The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Humidified High Flow Nasal Oxygen During Respiratory Failure in the Emergency Department: Feasibility and Efficacy
Abstract
OBJECTIVE: Heated and humidified high flow nasal cannula oxygen therapy (HFNC) represents a new alternative to conventional oxygen therapy that has not been evaluated in the emergency department (ED). We aimed to study its feasibility and efficacy in patients exhibiting acute respiratory failure presenting to the ED. METHODS: Prospective, observational study in a university hospital's ED. Patients with acute respiratory failure requiring > 9 L/min oxygen or with ongoing clinical signs of respiratory distress despite oxygen therapy were included. The device of oxygen administration was then switched from non-rebreathing mask to HFNC. Dyspnea, rated by the Borg scale and a visual analog scale, respiratory rate, and S(pO(2)) were collected before and 15, 30, and 60 min after beginning HFNC. Feasibility was assessed through caregivers' acceptance of the device in terms of practicality and perceived effect on the subjects, evaluated by questionnaire. RESULTS: Seventeen subjects, median age 64 y (46-84.7 y), were studied. Pneumonia was the most common reason for oxygen therapy (n = 9). HFNC was associated with a significant decrease in both dyspnea scores: Borg scale from 6 (5-7) to 3 (2-4) (P < .001), and visual analog scale from 7 (5-8) to 3 (1-5) (P < .01). Respiratory rate decreased from 28 breaths/min (25-32 breaths/min) to 25 breaths/min (21-28 breaths/min) (P < .001), and S(pO(2)) increased from 90% (88.5-94%) to 97% (92.5-100%) (P < .001). Fewer subjects exhibited clinical signs of respiratory distress (10/17 vs 3/17, P = .03). HFNC was well tolerated and no adverse event was noted. Altogether, 76% of healthcare givers declared preferring HFNC, as compared to conventional oxygen therapy. CONCLUSIONS: HFNC is possible in the ED, and it alleviated dyspnea and improved respiratory parameters in subjects with acute hypoxemic respiratory failure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Respiratory rate predicts cardiopulmonary arrest for internal medicine inpatients.
Fieselmann, J. F., Hendryx, M. S., Helms, C. M., & Wakefield, D. S. (1993) · Journal of General Internal Medicine · doi:10.1007/bf02600071 · Cited by 399 · cited 2×
“RR decreased from 28 (25-32) to 25 (21-28) bpm (p<0.”
BackgroundHodgetts, T. J., Kenward, G., Vlachonikolis, I. G., Payne, S., & Castle, N. (2002) · Resuscitation · doi:10.1016/s0300-9572(02)00100-4 · Cited by 355
Cited by
Patel, A., & Nouraei, S. A. R. (2015) · Anaesthesia · doi:10.1111/anae.12923 · Cited by 825
Failure of high-flow nasal cannula therapy may delay intubation and increase mortality
Kang, B. J., Koh, Y., Lim, C.-M., Huh, J. W., Baek, S., Han, M., Seo, H.-S., Suh, H. J., Seo, G. J., Kim, E. Y., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3693-5 · Cited by 657
Physiologic Effects of High-Flow Nasal Cannula in Acute Hypoxemic Respiratory Failure
Mauri, T., Turrini, C., Eronia, N., Grasselli, G., Volta, C. A., Bellani, G., & Pesenti, A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201605-0916oc · Cited by 641
Roca, O., Messika, J., Caralt, B., García-de-Acilu, M., Sztrymf, B., Ricard, J.-D., & Masclans, J. R. (2016) · Journal of Critical Care · doi:10.1016/j.jcrc.2016.05.022 · Cited by 512
Self-citationNishimura, M. (2016) · Respiratory Care · doi:10.4187/respcare.04577 · Cited by 476
Metadata
- Authors
- Lenglet, H., Sztrymf, B., Leroy, C., Brun, P., Dreyfuss, D., & Ricard, J.-D.
- Venue
- Respiratory Care
- Publisher
- SAGE Publications
- Published
- 2012-11-01
- Volume
- 57
- Issue
- 11
- Pages
- 1873-1878
- ISSN
- 0020-1324 (ISSN-L)
- OpenAlex
- W2112108807
- Cited by
- 201
- References
- 2
- FWCI
- 13.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.