Preventive Use of Noninvasive Ventilation After Extubation: A Prospective, Multicenter Randomized Controlled Trial
The DOI matches its Crossref record.
Abstract
BACKGROUND: The effectiveness of noninvasive ventilation (NIV) after extubation in preventing post-extubation respiratory failure is still controversial. METHODS: We conducted a prospective, multicenter randomized controlled study involving patients on mechanical ventilation for > 48 hours who tolerated a 2-hour spontaneous breathing trial and were subsequently extubated. The patients were randomized to NIV or standard medical therapy. Re-intubation rate within 72 hours was the primary outcome measure. Multivariable logistic regression analysis was used to determine predictors for extubation failure. RESULTS: We randomized 406 patients to either NIV (no. = 202) or standard medical therapy (no. = 204). The 2 groups had similar baseline clinical characteristics. There were no differences in extubation failure (13.2% in control and 14.9% in NIV), intensive care unit or hospital mortality. Cardiac failure was a more common cause of extubation failure in control than in NIV. There was no difference in rapid shallow breathing index (RSBI) in extubation failure patients between control (80) and NIV (73). When using data from all patients, we found Acute Physiology and Chronic Health Evaluation (APACHE II) scores (odds ratio [OR] 1.13, 95% CI 1.07-1.20, P < .001), maximal inspiratory pressure (OR 1.04, 95% CI 1.00-1.08, P = .03), and RSBI (OR 1.03, 95% CI 1.02-1.05, P < .001) to be predictors of extubation failure. Abundant secretions were the most common reason (35.1%) for extubation failure identified by attending physicians. CONCLUSIONS: Preventive use of NIV after extubation in patients who passed spontaneous breathing trial did not show benefits in decreasing extubation failure rate or the mortality rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Official ERS/ATS clinical practice guidelines: noninvasive ventilation for acute respiratory failure
Rochwerg, B., Brochard, L., Elliott, M. W., Hess, D., Hill, N. S., Nava, S., Navalesi, P., Antonelli, M., Brozek, J., Conti, G., et al. (2017) · European Respiratory Journal · doi:10.1183/13993003.02426-2016 · Cited by 1,668
The Decision to Extubate in the Intensive Care Unit
Thille, A. W., Richard, J.-C. M., & Brochard, L. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201208-1523ci · Cited by 576
Egi, M., Ogura, H., Yatabe, T., Atagi, K., Inoue, S., Iba, T., Kakihana, Y., Kawasaki, T., Kushimoto, S., Kuroda, Y., et al. (2021) · Journal of Intensive Care · doi:10.1186/s40560-021-00555-7 · Cited by 224
Ha, T. S., Oh, D. K., Lee, H.-J., Chang, Y., Jeong, I. S., Sim, Y. S., Hong, S.-K., Park, S., Suh, G. Y., & Park, S. Y. (2024) · Tuberculosis and Respiratory Diseases · doi:10.4046/trd.2024.0039 · Cited by 3
Metadata
- Authors
- Su, C.-L., Chiang, L.-L., Yang, S.-H., Lin, H.-Y., Cheng, K.-C., Huang, Y.-C. T., & Wu, C.-P.
- Venue
- Respiratory Care
- Publisher
- SAGE Publications
- Published
- 2012-02-01
- Volume
- 57
- Issue
- 2
- Pages
- 204-210
- ISSN
- 0020-1324 (ISSN-L)
- OpenAlex
- W2154452972
- Cited by
- 95
- References
- 0
- FWCI
- 6.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Preventive Use of Noninvasive Ventilation After Extubation: A Prospective, Multicenter Randomized Controlled Trial. https://app.cochat.ai/papers/10.4187/respcare.01141
- The paper
- Su, C.-L., Chiang, L.-L., Yang, S.-H., Lin, H.-Y., Cheng, K.-C., Huang, Y.-C. T., & Wu, C.-P. (2012). Preventive Use of Noninvasive Ventilation After Extubation: A Prospective, Multicenter Randomized Controlled Trial. Respiratory Care. https://doi.org/10.4187/respcare.01141
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.