutes after cosyntropin administration. A cutoff value ≥18 μg/dL was used to define adrenal sufficiency. Results We found that 54% of patients reached peak cortisol levels at 60 minutes, and 11 patients who did not pass the test at 30 minutes did so at 60 minutes. The only predictive characteristic was weight status; overweight and obese individuals tended to peak at 30 minutes, and normal and underweight individuals tended to peak at 60 minutes. Conclusion Although further studies are necessary to confirm our findings, it appears that measuring cortisol both 30 and 60 minutes following synthetic ACTH administration may be necessary to avoid overdiagnosing AI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Nevertheless, the latest evidence suggests that although the majority of patients peak 30 min after the stimulus, measuring cortisol both 30 and 60 min is necessary to reduce the risk of false positives and overdiagnosis of adrenal insufficiency.”
From ACTH Stimulation Test for the Diagnosis of Secondary Adrenal Insufficiency: Light and Shadow (2023) · cites this paper as [31]
In the citing paper
“Indeed, from 10 to 24% of patients, according to several studies, classified as AI based on the 30-min cortisol level are reclassified as adrenally sufficient if the 60-min cortisol level is performed [31,32].”
From ACTH Stimulation Test for the Diagnosis of Secondary Adrenal Insufficiency: Light and Shadow (2023) · cites this paper as [31]
In the citing paper
“The same group found that a 30-min cortisol level above or below 12.7 μg /dL (350 nmol/L) across the first ACTH Test after TNS best predicts HPA axis recovery, enabling early identification of subgroups more likely to recover and hence patients to be prioritized for retesting [31].”
From ACTH Stimulation Test for the Diagnosis of Secondary Adrenal Insufficiency: Light and Shadow (2023) · cites this paper as [31]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Corticotropin tests for hypothalamic-pituitary- adrenal insufficiency: a metaanalysis
Kazlauskaite, R., Evans, A. T., Villabona, C. V., Abdu, T. A. M., Ambrosi, B., Atkinson, A. B., Choi, C. H., Clayton, R. N., Courtney, C. H., Gonc, E. N., et al. (2008) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2008-0710 · Cited by 385
Diagnosis of Adrenal Insufficiency
Dorin, R. I., Qualls, C. R., & Crapo, L. M. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-139-3-200308050-00009 · Cited by 374
Presentation of primary adrenal insufficiency in childhood
Hsieh, S., & White, P. C. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2011-0015 · Cited by 131
Purnell, J. Q., Kahn, S. E., Samuels, M. H., Brandon, D., Loriaux, D. L., & Brunzell, J. D. (2009) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.90769.2008 · Cited by 112
Suliman, A. M., Smith, T. P., Labib, M., Fiad, T. M., & McKenna, T. J. (2002) · Clinical Endocrinology · doi:10.1046/j.1365-2265.2002.01509.x · Cited by 75 · cited 1×
“For this study, we used a cortisol value ≥18 μg/dL (500 nmol/L) following cosyntropin administration to define adrenal sufficiency (1,7-9), and also utilized ≥16 μg/dL (10) and ≥20 μg (11) to compare various definitions for adrenal sufficiency found in the literature.”
MethodFrequency of hypoglycemia in children with adrenal insufficiency
Artavia-Loria, E., Chaussain, J. L., Bougnères, P. F., & Job, J. C. (1986) · Acta Endocrinologica · doi:10.1530/acta.0.112s275 · Cited by 40
Research works printed but not linked: 11
- Tordjman, 1995, The role of the low dose (1 microgram) adrenocorticotropin test in the evaluation of patients with pituitary diseases, J Clin Endocrinol Metab, 80, 1301
- Dickstein, 1991, Adrenocorticotropin stimulation test: effects of basal cortisol level, time of day, and suggested new sensitive low dose test, J Clin Endocrinol Metab, 72, 773, 10.1210/jcem-72-4-773 · DOI · Paper page
- Weintrob, 1998, Standard and low-dose short adrenocorticotropin test compared with insulin-induced hypoglycemia for assessment of the hypothalamic-pituitary-adrenal axis in children with idiopathic multiple pituitary hormone deficiencies, J Clin Endocrinol Metab, 83, 88, 10.1210/jcem.83.1.4496 · DOI
- Choi, 2002, Use of the low-dose corticotropin stimulation test for the diagnosis of secondary adrenal insufficiency, Hong Kong Med J, 8, 427
- Rasmuson, 1996, A low dose ACTH test to assess the function of the hypothalamic-pituitary-adrenal axis, Clin Endocrinol (Oxf), 44, 151, 10.1046/j.1365-2265.1996.600482.x · DOI · Paper page
- Abdu, 1999, Comparison of the low dose short synacthen test (1 microg), the conventional dose short synacthen test (250 microg), and the insulin tolerance test for assessment of the hypothalamo-pituitary- adrenal axis in patients with pituitary disease, J Clin Endocrinol Metab, 84, 838
- Cho, 2014, Different cut-off values of the insulin tolerance test, the high-dose short Synacthen test (250 μg) and the low-dose short Synacthen test (1 μg) in assessing central adrenal insufficiency, Clin Endocrinol (Oxf), 81, 77, 10.1111/cen.12397 · DOI
- Maghnie, 2005, evaluation of adrenal function in patients with growth hormone deficiency and hypothalamic-pituitary disorders: comparison between insulin-induced hypoglycemia, low-dose ACTH, standard ACTH and CRH stimulation tests, Eur J Endocrinol, 152, 735, 10.1530/eje.1.01911 · DOI
- Kuczmarski, 2000, CDC growth charts: United States, Adv Data, 8, 1
- Reinehr, 2014, Relationships between 24-hour urinary free cortisol concentrations and metabolic syndrome in obese children, J Clin Endocrinol Metab, 99, 2391, 10.1210/jc.2013-4398 · DOI
- Hill, 2011, The association between morning cortisol and adiposity in children varies by weight status, J Pediatr Endocrinol Metab, 24, 709, 10.1515/JPEM.2011.267 · DOI
Cited by
ACTH Stimulation Test for the Diagnosis of Secondary Adrenal Insufficiency: Light and Shadow
Birtolo, M. F., Antonini, S., Saladino, A., Zampetti, B., Lavezzi, E., Chiodini, I., Mazziotti, G., Lania, A. G. A., & Cozzi, R. (2023) · Biomedicines · doi:10.3390/biomedicines11030904 · Cited by 19
Metadata
- Authors
- Cartaya, J., & Misra, M.
- Venue
- Endocrine Practice
- Publisher
- Elsevier BV
- Published
- 2015-05
- Volume
- 21
- Issue
- 5
- Pages
- 508-513
- ISSN
- 1530-891X
- PMC
- PMC4442480
- Cited by
- 23
- References
- 6
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Low-Dose Acth Stimulation Test: is 30 Minutes Long Enough? https://app.cochat.ai/papers/10.4158/ep14423.or
- The paper
- Cartaya, J., & Misra, M. (2015). The Low-Dose Acth Stimulation Test: is 30 Minutes Long Enough? Endocrine Practice. https://doi.org/10.4158/ep14423.or
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.