iRFP is a sensitive marker for cell number and tumor growth in high-throughput systems
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
GFP and luciferase are used extensively as markers both in vitro and in vivo although both have limitations. The utility of GFP fluorescence is restricted by high background signal and poor tissue penetrance. Luciferase throughput is limited in vitro by the requirement for cell lysis, while in vivo, luciferase readout is complicated by the need for substrate injection and the dependence on endogenous ATP. Here we show that near-infrared fluorescent protein in combination with widely available near-infrared scanners overcomes these obstacles and allows for the accurate determination of cell number in vitro and tumor growth in vivo in a high-throughput manner and at negligible per-well costs. This system represents a significant advance in tracking cell proliferation in tissue culture as well as in animals, with widespread applications in cell biology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serine starvation induces stress and p53-dependent metabolic remodelling in cancer cells
Maddocks, O. D. K., Berkers, C. R., Mason, S. M., Zheng, L., Blyth, K., Gottlieb, E., & Vousden, K. H. (2013) · Nature · doi:10.1038/nature11743 · Cited by 1,007 · cited 1×
“Mice were housed in sterile IVC cages, monitored thrice weekly, and killed humanely when tumors reached clinical endpoint of predetermined size (volume = [length × width(2)]/2) or ulceration as previously described.(6) All animal work was approved by Ethical Review Process (University of Glasgow) and undertaken in lin…”
MethodSelf-citation
Cited by
Tardito, S., Oudin, A., Ahmed, S. U., Fack, F., Keunen, O., Zheng, L., Miletic, H., Sakariassen, P. Ø., Weinstock, A., Wagner, A., et al. (2015) · Nature Cell Biology · doi:10.1038/ncb3272 · Cited by 557
Self-citationNear-Infrared Fluorescent Proteins, Biosensors, and Optogenetic Tools Engineered from Phytochromes
Chernov, K. G., Redchuk, T. A., Omelina, E. S., & Verkhusha, V. V. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00700 · Cited by 264
A Role for p53 in the Adaptation to Glutamine Starvation through the Expression of SLC1A3
Tajan, M., Hock, A. K., Blagih, J., Robertson, N. A., Labuschagne, C. F., Kruiswijk, F., Humpton, T. J., Adams, P. D., & Vousden, K. H. (2018) · Cell Metabolism · doi:10.1016/j.cmet.2018.07.005 · Cited by 230
Self-citationCancer-Specific Loss of p53 Leads to a Modulation of Myeloid and T Cell Responses
Blagih, J., Zani, F., Chakravarty, P., Hennequart, M., Pilley, S., Hobor, S., Hock, A. K., Walton, J. B., Morton, J. P., Gronroos, E., et al. (2020) · Cell Reports · doi:10.1016/j.celrep.2019.12.028 · Cited by 173
“In order to track accurately and in an unbiased fashion in vivo tumor growth, KC and KFC cells were engineered to express nearinfrared fluorescent protein (iRFP) (Hock et al., 2014; Shcherbakova and Verkhusha, 2013) (Figure 1F).”
BackgroundSelf-citationp53‐mediated adaptation to serine starvation is retained by a common tumour‐derived mutant
Humpton, T. J., Hock, A. K., Maddocks, O. D. K., & Vousden, K. H. (2018) · Cancer & Metabolism · doi:10.1186/s40170-018-0191-6 · Cited by 58
Self-citation
Metadata
- Authors
- Hock, A. K., Lee, P., Maddocks, O. D., Mason, S. M., Blyth, K., & Vousden, K. H.
- Venue
- Cell Cycle
- Publisher
- Informa UK Limited
- Published
- 2013-10-31
- Volume
- 13
- Issue
- 2
- Pages
- 220-226
- ISSN
- 1538-4101 (ISSN-L)
- 1551-4005
- OpenAlex
- W2001375582
- Cited by
- 36
- References
- 1
- FWCI
- 1.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.