Comprehensive tracking of host cell proteins during monoclonal antibody purifications using mass spectrometry
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
An advanced two-dimensional liquid chromatography/mass spectrometry platform was used to quantify individual host cell proteins (HCPs) present at various purification steps for several therapeutic monoclonal antibodies (mAbs) produced in Chinese hamster ovary cells. The methodology produced reproducible identifications and quantifications among replicate analyses consistent with a previously documented individual limit of quantification of ~13 ppm. We were able to track individual HCPs from cell culture fluid to protein A eluate pool to subsequent viral inactivation pool and, in some cases, further downstream. Approximately 500 HCPs were confidently identified in cell culture fluid and this number declined progressively through the purification scheme until no HCPs could be confidently identified in polishing step cation-exchange eluate pools. The protein A eluate pool of nine different mAbs contained widely differing numbers, and total levels, of HCPs, yet the bulk of the total HCP content in each case consisted of a small subset of normally intracellular HCPs highly abundant in cell culture fluid. These observations hint that minimizing cell lysis during cell culture/harvest may be useful in minimizing downstream HCP content. Clusterin and actin are abundant in the protein A eluate pools of most mAbs studied. HCP profiling by this methodology can provide useful information to process developers and lead to the refinement of existing purification platforms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Absolute Quantification of Proteins by LCMSE
Silva, J. C., Gorenstein, M. V., Li, G.-Z., Vissers, J. P. C., & Geromanos, S. J. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500230-mcp200 · Cited by 1,529
Dominguez, R., & Holmes, K. C. (2011) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-042910-155359 · Cited by 1,211
Cited by
Host cell protein testing by ELISAs and the use of orthogonal methods
Zhu‐Shimoni, J., Yu, C., Nishihara, J., Wong, R. M., Gunawan, F., Lin, M., Krawitz, D., Liu, P., Sandoval, W., & Vanderlaan, M. (2014) · Biotechnology and Bioengineering · doi:10.1002/bit.25327 · Cited by 188
“Zhang et al. (2014) studied several therapeutic monoclonal antibodies (mAbs) produced in CHO using a two-dimensional liquid chromatography combined mass spectrometry approach.”
MethodMonitoring process-related impurities in biologics–host cell protein analysis
Pilely, K., Johansen, M. R., Lund, R. R., Kofoed, T., Jørgensen, T. K., Skriver, L., & Mørtz, E. (2022) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03648-2 · Cited by 78
Goey, C. H., Tsang, J. M. H., Bell, D., & Kontoravdi, C. (2017) · Biotechnology and Bioengineering · doi:10.1002/bit.26437 · Cited by 39
Zhang, Z., Albanetti, T., Linkous, T., Larkin, C. J., Schoner, R., McGivney, J. B., & Dovichi, N. J. (2017) · ELECTROPHORESIS · doi:10.1002/elps.201600390 · Cited by 23
Metadata
- Authors
- Zhang, Q., Goetze, A. M., Cui, H., Wylie, J., Trimble, S., Hewig, A., & Flynn, G. C.
- Venue
- mAbs
- Publisher
- Informa UK Limited
- Published
- 2014-02-11
- Volume
- 6
- Issue
- 3
- Pages
- 659-670
- ISSN
- 1942-0862 (ISSN-L)
- 1942-0870
- OpenAlex
- W2023805450
- Cited by
- 131
- References
- 2
- FWCI
- 5.23
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.