CoChat

CPAP Adherence of Patients With Obstructive Sleep Apnea

Open access
Salepci, Banu, Caglayan, Benan, Kiral, Nesrin, Parmaksiz, Elif Torun, Comert, Sevda Sener, Sarac, Gulsen, Fidan, Ali, Gungor, Gulten Aktin · 2013 · Respiratory Care
Cited by 84

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Continuous positive airway pressure (CPAP) and bi-level positive airway pressure (BPAP) are the gold standard treatments for obstructive sleep apnea syndrome (OSAS), but CPAP/BPAP is not well tolerated and requires long-term follow-up. OBJECTIVE: We prospectively assessed subjective and objective adherence and factors that affect adherence in OSAS patients. METHODS: Subjects using CPAP/BPAP were questioned about adverse effects of CPAP/BPAP and were assessed with the Epworth Sleepiness Scale (ESS) at the first, third, sixth, and twelfth month, and once every 6 months after the first year. CPAP/BPAP use and objective and subjective adherence were assessed. Subjects who used CPAP/BPAP for at least 4 hours per night for at least 70% of the days monitored were regarded as adherent, and those who did not were considered non-adherent. The relationships between adherence and demographic data, polysomnography findings, ESS scores, and adverse effects were statistically analyzed. RESULTS: Six-hundred forty-eight subjects who were diagnosed with OSAS by polysomnography and accepted to use CPAP/BPAP in our sleep center between January 2005 and June 2011 were included. Four-hundred fifty-one subjects (69.6%) were men, and 197 (30.4%) were women. Two-hundred forty-eight (38.3%) subjects attended follow-ups, 246 (37.9%) were called by telephone, and 154 (23.8%) could not be reached. Of the whole population, 63.9% had obtained their CPAP/BPAP machine. In the 248 subjects who attended follow-ups, subjective adherence was 85.1% and objective adherence was 64.5%. Improvement in ESS score (P < .001) and satisfactory sleep (P < .001) were found to be significantly higher in the adherent group. Chest discomfort, difficulty falling asleep, and sleep disturbances were significantly higher in the non-adherent group (all P < .01). CONCLUSIONS: Of the whole population, just 38.3% attended follow-ups. The objective adherence was lower than the subjective adherence in subjects who attended follow-ups. Younger subjects were more adherent, and the most important factors that correlated with adherence were substantial improvement of daytime sleepiness and effect of CPAP/BPAP on satisfactory sleep. CONCLUSIONS: CPAP/BPAP adherence should be followed with objective monitoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4187/respcare.02139

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 84

Metadata

Authors
Salepci, B., Caglayan, B., Kiral, N., Parmaksiz, E. T., Comert, S. S., Sarac, G., Fidan, A., & Gungor, G. A.
Venue
Respiratory Care
Published
2013-09-01
Volume
58
Issue
9
Pages
1467-1473
ISSN
0020-1324 (ISSN-L)
OpenAlex
W2108889424
Cited by
84
References
13
FWCI
2.86
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: CPAP Adherence of Patients With Obstructive Sleep Apnea. https://app.cochat.ai/papers/10.4187/respcare.02139
The paper
Salepci, B., Caglayan, B., Kiral, N., Parmaksiz, E. T., Comert, S. S., Sarac, G., Fidan, A., & Gungor, G. A. (2013). CPAP Adherence of Patients With Obstructive Sleep Apnea. Respiratory Care. https://doi.org/10.4187/respcare.02139

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.