Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 241

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

High-Flow Oxygen Administration by Nasal Cannula for Adult and Perinatal Patients

Ward, Jeffrey J · 2013 · Respiratory Care

Abstract

The nasal cannula has been a commonly used patient interface to provide supplemental oxygen since its introduction in the 1940s. Traditionally, it has been categorized as a low-flow device and capable of delivering a 0.4 F(IO(2)) with flows up to 6 L/min to adults with normal minute ventilation. However, there is considerable performance variability among patients and design, which results in an exponential decline in delivered F(IO(2)) as breathing frequencies increase. The nasal cannula has also been successfully adapted for use in perinatal and pediatric respiratory care; flows are reduced, in the range of 0.25-1 L/min, due to smaller minute volumes. A decade or so ago, high-flow nasal cannula (HFNC) oxygen therapy was introduced, accompanied by heated humidification systems to prevent the associated drying of upper airway mucosa and to increase patient comfort. Therapeutic flows for adults were in the 15-40 L/min range; F(IO(2)) could be independently adjusted with air/O(2) blending. The HFNC has also found additional clinical application in perinatal care, as delivery systems with flows > 2 L/min could create a distending pressure similar to nasal CPAP. There is a small but growing body of information from clinical trials that supports use of HFNC as an alternative oxygen interface for adults who present with moderate hypoxemia that persists after receiving oxygen by reservoir-bag masks or similar therapy. Clinical observations report greater patient acceptance and comfort versus oxygen masks. HFNC therapy has also been considered valuable in perinatal care in treating the respiratory distress syndrome or supporting patients after extubation similar to nasal CPAP. At present, research-based evidence for the role of HFNC for its perinatal applications remains unclear. This review will identify proposed mechanisms for therapeutic effectiveness, current delivery equipment, guidelines for rational patient application, and direction for further research.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4187/respcare.01941

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 241

Metadata

Authors
Ward, J. J.
Venue
Respiratory Care
Published
2013-01-01
Volume
58
Issue
1
Pages
98-122
ISSN
0020-1324 (ISSN-L)
OpenAlex
W2156882712
Cited by
241
References
1
FWCI
17.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-Flow Oxygen Administration by Nasal Cannula for Adult and Perinatal Patients. https://app.cochat.ai/papers/10.4187/respcare.01941
The paper
Ward, J. J. (2013). High-Flow Oxygen Administration by Nasal Cannula for Adult and Perinatal Patients. Respiratory Care. https://doi.org/10.4187/respcare.01941

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.